Loading...
HomeMy WebLinkAboutPH-1 - 26-205 - 6. Plans - 5/5/202612'-3" 11 ' BEDROOM#4 BEDROOM#5 BEDROOM#3 BEDROOM#2BEDROOM#1 KITCHEN LIVING ROOM DINING PROPERTY LINE = 67' PR O P E R T Y L I N E = 1 0 3 ' GARAGE 7' GATE 7' ' B L O C K W A L L F E N C E PCC CITY SIDEWALK EASEMENT BAKER ST A0 ='1'40' 1 VICINITY MAP PROJECT DATA PLAN SHEETS ATTACHMENT 6 -1- 12'-3" 11 ' BEDROOM#4 BEDROOM#5 BEDROOM#3 BEDROOM#2BEDROOM#1 KITCHEN LIVING ROOM DINING PROPERTY LINE = 67' PR O P E R T Y L I N E = 1 0 3 ' GARAGE 7' GATE 7' ' B L O C K W A L L F E N C E PCC CITY SIDEWALK EASEMENT A1 24" 30 " 15 " 15 " TYPICAL TOILET MINIMUM CLEARANCE REQUIREMENTS CLEARANCE FOR WATER CLOSETS TO BE A MINIMUM OF 24" IN FRONT ND 15" FROM CENTER TO ANY SIDE WALL OR OBSTRUCTION. ='1'40' -2- 7' - 1 0 " 15 ' - 2 " 12 ' - 8 " REAR ELEVATION A2 NORTH ELEVATION SOUTH ELEVATION -3- STUCCO ROOF GLASSALUMINUM WOODEN DOORGLASS ALUMINUM STUCCO ROOF A3 EAST ELEVATION WEST ELEVATION -4- BA K E R S T R E E T PROPERTY LINE FENCESOLAR PROPERTY LINE BOUNDARY WALL DRIVEWAY 105'-8" 67 ' - 5 " 105'-9" EX I S T I N G D W E L L I N G SITE PLAN Scale 1/8" = 1'-0" ROOF PLANS GENERAL NOTES 1. INSULATION HAS 1" MIN. AIR SPACE ABOVE IN VAULTED CEILING. 2. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. 3. COMPOSITION SHINGLE ROOF OVER LAPPED 30# A.S. FELT (TYP. THRU OUT) 4. COORDINATE INSTALLATION OF NEW ROOFING WITH OTHER TRADES. REPORT ANY CONFLICTS WITH ITEMS INSTALLED BY OTHER TRADES TO DESIGNER. 5. ALL ROOF CURBS FOR NEW ROOFTOP EXHAUST FANS , HVAC UNITS AND CONDENSING UNITS SHALL HAVE CURB HEIGHTS THAT WILL ALLOW FOR A MINIMUM OF 8" BASE FLASHING HEIGHTS FOR THE ROOF SYSTEM. 6. ALL PLUMBING VENTS SHALL EXTEND ABOVE THE FINISHED SURFACE OF THE ROOF SYSTEM AS REQUIRED TO PROVIDE FOR A MINIMUM OF 8" BASE FLASHING. 7. PROVIDE 36" WIDE WALK PADS @ SERVICE SIDE OF ALL MECH. EQUIPMENT. 8. ALL EXPOSED METAL FLASHING/ TRIM PIECES TO BE PRE-FINISHED 24 GA. STL. U.N.O.. PROVIDE PRE-FINISHED OR FIELD PAINT FLASHING ONLY AS NOTED. 9. R903.4.1 OVERFLOW DRAINS AND SCUPPERS. WHERE ROOF DRAINS ARE REQUIRED, OVERFLOW DRAINS HAVING THE SAME SIZE AS THE ROOF DRAINS SHALL BE INSTALLED WITH THE INLET FLOW LINE LOCATED 2 INCHES (51 MM) ABOVE THE LOW POINT OF THE ROOF, OR OVERFLOW SCUPPERS HAVING THREE TIMES THE SIZE OF THE ROOF DRAINS AND HAVING A MINIMUM OPENING HEIGHT OF 4 INCHES (102 MM) SHALL BE INSTALLED IN THE ADJACENT PARAPET WALLS WITH THE INLET FLOW LOCATED 2 INCHES (51 MM) ABOVE THE LOW POINT OF THE ROOF SERVED. THE INSTALLATION AND SIZING OF OVERFLOW DRAINS, LEADERS AND CONDUCTORS SHALL COMPLY WITH THE CALIFORNIA PLUMBING CODE. 10. PROVIDE ICE BREAKS AT ALL PERIMETER AREAS OF STANDING SEAM ROOFING. 11. PROVIDE 36" WIDE WALK PADS @ SERVICE SIDE OF ALL MECH. EQUIPMENT. & PROVIDE 36" WIDE WALK PADS AROUND ALL ROOF HATCHES & 72"X72" PADS AT LADDERS. 12. ALL EXPOSED METAL FLASHING/ TRIM PIECES TO BE PRE-FINISHED 24 GA. STL. U.N.O.. PROVIDE PRE-FINISHED OR FIELD PAINT FLASHING ONLY AS NOTED. 13. GUTTERS - ALL GUTTERS TO BE PRE-FINISHED 24 GA. STL. . PROVIDE PRE-FINISHED GALV. STL. BENT PLATE BRACKETS AND 14GAX1" GALV. STL. SPACERS @ 36" O.C. MAX. - STAGGER W/ EACH OTHER @ 18" O.C.. PROVIDE PRE-FORMED 14. GUTTER E.J.'S PER SMACNA FIG. 1-7, TYP. @ 30'-0" MAX.. PROVIDE S.S. SCREENS @ ALL GUTTERS PER SMACNA FIG 1-24. 15. ALL DOWNSPOUTS TO BE PRE-FINISHED 24 GA. GALV. STL., PER SMACNA FIG 1-32B. DOWNSPOUTS ARE 6"X6" U.N.O., LOCATED AS NOTED ON ROOF PLAN. 15GA.X2" GALV. STL. HANGERS @ 48" O.C. MAX. PER SMACNA FIG 1-35B. 16. PROVIDE PAINTED 4' TALL CAST ALUM. DOWNSPOUT BOOTS @ ALL DOWN SPOUTS, TIE INTO SUB-GRADE DRAINAGE, RE: CIVIL. 17. TAPERED INSULATION TO BE 1/4" PER FOOT MIN. SLOPE TO DRAIN. ROOF PLAN SHOWS TAPERED INSULATION FOR GRAPHIC REPRESENTATION ONLY. CONTRACTOR TO VERIFY INSULATION REQUIRED TO SLOPE PRIOR TO MEMBRANE INSULATION. 18. PROVIDE TAPERED INSULATION CRICKETS 1/4" PER FOOT MIN. SLOPE @ HIGH SIDE OF ALL MECHANICAL UNITS AND ROOF HATCHES, TO SHED WATER AROUND AND MAINTAIN POSITIVE ROOF DRAINAGE. 19. ALL WOOD BLOCKING AT ROOF EDGES, RIDGES, ETC. TO BE 2X FR-WD BLOCKING. 20. VERIFY ELEVATION OF ROOF DRAIN RELATIVE TO OVERFLOW SCUPPER PRIOR TO INSTALLATION OF SCUPPERS A4 1/2" CDX PLY APROVED ROOF COVERING ALTERNATE LOCATION OF GWB OR 2X BLOCKING IF NO CEILING FINISH IS 2X4 BLOCK FASCIA PROVIDED SOFFITBOARD 5/8 TYPE XGYPSUM SHEATING STUCCO FINISH 5/8 TYPE XGYPSUM WALLBOARD 2X FRAMING STRUCTURALSHEATING ASREQUIRED 1 HOUR RATED WALL AND4 SCALE: NTSPROTECTED EAVE OVERHANG NOTES: 4" MIN. - THE ROOF OVERHANG CANNOT EXCEED 12" AND MUST BE ONE-HOUR PROTECTED OR EQUAL ON UNDERSIDE IF ADU IS LOCATED UNDER 5' FROM PROPERTY LINE OVERHANG SHALL BE ADJUSTED TO MIN. REQUIRED. AS PER CODE SECTION R302 12" OR -5- 8' - 0 " A-A (NTS) A5 5 1 HOUR FIRE - GENERIC SCALE: NTSEXTERIOR WALLS GYPSUM WALLBOARD, GYPSUM SHEATHING, WOOD STUDS EXTERIOR SIDE: ONE LAYER 48" WIDE 5/8" TYPE X GYPSUMSHEATHING APPLIED PARALLEL TO 2X4 WOOD STUDS 24" O.C. WITH 1-3/4" GALVANIZED ROOFING NAILS 4" O.C. AT VERTICALJOINTS AND 7" O.C. AT INTERMEDIATE STUDS AND TOP AND BOTTOM PLATES. JOINTS OF GYPSUM SHEATHING MAY BE LEFT UNTREATED. EXTERIOR CLADDING TO BE ATTACHED THROUGH SHEATHING TO STUDS. INTERIOR SIDE: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD,WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENNER BASE APPLIED PARALLEL OR AT RIGHT ANGLES TOSTUDS WITH 6d COATED NAILS, 1-7/8" LONG, 0.0915" SHANK, 1/4"HEADS, 7" O.C. (LOAD-BEARING) THICKNESS: VARIESAPPROX. WEIGHT: 7 PSFFIRE TEST: SEE WP 3510(UL R3501-47,-48,9-17-65 UL DESIGN U309,UL R1319-129, 7-22-70,UL DESIGN U314) EXTERIOR SIDE INTERIOR SIDE SECTION A-A -6-