HomeMy WebLinkAbout2351 WESTMINSTER AVE - Building Permits CITY OF COSTA MESA a
44,411W) BUILDING DIVISION
DEVELOPMENT SERVICES DEPARTMENT PERMIT NU BER
ji4 iPERMIT
"�� B -01578
(714)754-5273 • Fax(714)754-4856 • www.ci.costa-mesa.ca.us 77 FAIR DRIVE,COSTA MESA,CA 92626
BUILDING PERMIT
Job Address: 2351 WESTMINSTER AV Status: ISSUED
Suite: Applied: 09/10/2004
Vicinity: WINDOWS AND EXTERIOR DOORS Issued: 09/10/2004
Parcel Number: 11913113 Zoning:
Applicant: COLEMAN, RODNEY E ISSUED BY: /n —
Address: 3341 MARYLAND CIR
Phone: 909-620-1997
COSTA MESA,CA Zip: 92626
Owner COLEMAN, RODNEY E
Address 3341 MARYLAND CIR
Phone:
COSTA MESA,CA Zip: 92626
Contractor: OWNER-BUILDER
Address:
Phone:
Zip: License: 000000
Arch : Eng:
Address: Address:
Phone: Phone:
Zip: License: License:
SCOPE OF PERMIT
REPLACEMENT OF 10 WINDOWS(LIKE-FOR-LIKE)'AND THE FRONT AND REAR DOOR TO AN EXISTING SFD.
NO OTHER WORK AUTHORIZED WITH THIS PERMIT.
FEE SUMMARY
Plan Check: $0.00 Calc Valuation: $2,000.00
Permit: $69.25 Claim Valuation: $2,000.00
SMIP Res: $0.50
SMIP Corn: $0.00
Other: $0.00
Inspection: $0.00
Total: $69.75
PLANNING &ZONING
SETBACKS,
MAIN STRUCTURE Front 0-0 Rear 0-0 Left 0-0 Right 0-0
ACCESSORY Front 0-0 Rear 0-0 Left 0-0 Right 0-0
PARKING Existing: 0 Required: 0 Proposed: 0
NOTICE: The work authorized by this permit shall comply with all applicable handicap access requirements under California statutes and related
regulations.(Ord.No.92-28,§1, 12-21-92)
EXPIRATION: This permit shall automatically expire and become void if work is not commenced within 180 days,or if work is suspended or abandoned
for a period of 180 days.
INSPECTIONS: In order for the work authorized under this permit to be considered legal, such work must comply with all applicable codes, and all
required Inspections and final approval must be obtained.Failure to obtain inspections and final approval will result in the expiration of this permit.
FOR INSPECTIONS CALL: (714)754-5626
2446-46(WOO)
WORKERS'COMPENSATION DECLARATION:
I hereby affirm under penalty of perjury one of the following declarations:
❑ I have and will maintain a certificate of consent to self-Insure for workers'compensation,as provided for by section 3700 of the Labor Code,for the performance of the
work for which this permit is issued.
❑ I have and will maintain workers'compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work for which this permit is issued.
My workers'compensation Insurance carrier and policy number are:
Carrier: Policy Number:
(This section need not be completed/t the permit is valued et one hundred dollars($100)or less.)
I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California,and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall forthwith
comply with these pGroJ•��ns.
Applicant Signature: 0- P iC * -c r. Date: -ld-0
WARNING:FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED
THOUSAND DOLLARE($100,000),IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES.
LICENSED CONTRACTORS DECLARATION:
I hereby affirm that I am licensed under provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code,and my license is in full
force and effect.Lic.# Class#
Contractors Signature: Date:
CONSTRUCTION LENDING AGENCY:
❑ 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued,(Sec.3097,Civil Code).
Lender's Name: Lender's Address:
Signature: Date:
OWNER-BUILDER DECLARATIONS:
I hereby affirm that under penalty of perjury that I am EXEMPT FROM THE CONTRACTORS LICENSE LAW for the following reason(Sec.7031.5,Business and Professions'
Code:Any city or county which requires a permit to construct,alter,improve,demolish,or repair any structure,prior to Its issuance,also requires the applicant for such permit
to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the
Business and Professions Code)or that he or she Is exempt therefrom and the basis for the alleged exemption.Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars($500).):
❑ I,as owner of the properly,or my employees with wages as their sole compensation,WILL DO THE WORK,and the structure is not Intended or offered for sale(Sec.
7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon,and who does such work
himself or herself or through his or her own employees,provided that such improvements are not Intended or offered for sale.If,however,the building or improvement is
sold within one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for purpose of sale.). '
❑ I,as owner of the property,am EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS to construct the project(Sec.7044,Business and Professions
Code:The contractors License Law does not apply to an owner of property who builds or Improves thereon,and who contracts for such project with a contractor(s)
. license pursuant to the Contractors License Laws.).
❑ I am ex•,e1' 'der sec. �/ Business and Professions Code for this reason:
Signature: r/, i �/J!i/ — Date: t/' -��
Owner I•verified by drivers license. Ayes 0 No Driver's License No. Expires: 3 -Q g
Verification of Ownership by(type of document,eni.e.-property tax bill or deed):
DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION:
❑ I hereby certify that no excavation five(5)or more feet in depth into which a person is required to descend,will be made in connection with work authorized by this
permit,and that no building structure,scaffolding,falsework,or demolition or dismantling thereof,will be more than thirty-six(36)feet high.(Chap.3.2,Grp 2,Art 2,Sec.
341,Title 8,California Administrative Code).
❑ As owner-builder, I will not employ anyone to do work which would require a permit from the Division of Industrial Safety,as noted above, unless such person has a
permit to do such work from the division.
Signature: Date:
Division of Industrial Safety Permit Number:
HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION:
1 Will the applicant or present or future building occupant need to file and certify a Business Plan for emergency response to release or threatened release of a hazardous
material? 0 Yes 0 No
(Section 25505 of the Califomia Health and Safety Code requires,with some exceptions,that a Business Plan be filed with the Costa Mesa Fire Department by every
business which has at any one time during a reported year a quantity of hazardous materials equal to or greater than a weight of 500 pounds,or a volume of 55 gallons,
or 200 cubic feet of compressed gas at standard temperature and pressure). _ _ _
2 Does or will the applicant or present or future building occupant need to file a registration form for acutely hazardous materials? ❑Yes 0 No
(Section 25533 of the Califomia Health end Safety Code,with some exceptions,requires registration with the Costa Mesa Fire Department by each business which at any
one time has on hand a quantity of acutely hazardous materials equal to or greater than a weight of 500 pounds, or a volume of 55 gallons, or 200 cubic feet of
compressed gas at standard temperature and pressure).
3 Does or will the applicant or present or future building occupant need to prepare an RMPP(Risk Management and Prevention Program for acutely hazardous materials)?
❑yes 0 N
(Section 25534 of the Califomia Health and Safety Code provides that the Costa Mesa Fire Department may require the preparation,certification and fang with the Fire
Department of an RMPP by businesses which are required to register acutely hazardous materials with the Fire Department.
4 If an RMPP is presently required,has Section 25534 of the California Health and Safety Code been fully complied with? 0 Yes 0 No
_._ _urels with torwilloror occupant at any other
for toe wonk which district the subject age c this application ee0Permit for such construction or modification
from the South Coast Air Quality Management District or from other air pollution control or agency? Yes u No
(Section 65850.2 of the Califomia Government Code requires that the requested information be furnished on applications for non-residential building permits).
6 Will any part of the facility to be constructed under this permit be within 1000 feet from the outer boundaries of a school? ❑Yes ❑No
(If"yes',the fadiity must meet the requirement of Sections 25534 and 42303 of the Califomia Health and Safety Cade)_
7 If a permit from the South Coast Air Quality Management District or other air pollution control district or agency is required for the work which is the subject of this
application,have all of the disclosures prescribed by Califomia Health and Safety Code Section 42303 been made? ❑yes 0 No
8 (If"yes",attach certificate of compliance from the appropriate air pollution control officer).
CERTIFICATE OF COMPLIANCE:I certify that under penalty of perjury the information given above is correct.I agree to comply with all state laws and city ordinances
regarding Hazardous Materials and Emissions.
Signature: Date:
CERTIFICATE OF COMPLIANCE AND AUTHORIZATION OF ENTRY: I certify under penalty of perjury that I have read this application and state that the information given is
correct. I agree to comply with all state laws and city ordinances relating to building construction,and authorize representatives of the City of Costa Mesa to enter upon the
above-de d property for inspection purposes.I agree not to occupy or allow occupancy of any building authorized by this permit until final inspection.
./ CH44� _.....--
r -d f
Ignature Of Legal Owner(s) Dat
And/Or Authorized Applicant Date
CODE t INSPECTION TYPE all MBA COOP( INSPECTION TYPE MI allal&A
1616 Fixed System Final Fire Prevention 206 Final Mechanical
1266 Pool Spa Final 208 Final Plumbing
' 200 Final Re-Roof 210 Final Electrical
201 Final Block/Retaining Wall 212 Final Fire Prevention
202 Final Factory Fire Place 220 Final Planning Approval
203 Final Sign 222 Final Site
204 Final Demolition 250 Final Building/Occupancy ,/OW01 11�
•
45. Dimension on thiplans 30" min. cl idth for water closet compartment anti ai. clearance in front of th'�
closet. (UBC 2904)
46. Wall coverings in showers or tubs with showers shall be cement plaster, tile or approved equal to 70" above drain. (1
807.1.3)
47. Net area of shower receptor shall be not less than 1,024 sq. in. of floor area, and encompass a 30"min. diameter circle.
(UPC 410.4)
48. Provide one openable escape window or door meeting all of the following: an openable area of not less than 5.7 sq. ft.,
24" min. high and 20" min. wide, and a sill height 44" max. above the floor in 4e4fieri'in5 . (UBC 310.4)
49. Show location(s)of hard-wired smoke detectors: (UBC 310.9.1)
a. Centrally located in corridors (or areas) leading to sleeping areas, and inside each sleeping room.
b. On ceiling of upper level in close proximity to the stairway when sleeping areas are on an upper level.
c. On each floor level and in basement.
d. In the adjacent room (or area) where the ceiling height exceeds that of the hallway by 24"or more.
e. Battery operated smoke detector permitted in existing construction.
f. Note on plan: detector shall sound an alarm audible in all sleeping areas.
g. Smoke detectors shall be hard-wired and equipped with battery backup.
EXITS. STAIRS AND RAILINGS
50. One exit door shall be not less than 3'-0"wide and 6'-8" high and provide 32" min. clear width. (UBC 1003.3.1.3)
51. Landings at doors shall have a length measured in direction of travel of not less than 36". (UBC 1003.3.1.7)
52. Within individual units a door may swing over landing that is not more than 1" below the threshold or 8" max. if the door
does not swing over the landing. (UBC 1003.3.1.6)
53. Occupants on floors above the second story shall have access to two separate exits. (UBC 1004.2.3.2) (EXCEPTION:
occupied roof area or third floor within an individual dwelling unit less than 500 sq. ft. may have one exit.)
54. Provide section and details of interior/exterior stairway showing:
a. 8" max. rise and 9"min. run; or, 7" and 11", respectively, where stair serves two units (UBC 1003.3.3.3)
b. 36"min. width (UBC 1003.3.3.2)
c. 6'-8" min. head room (UBC 1003.3.3.4)
d. Details and notes showing framing (stringer) sizes, bracing, connections and footings
e. One-hour fire-resistive construction on enclosed usable space under the stair (UBC 1003.3.3.9)
55. For winding stairs provide 6" min. tread and provide the required run at a point 12"from the narrow side of the tread.
(UBC 1003.3.3.8.2)
56. Spiral stairway shall not serve as required exit for area exceeding 400 sq. ft. (UBC 1003.3.3.8.3)
57. Provide manufacturer, model # and ICBO # for prefabricated spiral stair. Alternately, submit construction drawings and
structural calculations for spiral stair and supporting elements.
58. Provide spiral stairway column base connection/footing detail.
59. Provide connection details on plans for guardrails and/or handrails on open sides of balconies, decks, landings, and stairs
adequate to support 20 pounds per lineal foot load applied at a right angle to the top rail. (UBC Table 16-B)
60. Handrails shall satisfy the following: (UBC 1003.3.3.6 and 509)
a. Provide continuous handrail for stairways with 4 or more risers (2 or more risers where stair serves two units)
b. Handrail shall be 34"-38" above the nosing of the treads
c. Openings in balusters shall be less than 4" in diameter at open side(s)
d. The handgrip portion of the handrail shall be 1-1/4"-2" in cross-sectional dimension with 1-1/2"clearance to wall
61. Provide 36" min. high guardrail for decks, porches, balconies and raised floors (more than 30" above grade or floor below)
and open side(s) of stair landings. Openings between balusters/rails shall be less than 4" in diameter. (UBC 509)
GARAGE AND CARPORT
2552-46 4
1997 UBC HANDBOOK
20 IN.
le—CLEAR-1 •
341/8 IN.
CLEAR
/ T\ /
411N. �N j
CLEAR
OAREAABLN
7 50.FT. \ 24 IN. N/ OPENABLE
CLEAR /N AREA=5.7 SO. FT.
/ \\
✓ N
MINIMUM SIZE MINIMUM SIZE
WINDOW FOR 20 IN. WINDOW FOR 24 IN.
CLEAR WIDTH 44 IN. MAX. CLEAR HEIGHT
sz FLOOR
For SI: I foot=304.8 mm. I square foot=0.093 m2.
EMERGENCY ESCAPE AND RESCUE WINDOW
FIGURE 310-1
The requirement for emergency escape and egress openings Window wells in front of emergency escape windows also
in sleeping rooms is because a fire will usually have spread be- have minimum size and escape requirements. These require-
fore the occupants are aware of the problem, and the normal exit ments were added to address those emergency escape windows
channels will most likely he blocked. The dimensions pre- that occur below grade. Obviously,just providing the standard
scribed in the code, and as illustrated in Figure 310-I for exterior emergency escape window criteria to these windows will get
wall openings used for emergency egress and rescue,are based occupants through the window but the window well may actu-
on extensive testing by the San Diego Building and Fire Depart- ally trap them against the building without providing for their
ments to determine the proper relationships of height and width escape from the window well or providing for firefighter
of window opening to adequately serve for both rescue and es- ingress.
cape.The minimum of 20 inches (508 mm).for the width was
The minimum size requirements in cross section are similar in
based on two criteria: the width necessary to place a ladder with- intent to the emergency escape window criteria: that is, to pro-
in the window opening and,secondly,the width necessary to ad- vide a nominal size to allow for the escape of occupants or •
mit a firefighter with full rescue equipment. The minimum ingress of firefighters. The ladder or stair requirement is the
24-inch(610 mm)height dimension was based on the minimum main difference.
necessary to admit a firefighter with full rescue equipment.
Emergency escape windows below the fourth story are not
It is the intent of the code that the windows required for emer- required to have an escape route down to grade:however,those
gency escape or rescue be located on the exterior of the building windows below adjacent grade are so required. When the depth
so that rescue can be effected from the exterior or, alternatively, of a window well exceeds 44 inches(I 118 mm), a ladder or stair
so that the occupants may escape from that window to the exteri- from that window well is required.The type of ladder or stair is
or of the building without having to travel through the building not identified in these provisions.However, a permanently fixed
itself. If these windows open into an interior exit court,the exit ladder as required by the Uniform Mechanical Code for access
court must have an exit passageway, that provides access to the to rooftop equipment would be acceptable or any type of usable
public way. stair would suffice.
Remember,these ladders or stairs are provided for emergency
As stated in the code, these windows used for emergency es-
cape or rescue must be operable windows.The intent is that they use and need not fully comply with the code.
be of the usual double-hung,horizontal sliding or casement win- The ever-increasing concern for security, particularly in resi-
dows operated by the turn of a crank. The building official dential buildings,has created a fairly large demand for security
should evaluate special types of windows other than those just devices such as grilles, bars and steel shutters. Unless properly
described based on the difficulty of operating or removing the designed and constructed, these security devices over bedroom
windows. If no more effort is required than that required for the windows can completely defeat the purpose of the emergency
three types of windows just enumerated,they could be approved escape and rescue window. Therefore, the UBC makes provi-
as meeting the intent of the code as long as no tools, special sions for security devices, provided the release mechanism has
knowledge or effort are required. been approved and is operable from the inside without the use of
39
OWNER MATRANGA, GEO. F. DATE 6-18-56
JOB ADDRESS 2351 ,Westminster BUILDING PERM IT NO. 3218
GENERAL CONTRACTOR Dike and Colegrove VALUE $ 8,858.00
t 46 BLOCK TRACT 2• • • R_
GROUP I & J TYPE V ZONE R]1 FIRE DISTRICT 3217
PERMITS ISSUED
INSPECTIONS DATE SUBCONTRACTOR
�[,�C- DATE NUMBER
Footing Trench `�C�/g 7-3`S (
Foundation Forms and Grade to Garage
Rough Framing V' {r 4
Plumbing,Rough to Slab ,,Oft 77 a'
7L. '
Plumbing, Rough Complete V ! .4^ ll- .5 R, ,,4� , D.- S S G 7 "iTemporary Pole v �j
Wiring, Rough •/r�� .7), Ara c
Heating,Rough a •%I�..
Heating,Final A 'A. 4 A r f L. i , .S 41 ( r t/. l • : 4 O .7, O —
Sewep<Ho su e Hewer,St. A r,. ��/,-,,_ 7.-_7
/ C - -
�,t /-J7-t l
Septic Tank or C spool ,id'I� �'j141. „ /� 27 _ _ C ....
Lair" 'no, In Out f a . ��..�r ��_
P. ering G �_ y 3
Plumbing,Final,Fixtures Comple ,,J C
Plumbing, Final Gas Test ���� G ' ~, - .' S
Wiring,Final An /0.3-
Occupancy i r '4%,41
FOPM 210 3M 10.55
.r Costa Mesa Building Department APPLICATION FOR PERMIT
P. O. Box 3!7 BUILDING
• COSTA MESA, CALIFORNIA 1324`7
FOR OFFICE USE ONLY
FOR APPLICANT TO FILL IN Receipt No. I Permit No.
Building
Address 2351 Westminster ,302//P
Costa Mesa, California
Zed d by Date Reo''d. /Date Issued
Nearest j.C> 6 - /Ala
G
Cross sc. Wilson Building
Address
Owner George F. Matranga
Mall Costa Mesa, California
Address 419 E. 17th St Nearest
Tel. Cross S . `/'
City Costa Mesa No. Li 8-1159 Zone / I No.of I Type V Group2,�
Architect or Lie. 7 Plans _/-dn'
Engineer Carlrnn R. MI arilnhrnr#o. Approved
by Date
Address Garden Grove
City tio. CORRECTIONS
contractor Dike and ColegroveN0, 2707
Address 419 E. 17th St
LegalLot I
Description I No. 46 I Block I Tract2959
(Attach Metes and Bounds)
-, •---,
Size of Lot 72 x 105 I No.Now of onBldgLots
none i J i! 'V'\ I ; it -„
0
Vse ofNo.of 1 No.of 2
1 �- i - A
Existing Bldg. none I Families I Rooms-I2 1. /-- ""- . ,
Setback Line from Rear Yard lot
Center of Street 50 t Side Yard 12l .1111'1 :c D
j
DESCRIPTION OF WORK 11 T r
New I X I Alteration I I Addition I ferry „,_. n
Cc
t uoici hen-s4
Repair I I Moving I I Demolish I -
Building No.of
Size 998 SQ ft Rooms 5+ Stories 1
Exterior WallRoof —
Covering Stucco I Covering Comp APPROVALS
Use of New
Building Single family res and gar Foundation Location Inspector • Date
Forms,Materials,
Under-Pinning
Plan X63B Frame: Fire Stops,
Bracing,Bolts
I hereby acknowledge that I have read this Application
and state that the above is correct and agree to comply Lath. Int.
with all City Ordinances and State Laws regulating
building construction. Lath. Ext.
Signature of Dike and Colegrove
Permittee //1{ —y Plaster, Int
Authorized Agt. a ,ti . - c cj e Plaster, Ext.
Valuation nt
iFee $ . a — Masonry Reinforced
$ I 8 /�fiCheck $ // — Bond Beam
J O $ 333 FINAL
FORM 204 10.55 D.P.!S.
.r• -
v
u
c u
Km'
•-
•
:C
n'
•
Street
PLOT PLAN
Show location and distances from
property line and between buildings.
•J
5