Loading...
HomeMy WebLinkAbout2330 VANGUARD WAY - Building Permits (31) Applicant to fill in all spaces except those within heavy border lines and sign all appropriate declarations. • CITY OF COSTA MESA PE MIT NO. TRACT NO. LOT NO. BLDG.NO. E I: /.".,./- CONSTRUCTION PERMIT —/p,XB'S 11481 I �j I03 I i�l r Applicant's Mailing Address P-n- BOX 10841 r SPY_Hi11 S 90713 TYPE OF CONSTRUCTION ® NEW U ADD U ALTERATION U REPAIR Project Address 7 30 vanguard Way B-103 ❑ CONVERSION 0 DEMOLISH 0 OTHER • Owner's Name 1't Tannin T.td _Phone DESCRIPTION OF WORK Nf''1i (J. CO lIIil r ZONING REGULATIONSp Address P.O PDX 10R41, 13F`A_ Hi 11S, C'�1 90211 TYPE OF PERMIT ® GRADING LA FOUNDATION STRUCTURAL A.P,# i- jq- C)Oj ty� ZONE NUJ Arch/Eng. Clark 6 Hedrick, Tnr License Nb. ( -257R 0 TENANT 0 ELECTRICAL 0 PLUMBING 0 MECHANICAL PLNG. REF.,4,: -(13-IID BUILDING •• T-I)I+81 • )0-T / ^1/h iI GKTRAry r/1 es- �s1 J Address 11969 San Vicente B1.42.5 L.A. 004• ❑OTHER • PTO ROPERTY LINE car c) Ui(,f� REAR YARD (TO P/L) 3zj 1fl bl((r] Contractor's Name Phone PROJECT DESCRIPTION SQ,FT. 1 525 OCCUPANCY R-1 ^ J Address(mailing) n CONSTRUCTION TYPE V - 1 hr. VALUATION 80.000 LEFT SIDE YARD [ RIGHT SIDE YARD aist ZONE R-9 GRADING CU.YDS. Site ACRFe PKG.SPACE REQ. o/ 5 PROVIDED 2 5 License No, __ O( LICENSED CONTRACTOR DECLARATION Remarks: �li(�.1T1 B - Unit- 103 (, STREET WIDTH Q7�/ PARK FEE$ 1 , 5 / I hereby affirm that I am licensed under provisions of Charter 9(commencing Q7 �C L1J ��y,� y.,�/� with section 7000) of Division 3 of the Business and Professions Code,and SPECIAL CONDITIONSROLD FOR SPECIAL REOUIRFMFNTQ• (1 )+1.11 (1f I it y/ my license is In full force and effect. ..��It..,,., rut jj..,,,,,, ,,.,,�y. {-x ,,,{.•_ �,pi License Class License No. PLUMBING v,.,l l l 11 1 u `UL.1 atria-11d ti I ,tit , (r re(writ)tie e Date Signature Bar Sink Sewer CapELECTRICAL _b WORKERS'COMPENSATION DECLARATION / - - //. as arab affirm that I have a certificate of consent to self-Insure or a certificate Automatic Washer Meter Clover 100 amps Workers' Compensation insurance, or a certified COPY thereof (Section Backflow Preventer / Sewer Connection .800, Lab. C.) Backflow Irrigation Solar CollectorsConstruction Pole Sub Panel Policy No. Company Cooking Unit Sub Pole 8 Certified copy is hereby furnished. Bathtubs Solar Piping Certified copy Is filed with the city Building Division, / Dishwasher / MotorsX10-1 HP ❑114-8 ll Date Applicant Clarifiers Solar Tank EXEMPTION FROM WORKERS'COMPENSATION DECLARATION / Dryers XIGas ❑ElectricInc.Solar 09-15 HP 016-15+ This section need not be completed if the ($100)or Dishwasher Swimming Pool w/Spa ( ppermit is for one hundred 9 P less). "3 Fan •Microwave I certify that In the performance of the work for which this permit is Issued 1 Drinking Fountains Urinal shall not employ any person In any manner so as to become subject to the / F.A.U. 'l Pole Light S Workers' Compensation Laws of California. Floor Drains Water Close[ ?� Date Signature �1 / NOTICE:1/,after making this declaration,you should become subject to the Floor Sinks Water Heater p�.f Ixtures Range Workers' Compensation provisions of the Labor Code, you must forthwith - r comply with such provisions or this permit shall be deemed revoked. Gas Service / Outlets sr w[.:.. - . Device Boxes Sign CONSTRUCTION LENDING AGENCY I hereby affirm that there Is a construction lending agency for the performance Utle[s Interceptors /• 1 3 Standing Sections of the work for which Nis permit Is issued (Section 3087 Civ. C.) - �+•,—;� a• Switches Lender's Name / Kitchen Sink { ) _ Trash Compactor Lender's Address Lavatories [� z ; Garbage Disposal OWNER BUILDER DECLARATION 1 7 I hereby affirm that I am exempt from the Contractor's License Law for the Generator 00.5 KW 05-15 KW following reason (Section 7031.5 Business and Professional Code: Any city or P-Trap • ^ �� ' county which requires a permit to construct,alter Improve,demolish or repair /r y Transformer ❑15-50 KW • any structure, prior to its'Issuance, also requires the applicant for such permit ' Roof Drains r'I^ _—� to filo a signed statement that he/she Is licensed pursuant to the provisions of the Contractor's License Law'(Chapter 9(commencing with Section 7000)of rp "- ❑5U+KW Reinspection Fee • $15 J:Ppjsion 3 of the Business and Professions Code) Or that he/she is exempt Showers D P. 1 ion Fee $15 3i;,,,_M1M1,�S''efrom and the basis for the alleged exemption, Any violation of Section / Meter Aup to 100 amps Issue Fee 'S 3 y: i.5 by any applicant for a permit subjects the applicant to a civil Ifialty of not more than five hundred dollars($500). Service Sink Issue Fee $ 3 Zoning Approved By �r+ I AO Date 10 (� I, as-owner of the'property or my employees with wages as their sole ' < compensation will do the work,and the structure Is not intended or offered - • MECHANICAL Application Approved By U2fl( f A•3-1-1# nate /A s©'83 for sale (Section 7044, Business,and Professional Code: The Contractor's -- - - --- - - - -- --- - - -- --- - - l/ License Law does not apply to an owner of a property who builds or improves Boiler Refrigeration System thereon, and .who does such work himself/herself Or through his or her own Application Issued By Date employees, provided that such Improvements are not intended or offered for ❑0.100,000 BTU ❑100,000 BTU sale. If, however, the building or improvement is sold within one year of corn- Duct-Under Ground SUMMARY OF FEES • PI ion,the owner will have the burden of proving he/she did not build or Im- .ppvefor the purpose of sale). Duct-Structural System Repair/Alteration BUILDING PERMIT $ t71..°0. SMTP $ 5:60 1,as owner of the property,am exclusively contracting with licensed con •- tra ors to construct the project (Section 7044,Business and Professions Code: 3 Duct-Ventilating PLAN CHECK $ PERMIT The Contractor's License Law does not apply to an owner of property who builds or improves thereon,and who contracts for such projects with a con- Exhaust System 0 Multiple 0 PLUMBING $ ISSUANCE $ tractor(s)license pursuant to the Contractor's License Law). •. GRADING $ ❑ I am exempt��l� ////����� under Section B.3 P.C. •r this reason / Firepl/Fact[.B1t.ICBG 4k PLAN CHECK $ Date / ilXS ,tJPsA / He in System& DuctingELECTRICAL $• $ E Owner ��pl /. g y PLAN CHECK $ MICROFILM • $ I hereby ertify that I have read this appli<atlon and state t at the above 0-100,000 BTU ❑100,000 BTL • information Is correct. 1 agree to comply with all city and cots ty ordinances /\ TOTAL FEE ' $ and state laws re ting to building construction, and hereby authorize repro- MECHANICAL $ sentatives of t city to enr pit th rd above- entioned prop. ty for Hood Or Type! LESS . Inspection ur y _ _ _ - / Canopy Type II 0 Reinspection Fee $15 PLAN CHECK $ ADVANCED PC $ Signature 9 - _ Date / _Se Drivers' L cense or SS# - . /, Registers �: U) Issue Fee $ 3 . FINAL FEE $ S 78'6° _ CMF 0865-46 rev,12/82 White-Building;Canary-Applicant;Pink-Accounting;Goldenrod-Assessor ‘--Ii CONSTRUCTION AND PLANNING -. ea �. " .. ,- - , ' ,POOL 'A -- . - - - - .APPROVALS .`, Permit#- -' •` Date 'inspector -. :APPROVALS Permit# - Date Inspector - 1. Temporary Electrical Service or Pole - • aj -^ 52'Pool &Equipment Location r 2' Soil Pipe-Undrgrnd:. ' C: . - . " `•; J. :: ' . 53:- Steel Reinforcement • _ • , _ 3' Electrical Conduit Utility-Uhdrgrnd) - - 54:.'Forms' " - ' 4. Electrical Conduit-Undrgrnd. : ' _ '' 1 55. Electrical Bonding - 5: Steel Reinforcement ' n ` ` 56., Rough Plumbing& Pressure Test 6: Electrical LIFER Grnd. 57. APPROVAL TO COVER-GUNITE 7. Footings - -• - , ' l, " - 58. Electrical Conduit-Undrarnd.: 8. Foundation - ` - 59. Gas Pipe, 0 Undrgrnd.,Test 9. Water Pipe-Undrgrnd. - _ 60. Backwash.Lines,P-Trap, 0 Undrgrnd. 10. Structural Floor System ' ' 61. APPROVAL TO DECK 11. Property'Sewer Line & House Connection + - 62. Backwash & Receptor-Final 12. Sewer Cap , ' - - , , ;-63. Heater & Vent-Final 13. Roof Drains - _ : . 64. Plumbing System - Final - , 14. Rough Plumbing -•- - - ' 65. Electrical-Final - - '15:-Rough-Electrical-Conduit j_ , - - - -;66.,•Solai'System-Final - , "• '16. Rough-Eleciric Wiring. „ I ' ; - + -. I- -r " I - - - ' 67. Fencing& Access Approval ,'17. Rough Wiring Sigh; ' ' 1 - - 68. APPROVED FOR PLASTERING 18. 'Rough"Electrical-T,Bar Ceiling' , - - ' 69. POOL/SPA SYSTEMS FINAL ' I, 19. 'RoughhHeating&Air Conditioningr • 1 ' I - FIRE DEPT. REQUIREMENT- ' 20. Rough-Factory Fireplace, ' ' j APPROVALS'' t. Permi # ' 21. Duds,in Structure ° - _. � � 70.j�Unde�ground Hydros , ,i22. 'Ducts, Ventilating ' '• '' r • ' , 71. Product'Pipi' ng OGels ❑Oil • 23. Gas Pipe-Rough& Test i �_,' ; , ' 72 Underground Flush' , 1 24. Roof Framing 73i� Undergrnd.Storage•Tank 0 Gas 0 Oil 25. Roof Sheathing , _ , ' 74. Overhead Hydro , r -26. T-Bar Ceiling (Structural) & Monocoat 75. Dry Chemical f _ •27. Frame and Flashing , 1 : I, I 76:; Dry Standpipe .i i , • 28. „Lathing& Siding :, -, , li I t/?J FIXED SYSTEM FINAL " , .Insulation - ` a - ' t 29. p*76. EIRE PREV. FINAL "30.'Drywall Nailing 6 ttJo1es:: I i 31. ''Plaster Brown Coat - ' , • I I ' 1' I ' • 32. 'Electrical Power Meter-Final : I i 1 Th"--------......0 33. IFinal Ele&ric ._ , ; • I _ • _ 34. Final Heating & Air Conditioning • . • 35. Final Gas Pipe-Test _ 1 . - I • 36. Hood or Canopy I n. - 37. Final Factory Fireplace- ' _ i' - - 38. Final Plumbing - - ' , 39. Water Service-Final, I 40. Gas Service-Final I - . 41. Solar Domestic-Final 1 , „ - - , - _ - " . 42. Backflow Preventer ,' I :-• -- -- r r - - - 43. Backflow Irrigation t ! i • - {` 44. Landscape Irrigation Sy3tem . " - •. - . P . 45. Sound; Attenuation >, ,^ - ' 46. Handicap Regulation"s ) •, '- I , ' - ! , 47. FINAL STRUCTURE & BUILDING - , , ' • 48. Special Regdirements Completed ' 1 49. Electrip Release to Edison I 50. Gas Release to Southern California Gds Co ' 1 51. CERTIFICATEOF OCCUPANCY ' ' I ' No tt 1 Date - - • City of Costa Mesa Development Services Department CERTIFICATE OF OCCUPANCY No. 001651 Building Safety Division P.O.Box 1200 Costa Mesa,California The Building located at 2380_Varwnnni Way R-103 has been inspected and found to comply with the provisions of all City of Costa Mesa Ordinances applicable thereto fora Group R-1 Occupancy. Use of Building Condominium Legal Description 419-151-06 (See reverse side for Metes and Bounds) Building Permit No G16R34 Electrical Permit No. G16834 Plumbing Permit No. G16834 Mechanical l rmit No. G16834 Number of apartments / and/or guestrooms ISSUED TO: Building Official J/- ti- / �� -1 Newport Ian4inc4 Limited 71/4„/,P O Box 10843 by. �' Beverly Hills, CA 90213 Date //9/b?‘ This This Certificate of Occupancy SHALL BE posted in a conspicuous place on the premises and SHALL NOT BE removed except by the Building Official of the City of Costa Mesa under Sec. 307 lel U.B.C. CMF 1015-46 rev.1/83 White•Owner;Canary-Numerical File;Pink-Bldg.Permit File • • Applicant to fill in all:Daces except those within heavy border lines and sign all appropriate declarations. 5679 I I 6/3 , 7-up 1 ; I • CITY OF COSTA MESA - N PERMIT NO. TRACT NO. LOT O. BLDG.NO. CONSTRUCTION PERMIT (� t L463L[ 1/YR) / ,B—/03 • Project Address • : L C ,• : B �. - . TYPE OF CONSTRUCTION [l g NEW El ADD U ALTERATION U REPAIR Applicant's Mailing Address • 0 •to•. 0• e - ❑ CONVERSION ❑ DEMOy,S H ❑ OTHE A.P.*, a Zone ' t�'"F �/q - /5) R- Owners Name t - WI rt -A s 0 1.. IR Phone -- -•' - O S Main Building: Accessory Building: Z Address QQ- PfJ( IO84Vt. I3EurLv wus.eAi. gnat•, TYPE OF PERMITQ•7 UGRAPING Iy7 FOUNDATION 1STRUCTURAL T FfOnt�� y�ne�r� / N Arch/Eng. C LARK- NEDRICK License No. C-SR49 0 TENANT yv ELECTRICAL KJ` PLUMBING yJ MECHANICAL B / ^ �` 5� 5� N 11969 SAM VICEIytF PfL. I—ft ❑OTHER A Rear Address ��II qq�� C Right • G Contractor's Name PAUL TETRICK PhAfiO3/R O-67a 1 PROJECT DESCRIPTION SQ. FT, ISSN OCCUPANCpY A77�T-R� -e #, R I Address(mailing) II RSR !.A GRA1NGE RUE., L.R 900x5 CON ST RUCTION TYPE --r- N VALUATION$ 82, 1 25 $ Left A!/ /9<hc� E ZONE GRADING CU.YDS. ACRES Pin Ref.# 9 /g Park.Fees $ �.g Q 81) City License No. lF 33x7 g 9• �•�- "b l���,3(J U LICENSED CONTRACTOR DECLARATION / - Remarks: C '7fr OQ/ g5/4 Parking Req./Provided _ ^7 e. I --- I•hereby affirm that.I am licensed under provislont of Charter 9 (commencing /� C'L - R M with section 7000) of Division 3 of the Business and Professions Code,and Use of Building: K Lp5 ' Cep4/29- .E my license Is in full force and effect. Ucen Cls S- • / s- j 1 • • • PLUMBING FEES Planning Notes: _ •-.,,..ir>t - M Date I- 'a-:L Signature �n1t �t.%�7�>L�- HOLD FOR SYhCI/�L {tc.y,°`�•"�`'fS - , • E WORKERS'COMPENSATION DECLARATION / / Bar Sink Showers . Z CO N I hereby affirm that I have a certificate of consent to self-Insure or a certificate Backflow Preventer • Service Sink S of 'Workers' Compensation Insurance; or a certified copy thereof (Section - - - - - - • - - -- - - - 3800, Lab. Cl - .Backflow Irrigation Seim'?Cap - - - ELECTRICAL -- . FEES Policy No. .`7 67 138- 84 Company n/X'fE � IR S)DS-1'IUWD ^ _ - ❑ Certified copy is hereby furnished. ••mpany ' 0_Bathtubs / Sewer Connection -. _ Co Automatic Washer Transformer 0 15-50 KW - (,.(0 • Q'p Certified copy filed with the City[ ryy9 pdi • !/!!I/g(/ Clarifiers - ?' - 0 50+KW - /'" Date II-) - Applicant Solar-Collectors • ' Construction Pole Sub. EXEMPTION FROM WORKERS'COMPENSATION DECLARAT Dishwasher - Solar Pipin p (This section need-not be completed If the permit is for one hood 0 (5300) or9�O/l6!/ OyLY • SG�O • Cooking Unit. - A" Meter ,�up to 100 amps JC'� less). i I I certify,that'in the performance of the work for.which this permit is issued I Drinking Fountains Solar Tank /,, Dishwasher,. Meter Cover 100 amps Cd , shall not employ any person in any manner sO at t0 beco to bject to the - - - t ' - I Workers' Compensation Laws of California. '7•' Fioor Drains SwimmingPool w/Spa ' • �j• _ P Dryers AGas ❑Electric Sub Panel Date Signature / • fP NOTICE: If,after making this declaration, you should become subject to the Floor Sinks ' Urinal - Fan - -- • ! I Motors 00.1 HP ❑1 -8 Workers' Compensation provisions of the Labor Code, you must forthwith" - - • - - 01,4- S OD , comply with' such provisions or. this permit shall be deemed revoked. Gas Service • Outlets ' CONSTRUCTION LENDING :AGENCY' - : _ �' Water Closet' 1 F.A:U. t ,Inc.Solar 09-15 HP 016-15+ (f OO I hereby affirm that there is a construction lending agency for the performtee Interceptors i - / Water Heater _L N /5-Fixtures • -Microwave 3^\ of the !work forwryfcp this permit' is Issu@@y (S�cHgn' 30 7 Civ. C. lJ Lender's Name W tYFRV{ps F11,5E J-10RRnAtpE C7. Kitchen Sink Water Service - • Lender's Address 97 1919: LJI�JC01-A) ul LIAG-E .PR f CI11 01 / . _ _ 4 CO +;� Device Boxes Pole Light OWNER BUILDER DECLARATION SAAR 4EMt) C1�, q-5 ? q Lavatories WAIN yit/I, /L- R JO -�j"TZOutlett • • Range • I hereby,affirm-that I am exempt fro a Contractor's License taw or he P-Trap• 'reason (Section.7031.5 Business and Professional Code: Any city or P 2' Switches . Sign S 40 county which requires a permit to construct,alter,Improve,demolish or repair • , . . - / any structure, prior to its Issuance, also requires the applicant for such permit Roof Drains ' Gariage Disposal $tanding,Sections to file a signed statement that.he/she is licensed pursuant to the provisions of — - - -• '� the Contractor's License Law (Chapter 9(commencing with Section 7000)of • ' , -- - !visiom 3'of the Business and Professions Code) or that he/she Is exempt - . ,• - Generator ❑0.5 KW 05-15 KW Trash Compactor erefrom and the basis for-the alleged exemption. Any violation of Section - - --77 "� A 1 �/J • .031.5 by any- applicant for a permit subjects.the applicant to a civil • ReinsI $'3 !/ %'7711 r`- Z oc • penalty of not more than five hundred dollars($500). lection Fee $25 Issue Fee - LJ I„as owner of the property or my employees with wages as their sole Reinspection Fee $25 • Issue Fee ' $ 3 Compensation, will do the work,and the structure Is not Intended or offered MECHANICAL - FEES for sale. (Section 7044, Business and Professional Code:, The Contractor's . -- -- -- -- - - - - - -- -- - --- - PUBLIC SERVICES REQUIREMENTS: License Law does not apply to an ownerofa property who builds or Improves • Boiler . , Hood or Type I 0 • ^Kr ��I ��'ffl;;;��� ��- thereon;and,who does such work himself/herself or through his or her own Zoning Approved By • 1/f C-II Date / employees, provided that such improvements are not intended or offered for Canopy Type 11 0 • , SAC- sale. If, however, the building or Improvement is sold within one year of com- Duct-Under Ground ' • . Application Approved By - Date 8� pletion„the owner will have the burden of proving he/she did not build or-im- • - , M � LJrove for the purpose of sale). Duct-Structural Refrigeration System . • Application Issued By • l Dab. - -g I,'as owner of the property, am exclusively contracting with licensed con- Oa100,000 BTU ❑100,000 BTU ' tractors to construct the project (Section 7044,Business and Professions Code: LL Duct-Ventilating ', ' g SUMMARY OF FEES The Contractor's License-Law does not apply to an owner of property who I - / sl� builds or Improves thereon, and who contracts for such projects with a con- Exhaust System 0 Multiple 0' System Repair/Alteration BUILDING'PERMIT $ L4C0•('X SMIP . $ ' `P tractor(s) license pursuant to the Contractor's License Law). - - PLAN CHECK $ 2-inn :CO PERMIT 0 ram exempt under Section - B.& P.C.for this reason 1 Firepl/Fact.;BIt. ICBG# 1.50 l' "I ' PLUMBING $ •2, • • • Date Owner - Heating System& Ducting PLAN CHECK • ' $ 8.1C ENERGY P.C. $ - ' I hereby certify that I have read this applicatibn and state that the above ' I. iNO-100,000 BTU 0100,00067E y 00 ELECTRICAL $ -�O GRADING $ information Is correct. I agree to comply with all city and county ordinances - - and state laws rales ng to building construction,and hereby authorize repro- PLAN CHECK IQ.vo MICROFILM $ ' sentatives of• hi Ity to liter u on the above-mentioned `property for $ inspection pu s- //�� MECHANICAL $ - rIq-� 1°14• I Z Signature /t�G .. Dated%�!9'i� - TOTAL FEE $ Ori Jers';License or SS le Reinspection Fee ,$25, Issue Fee $ 3 PLAN CHECK $• 4•� 'CMF 0865-46 rev. 7/83 ' White-'Building; Canary-Applicant;Pink-Accounting;Goldenrod=Assessor -- -- - .- - . ' --- - - _ CONSTRUCTION AND PLANNING POC SPA APPROVALS Permit# Date Inspector APPROVALS Permit# Date Inspector 4 1. Temporary Electrical Service or Pole 52. Pool & Equipment Location 2. Soil Pipe-Undrgrnd. 9/4.176-5-11e, 53. Steel Reinforcement 3. Electrical Conduit Utility-Undrgrnd. 54. Forms O - 4. Electrical Conduit-Undrgrnd. 55. Electrical Bonding 5. Steel Reinforcement 56. Rough Plumbing & Pressure Test • 6. Electrical UFER Grad. 57. APPROVAL TO COVER-GUNITEi 7. Footings58. Electrical Conduit-Undrgrnd. 8. Foundation • t 59. Gas Pipe, 0 Undrgrnd.,Test / 9. Water Pipe-Undrgrnd. 60. Backwash Lines, P-Trap, 0 Undrgrnd. .1 10. Structural Floor System - 61. APPROVAL TO DECK • 11. Property Sewer Line.& House Conhection L/;0/, /I.1,c 62. Backwash & Receptor-Final • r fJ�I 1 12. Sewer Cap 63. Heater & Vent-Final _ 13. Roof Drains i 64. Plumbing System - Final 14. Rough Plumbing 65. Electrical-Final / 15. Rough Electrical-Conduit 66. Solar System-Final 16. Rough Electric Wiring 04 ,te, 67. Fencing & Access Approval 17. Rough Wiring Sign 68. APPROVED FOR PLASTERING 18. Rough Electrical-T Bar Ceiling 69. POOL/SPA SYSTEMS FINAL 19. Rough Heating & Air Conditioning ((/11l1?5- Gk0 • FIRE DEPT. REQUIREMENT 20. Rough Factory Fireplace APPROVALS Permit# 21. Ducts, in Structure 70. Underground Hydro 22. Ducts, Ventilating 71. Product Piping 0 Gas 0 Oil 23. Gas Pipe;-Rough & Test '72.. Underground Flush 24. Roof;Fiaming 73. Undergrnd.Storage Tank 0 Gas 0 Oil 25. Roof Sheathing 914/e c/v 74. Overhead Hydro 26. T-Bat'Ceiling (Structural) & Monocoat //// 75. Dry Chemical 27. FraMend Flashing /7/ G - IL 76. Dry Standpipe 28. Lath.irig.& Siding (( 77. FIXED SYSTEM FINAL 29. Insulation i (L j(, 1/C. 78. FIRE PREV. FINAL 30. Drywall Nailing l(7J/G C& 78. DEPT. REQUIREMENT 31. Plaster Brown Coat / 79. FINAL INSPECTION 32. Electrical Power Meter-Final a�(��(0 Q� - 80. FOOD CERR/TIIFIC�ATE ISSUED /J 33. Final Electric • /((J Notes:i44 4 . a. wort.,,," 34. Final Heating& Air Conditioning 7_p-g4 va- • ` 35. Final Gas Pipe-Test '1/2/4 4 /// f` 36. Hood or Canopy • 37. Final Factory Fireplace 7-7-11 - 38. Final Plumbing • ? *re ' 39. Water Service-Final 40. Gas Service-Final 41. Solar Domestic-Final ' 42. Backflow Preventer 43. Backflow Irrigation 44. Landscape Irrigation System 45. Sound Attenuation 46. Handicap Regulations 47. FINAL STRUCTURE & BUI LDI NG 314 ✓e- 48. Special Requirements Completed Wiy_/�� (C+ ,fil 49. Electric Release to Edison �V''ff- 50. Gas Release to Southern California Gas Co 'ir. 51. CERTIFICATE OF OCCUPAN it, ani, '••' No. /6 S/ Date r�i �B �,{� � .TAB IS TO MIRY THAT INSutAttON INS situ INSTALLED IN CONrOrNNCE viM nit CURRENT UIENOT REGULATIONS, UILI/OANIA AGVNISTRATIVE MDS. TITLE SS, Of CAL ORRI* 1R TIC SUILDINS LOCATED ATI 2330 VANGUARD WAY, COSTA MESA i3 ( 1031 Strut tot r Tract M. EITERION MALLS Manufacturer MANllil I F iAlclnoaMOO R11 4'/" N P11 till IROS . Manufacturer MANI/11 1 F ThlcMaes R19 n'b" N Value P19 Mown: Manufacturer Thletno, No. Sap Vt./Das Sq. ft. Carse. A Value (LOOPS Manu MANVILLE TM /TM RI1 3'/7" N Valu. R11 SLAB ON GRADE _ Manufacturer Thltano,/Typo • A Value 115th of (molal(.. Inches • rOUloATIDN volts Manufacturer TAI /Type N Valu. GENERAL. CONIMCTOA LICENSE NUMMI SV Tint DATE INSTIUTION CONTMaOA L.A. INSULATION CO. , INC.ucust i.ntu430486 AV a/TITU PRFCIDFNT RATE 1/2p/1z _ - - -