HomeMy WebLinkAbout872 - Adopting M1 Industrial StandardsRESOLUTION NO. 872
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF COSTA MESA
ADOPTING INDUSTRIAL STANDARDS FOR THE Ml, INDUSTRIAL ZONE,
IN THE CITY OF COSTA MESA.
WHEREAS, under the provisions of Section 9295.3 of the Muni-
cipel Code of the City of Costa
Mesa,
the
City is
required to adopt
certain industrial standards in
order
to
promote
the orderly development
of M1, Industrial Zone, properties; and
WHEREAS, the Planning Commission of the City of Costa Mesa
has approved said Industrial Standards, which are attached hereto and
by this reference made a part hereof; and
WHEREAS, this Council deems it to be in the best interest
of the City that said industrial standards be approved, ratified, and
adopted.
NOW, THEREFORE, BE IT RESOLVED, by the City Council of the
City of Costa Mesa, that said industrial standards entitled: "INDUSTRIAL
STANDARDS, CITY OF COSTA [ESA", attached hereto and by this reference
made a part hereof, be, and the same are hereby, approved, ratified and
adopted as the industrial standards of the City of Costa Mesa.
PASSED AND ADOPTED this 7th day of August, 1961.
Y
Mayor a4eo h of Costa Mesa
601
ATTEST:
City Clerk or the Cit of Costa Mesa
STATE OF CALIFORNIA )
COUNTY OF ORANGE ) as.
CITY OF COSTA MESA )
I, A. C. SWARM, City Clerk of the City of Costa Mesa, hereby
certify that the foregoing Resolution No. 872 was duly and regularly
passed and adopted by the City Council of the City of Costa Mesa at a
regular meeting thereof held on the 7th day of August, 1961.
IN WITNESS WHEREOF, I have hereunto set my hand and affixed
the Seal of the City of Costa Mesa, this 8th day of August, 1961.
.4.7z�
City Clerk and ex -officio Clerk of
the City Council of the City of
Costa Mesa
�Chief Deputy
U24A
RESOLUTION 872
4. Correction Factor.
The corrections set forth in Table II shall be made when
applicable.
Resolution 872
Exhibit
1 OF 10
NOISE STANDARD
1. Noise Measurement Points.
Noise shall be measured along each property line of
the property
at at least two points or at as many more points as
may be determined
necessary by the Planning Department.
2. Methods of Noise Measurement.
Noise level shall be measured with a Sound Level Meter
and an
Octave Band Analyzer conforming to specifications set
forth by
the American Standards Association.
3. Maximum Permissible Noise Level shall be as follows;
TABLE I
Frequency Band Sound Pressure Level
Cycles per Second Decibels
re 0.0002 Dyne/CM2
20-75
69
75-150
54
150-300
47
300-60o
41
60o-12oo
37
1200-2400
34
2400-4800
31
4800-lo,000
28
4. Correction Factor.
The corrections set forth in Table II shall be made when
applicable.
Resolution 872
Exhibit
1 OF 10
14248
TABLE II
Type of Operation or Correction
Character of Noise in Decibels.
Day time operation only + 5
Noise source operating less than
20%i of any 1 hour period + 5 *
Noise source operating less than
5% of any 1 hour period + 10 *
Noise source operating less than
1% of any 1 hour period + 15 *
Noise of impulsive character - 5
(hammering etc.)
Noise of Periodic Character - 5
* Apply one of these corrections only
Area Classification j
Adjoining Residential District - 10 J
Adjoining Professional District - 5
Adjoining Industrial District 0
Adjoining Commercial District 0
NOTE: Where different district adjoining said industrial use, an
average of all corrective factors shall be determined and
used.
Resolution 872
Exhibit
2of 10
1424C
VIBRATION STANDARD
1. Vibration Measurement Points
Vibrations shall be measured along each property line of the property
at at least two points or at as many more points as may be determined nec-
essary by the Planning Department.
2. Method of Vibration Measurement
Vibrations shall be measured by the Vibration Meter (Type 761-A)
3. Maximum Permissible Vibration Level
The Maximum Permissible Vibration Level shall conform to Diagram V.S. I.
Resolution 872
Exhibit
3 of 10
1424D
Resolution 872 - Exhibit 4 of 10
1424E
SETBACK AND HEIGHT STANDARD
Abutting
Zoning
District Front Side Rear
Al AS 1' X H 2' x H
RIE PER 3' x H 3' x H
R1 ORDINANCE 2' x H 2' x H
R2 and 2' x H 1' x H
R3 PLANNING 2' x H 1' x H
A COMMISSION 3' x H 2' x H
AP and 1' x H -0-
cls TRAFFIC -0- -0-
C1 COMMISSION -0- -0-
C2 RESOLUTIONS -0- -0-
P -0- -0-
I &R 3' x 3' x
M -0- -0-
H= Height of Industrial Structure including Accessory Structures.
Resolution 872
Exhibit
5 of 10
VEHICLE INGRESS & EGRESS STANDARDS
Vehicle ingress and egress shall be as follows;
1
- 50
Employees
51
- 100
Employees
101
- 150
Employees
151
- 200
Employees
201
- 250
Employees
251
-
FRONTAGE OF INDUSTRIAL SITE
50
or less
51
- 150
151
300
301
450
450
+
1 curb
cut
2 curb
cuts
4 curb
cuts
6 curb
cuts
8 curb
cuts
One cut
for ee.ch 50 persons
additionally employed.
1 curb cut
2 curb cuts
4 curb cuts
6 curb cuts
One additional curb cut
per 75' of frontage
Curb cut construction shall conform to City Specifications.
Location of curb cuts and distances from each other, shall be subject to
the approval of City Engineering Department.
Curb Cuts, as set forth in this standard, shall be eight (8') in width
(measured at bottom of cut).
Resolution 872
Exhibit
6 of 10
1424G
AIRBORNE PARTICLE STANDARD
1. Measurement Points.
Airborne particles, including odorous gasses and other odorous matter,
shall be measured at the property line or some other windward locations.
2. Method of Measurement.
Airborne particles shall be
measured by the
Ringleman
Chart.
3. Maximum Permissible Airborne Particle Level.
The maximum permissible airborne particle level shall not exceed
#1 on the Ringleman Chart.
Resolution 872
Exhibit
7of10
STCRAGE STANDARDS
A. Open Storage-- shall conform to Diagram S-1 or S-2, whichever
is applicable.
B. In no event shall open storage exceed the permitted height of
fences.
C. Dead Storage -- means storage placed in a given area for more
than 14 days.
Resolution 872
Exhibit
8 of 10
1424 R
ABUTTING RESIDENTIAL ZONE
DEAD OPEN
25% OF PERMITTED
STORAGE ONLY
STORAGE AREA
DEAD OPEN
STORAGE
25% OF TOTAL
T
u
LOT DEPTH
LIVE OPEN STORAGE
PERMITTED
COMPUTED BUILDING
I
SETB4CK LINE
LANDSCAPE AREA I1
EQUAL TO BUILDING
SETBACK - 10'MINIMUN
STREET
.OUE FENCING
6' HIGH
LLJ
Ld
SI
STANDARD SPECIFICATIONS
INDUSTRIAL STORAGE
CITY OF COSTA MESA
RLsolution 872 - 9 of 10 - Exhibit
1
i
J
1424I
ABUTTING COMMERICAL
OR INDUSTRIAL ZONE
OPAQUE FENCING
6' HIGH
PERMITTED OPEN STORAGE AREA
25 % OF TOTAL
LOT DEPTH
NO OPEN STORAGE
W
PERMITTED LANDSCAPE AREA Ld
EQUAL TO BUILDING
SETBACK - 10 MINIMUM
U)
STREET
S2
STANDARD SPECIFICATIONS
INDUSTRIAL STORAGE
CITY OF COSTA MESA
Resolution 872 - Exnibit - 10 of 10