Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3120 TAFT WAY - Building Permits
PBOJECTADDRESS: 3120 TAFT WY UNIT: • CITY OF COSTA. MESA — BUILDING PERMIT PERM NO: B 054189 ! .OWN^S NAME: JENKINS, MICHAEL J V- at' V- GAIL E PERMIT NO: B 054189 PLAN CHECK NO: 03844-91 S GOVT: N SUPP: N • 3120 TAFT WY COSTA MESA,CA 92626 CONSTRUCTION TYPE: V—N PERMIT TYPE: STR PURPOSE: OTH 751-4115 ARCH/ENGINEER: REG.ND.: JOB DESCRIPTION : CITY STD PATIO COVER ', SQ FT: 324 ADDRESS: UNIT: CLAIM VALUE: 950 . 00 CALC—VALUE: 4, 471 . 20 GROUP OCC; R-3 / PERMITTEE: JEFFREY N FRAWLEY ( 714 ) 557-3443 ADDRESS: 1152 SALINAS AVENUE COMMENTS: SMOKE DETECTOR REQUIRED IN THE HOME COSTA MESA CA 92626 *********x*aH****iE***x****** *aE**+F****** ** ***** ****************aF****** N *+I** LICENSED CONTRACTOR DECLARATION: I hereby affirm that I am licensed under provisions of Chapter 9(commencing with Section Z ONING REQUIREMENTS 7000)of Division 3 of the Business and Professions Code.and my license is in full force and effect. SETBACKS CITY UC.: 045091 STATE IC.: 481626 CLASS: : l' 9"9l Signature: MAIN BUILDING ACCESSORY BUILDING �e1e g FRNT: 20 FT IN REAR: 21 FT IN FRNT: FT IN REAR: FT IN WORKERS'COMPENSATION DECLA'ATION: thereby affir t .t ha , .certificate of consent to self-in Ar a certificate of Workers' LEFT: 9 FT 6 IN RGHT; 20 FT IN LEFT; FT IN RGHT: FT IN Compensation Insurance,or a certi ed copy thereof(Section 3800.Lab. C). POLICY NO.: EXP. DATE: COMPANY: PARKING RE • PROV: PARCEL: 14169318 ZNE: R1 REF NO: CI Certified copy is hereby furnished . LI Certified copy is filed with the city Building Division. PLANNING NOTES> 324 SQ. FT. PATIO COVER TO AN EXISTING RES. > Date' Applicant: *********************************************************************arse********* EXEMPTION FROM WORKERS'COMPENSATION DECLARATION: (This section need not be completed if the permit is for one hundred($100)or less). DEVELOPMENT SERVICESR E Q U I R E M .E NzT S I certify that in the performance of the work for which this permit is issued,I shall not employ any person in an manner so as to become subject to the Workers'Compensation Laws 01 California. , ZONING APPROVED BY DATE: r Date: !`��['J T7 Signature --4.4.1 / sifL� ' �— NOTICE:If,after making this declaration,you should b. r ibj jX o the Workers'Compensation/isions of the Labor BUILDING APPROVED BY : „ DA 1 E: - ,, ' Code,you must forthwith comply with such provision' or '. pe P� shall be deemed revoked. CONSTRUCTION LENDING AGENCY: I hereby affirm that there is a construction lending agency for the performance of the work for APPLICATION ISSUED BY; DATE. .1' e which this permit is issued(Section 3097.Civ.C). ************************** ********** • • • • • • ** LENDER: ****************************************** ********************************* ADDRESS: LEGALIZATION:N F E E SUMMARY STRUCTURAL SEGMENT:Y OWNER BUILDER DECLARATION: I hereby affirm that I am exempt from the Contractors'State License Law for the following reason BLDG PMT PLUMBING ELECTRIC MECHANIC F IRE SMI P/RES GRADING (Section 7031.5 Business and Professional Code: Any city of county which requires a permit to construct,alter,improve,demolish,or PERMIT 72 . 0050 . repair any structure.prior to its issuance.also requires the applicant for such permit to file a signed statement that he/she is licensed SMIP/NON—RES pursuant to the provisions of the Contractors'State License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business PLAN ,4 6 . 8 0 'nd Professions Code)or that he/she is exempt therefrom and the basis for the alleged exemption.Any violation of Section 7031.5 by iv applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500). ISSUE FEE BUILDING—DIV—> PERMIT ISSUE PLAN—CHECK TOTAL PAID DUE I, as owner of the property or my employees with wages as their sole compensation, will do the work, and the TOTALS----> 72 . 50 0 . 00 46 . 80 119 . 30 119 . 30 . 00 ❑ structure is not intended or offered for sale(Section 7044,Business and Professional Code: The Contractors'State License Law does not apply to an owner of a property who builds or improves thereon,and who does such work himself/herself or through his or her own employees,provided that such improvements are not intended or offered for sale.If, however the building or REVENUE DIVISION TOTALS--> COLLECTED : 119 . 30 OVER/SHORT: 00 improvement mrpot is se sold wt. s ithin one year of completion,the owner will have the burden of proving he/she did not build or improve BLDG PMT PLUMBING ELECTRIC MECHANIC FIRE SMIP/TOT GRADING PLAN—CHECK for the purpose uensale). I,as owner of the property.am exclusively contracting with licensed contractors to construct the project(Section 7044.Business 72 . S 0 46 . 80 ❑ and Professions Code: The Contractors'State License Law dries not apply to an owner of property who builds or improves thereon and who contracts for such projects with a contractor(s)lictnse pursuant to theContractors'State License Law).l am aware **3 ***-**************'******'********************'**IE********'********************** that proof of their Worker's Compensation insurance should be provided to me. INDIVIDUAL F E E BREAKDOWN o I em exempt under Section: B.8.P.C. for this reason: TYPE QTY DESCRIPTIO N UNIT COST TOTAL COST • Date: Owner: SFR 324 RES—PATIO COVER—POST & TRELLIS 13 . 80 4 , 471 . 20 I do hereby certify that I am aware of and understand the requirements of California Health and Safety Code Sections 25505.25533,and END OF FEES . 25534 and that I or any future building occupant will/will not(circle orae)need to comply with said state codes and the requirements for a permit for construction or modification from the Air Duality Management District.Residential construction applications are exempt from these provisions. Date: Applicant: I hereby certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction and hereby authorize representatives of this city to enter upon the above-mentioned I property for eC/ inspection purposes. nI. ,,. r3 - 9/ Signature: ,ii.. /' itwQ S' ;:', C:C Zx427-.:PT?8 1 T Jr . . i(': Driver's License or Social Security e: . : / -iy+`. s9y4D:91 I:hi )'::7U 7 164146 white—Budding;Green—Code EntorcemenL Canary—Applicant Pink—Revenue;Goldenrod—Assessor . y , .TT'CONSTRUCTION AND PLANNING POOL & SPA ' ' APPROVALS Permit# Date Inspector APPROVALS Permit Date Inspector 1._Temporary Electrical Service or Pole - 52. Pool & Equipment Location . 2. Soil Pipe-Undrgrnd. 53. Steel Reinforcement 3. 'Electrical Conduit Utility-Undrgrnd. 54. Forms . • -4.-Electrical Conduit-Undrgrnd. 55. Electrical Bonding 5. 'Steel Reinforcement 56. Rough Plumbing & Pressure Test 6. Electrical UFER Grnd. _ 57. APPROVAL TO COVER-GUNITE ' 7. Footings 58. Electrical Conduit-Undrgrnd. 8. Foundation " . - 59. Gas Pipe, 0 Undrgrnd.,Test ' 9. Water Pipe-Undrgrnd. 60. Backwash Lines, P-Trap, 0 Undrgrnd. 10. Structural Floor System 61. APPROVAL TO DECK 11. Property Sewer Line & House Connection 62. Backwash & Receptor-Final • - 12. Sewer Cap 63. Heater & Vent-Final 13, Roof Drains s 64. Plumbing System - Final 14. Rough Plumbing ' 65. Electrical-Final ' 15. Rough Electrical-Conduit 1 66. Solar System-Final • 16. Rough Electric.Wiring 67. Fencing & Access Approval 17. Rough Wiring Sign 68. APPROVED FOR PLASTERING 18. Rough Electrical-T Bar Ceiling 69. POOL/SPA-SYSTEMS FINAL 19. Rough Heating & Air Conditioning FIRE DEPT. REQUIREMENT 20. Rough Factory Fireplace .APPROVALS Permit # 21:Ducts, in Structure 70. Underground Hydro 22. Ducts,Ventilating - , 71. Product Piping ClGas ❑Oil 23.-Gas Pipe-Rough & Test - 72. Underground Flush , 24. Roof Framing -.73. Undergrnd.Storage Tank-O Gas 0 Oil 25. Roof Sheathing _ ,r 74: Overhead-Hydro 26. T-Bar Ceiling (Structural) &Monocoat - 75.- Dry Chemical J • 27. Frame and Flashing " • - 4. 76. Ory Standpipe 28. Lathing & Siding .- - 77: FIXED SYSTEM FINAL ' 29. Insulation - - ' 78. FIRE PREV. FINAL - 30. Drywall_Nailing .• .. i HEALTH DEPT. REQUIREMENT 31. Plaster Brown Coat ' / 79," FINAL INSPECTION '32. Electrical Power 'Meter-Final . 80. FOOD CERTIFICATE ISSUED 33. Final Electric - ' - ,- Notes: - 2;34. Final Heating &"Air Conditioning - : ` / ,. . 35. Final Gas Pipe-Test+ - .f.- - ' ..36. Hood or Canopy, • : 37. Final Factory Fireplace • ' ,. , • ' 38..Final Plumbing ., :i - , r . - J . 39. Water Service-Final 40. Gas Service:Final - „ . 41. Solar Domestic-Final-, - - - • 42. Backflow Preventer ft ,:, , - 43. Backflow Irrigation - - "- rt _ -,44. Landscape Irrigation Systs ,' rrZ , .� 45.'Sound Attenuation _ " - 1 { - 46. Handicap Regulations - : ' 47.,FINALSTRUCTURE & BUILDING- ` l f -fl ;' . 48. FINAL PLANNING J ' 49. Electric Release to Edison - ' 50, GasRelease to Southern California Gas Co i - '- :51. CERTIFICATE OF OCCUPANCY / - No. Date .l I _p—• NOTE: SHOW AND DIMENSION PROPOSED PATIO COVER AND YARD AREAS FOR INSPECTIONS I • ---..N SEE DETA LS ON REVERSE SIDE It p C -�- -- ? - - I APPRei D • 754-5626 (Z City of Costs (V'12z Bj'•� .�•• • -•OF SHEATHINGOf • 1 - 'S' 754-5627 T �r f ries T IESE PLANS MUST IE ON J08 ' ALI flux ,4AI,�AF ERS J "•••. �a9�by JO NC CHANGES WITHOUTPRIOR A• ROVAQ C F frtitT. „` cf.. LZ. --> I TIE ISSUANCE OR GRAN,INC OF PE i•IT OR APPROVAL OFFA t „_\_/_\i j, PLANS AND SPECIFICATIONS •'_ ONL' BE A PCI MIT FOR, OR AN APPHCVSHALLA( OF WU$`Jy 'LITIONSTHOFED ANY10OF —X_ BEAM THE PROVISIONS OF Th IIS CC DE.NO la I.T 'RESUMING TO GIVE T-STRAP EA. SIDE AUI IORIFY TO VIOLATE. OR CANCEIy HE 30VISIONS OF THIS FOR POST- BEAM Ts- t. 'COVE SHALL BE VALID EXCE 'TIN SOARK WHI:H IT AUTHORIZES IS LAY HA. `- THE WORN OR USE .CONNECTION. o ;O z x a F U LHE ISSUANCE OF A 1 EHMIT SFS UPON PLANS AND Q w Z SRE;IFICATiO;JS SHALL NOT PREVE 11 BUILDING OFFICIAL IL W Q Li FRO,FTHEREAFTER REOUIHV IG THE( m I- ~ o Z ITq. TION OF ERRORS IN Q co a N C SAID FLANS AND SPECUFLATIONS OR F ROM PREVENTING 0. A BUMLLING OPERATIONS BEIM.CAPRAF0 0 iEREUNDER WHEN m m m n ! -p l 1�i _-_ ._j, SH `L IN Vt,XATICN OF THOS CODE DR OF dfly •� - p ,V� DR GORE EPpRSM THE ITV. x .�ER O7TDINANCE OF Z m It Z r pNs, DEBU\ S\-- IASI p1 PNl�1NG D I. O = ”0 wow w Dp1j� gV • DROP PATIO w LL i x .j z p ABE NpPRpJcD FLOOR 2" z p a n n M a 'Ip 099�/o I 1 / ETO IN PLATE ABOVE SLA ----#.1-- SMOKE DETECT iii." ..'' '.. ...... ... . ;aJQ `N 26 GA. G. I. FLASHING • ry,/ 1IEE3�__ REQU RED " lfli I STA WOOD FLOOR ��__ J PIANNING_D�T. CONSTRUCTION PIERS 12" SOJi w cc SUBJECT TO IDO. DSL IN. 'C Q ^/ 0 �Y_... DA1 Permit * 8 5 y/ rF i i Nona OP MANNINO I� S I REIT THIS NUMBER MUST �y • "PXLEVATION ALL INSPECTION R �� T PLOT PLAN CONSTRUCTION DETAILS 2011>6.ROOF CONNECTION DEVELOPMmP' PATIO COVER '6 DETAILS SERVICES D2r 'r CONT. BUILDIT7G SAFETY DIVISION TYP PLANS SOLID BLOCK LEDGER • I • RAFTER OWNER: DATE : ADDRESS: PHONE: 1/2" DIA. X 5" LAG SCR. CONTRACTOR: LIC. NO. AT 32" O.C. ADDRESS: PHONE: DETAIL I RAFTERS RAFTERS APPROVED FOR CARPORT, PORCH OR PATIO LIGHT WEIGHT ROOF COVER OF BUILDING PERMIT NOT SUPPORTING CEILING LATH, FIBERGLASS, ALUM. By Date SIZE. SPACING SPAN SIZE SPACING SPAN CR a CL "TECO" 2"x4" 12"O.C. 9'-6" 2"x4" 16"O.C. 9' -6" GRIPS OR JOIST 16" 8' -0" 24" 8' -0" SRNERAL NOTES: HANGER 24" 6' -6" 32" 6'-6', 1. These plans must be CONT. ..... 32" 6'-0" 48" 5'-6" kept im the job at LEDGER I',� 48" 5' -0" 2"x6" 16" • 16'-6" all .time during 2"x6" 12" 16' -6" 24" 14'-6" construction. 16" 14' -6" 32"• 12' -0" 2. All framing to be n 24" 12' -0" 48" 10''-0" Douglas Fir N9. 2 3/8 DIA. X 5" LAG SCR. ,- „ grade minimum. 32" 10' -6" 2"x8" 24" 19 0 AT (b ' O.C. 48" , 8' -0" 32" 15'-6" 3.. Rafters may not DETAIL 2 2"x8" 24" 15' -6" 48" 13'-6" attach to facia ex 32" 13'-6" sept for l0166roofs 48" 11'-6" -. as shown on 'details; 101650R LIGHT WEIGHT ROOFS 4"x6" 24" 17'-O" • ,. HEADERS, '4Cie . . 204,aroofs must use ONLY CONNECTION DETAILS 32" 15'-O" LIGHT WEIGHT ROOF ONLY a continuous ledger 36" 14' -0 _— attached as shown 2" X FACIA-MI N. REO. 4"x8" 24" 21 ' -0" SIZE POST SPACING ' on details #l$#2. 32" 19' -O" 4x4 6. -0 4. Light weight roofs 36" 18'-O" 4x6 , 9' -O" may aattach to facia �� 48" 16'-O': ' 4x8 12'-0'; for 14' span max. , ®_// RAFTER 4",x10" 32" . 22'-0" 4x10 T -15--'.-0" -' spans over 14' must 36" 21'-0" use a continuous CARPORT, PORCH OR PATIO ledger as shown in 48" 20' -0" SIZE POST SPACING APPROVED METAL - detail #3. HANGER 72" 17'-0" 4x4 5' -0" 4x6 . 8'-0" —lc- DETAIL 3 4x8 10'-0" 4x10 12'-6" 0.0.8411N - 2'9 ' Applicant to fill in all spaces except those within heavy border lines and sign all appropriate declarations. ��- 4./e , er LOT UNIT NO. CITY OF COSTA MESA CONSTRUCTION PERMIT PER IT NO $ TR . T NOl& A.P.# 'LL{ -6q -1� Zone r1 Project tiddress a 1 '>1-T• (A Ni ESP S Main Building: Accessory Building: 74pplicant's Mailing Address 3120 TYTFT6�9, C•C.M• g26 ZOO TYPE OF CONSTRUCTION LI NEW U ADD U ALTERATION U REPAIR E Z Front ❑ CONVERSION ❑ DEMOLISH ❑ OTHER Y I 0 0 OwnI.er's Name l hCHAFt 6 CitUL i£W K 1/VS Phone 15 1 -4l!(� DESCRIPTION OF WORK/USE OF BLDG. - .. . . A Rear lb6 fC N Address • 3113 —4FT LNA/7 0- IYI, CPI- gat a7C., '4: -v. I C Ri ht ! N Arch/Enb. .j•t•IE License No. — TYPE OF PERMIT ❑ GRADING LJ FOUNDATION U STRUCTURAL K g sO - SJc?v'nt ❑ TENANT Left g"/4 (f G Add''ess El ❑ PLUMBING III MECHANICAL S t R Contractor's Name 5/i 1 e -Phone-751-411$' ❑ OTHER r n-1 I Ping. Ref.# Parking Req./Provided E PROJECT DESCRIPTION SQ. FT. Set(/ OCCUPAN�(/_K— O PlanningNotes: ,,y�/ / J Address(mailing) $♦4✓YI L VJ ' 2� r Cali I Lit C� '" Xir1 s't(I M 0 ''n/ CON ST RUCTION TYPE \I 1•1 VALUATION$ �osIs City License No. �( �? ZONE GRADING CU.YDS. ACRES 5:41.7 ( P a/Ms c/ �'CC 1 I j), S. LICENSED CONTRACTOR DECLARATION (7„,4,4 //� J I•hereby affirm that 1 am licensed under provisions of Charter 9 (commencing Remarks: f ' L b . (� 1'�1 vs V� PIA �`� . - i Q with section 7000) of Division 3 of the Business and Professions Code,and ' ` '�`'� ` 1 ` \ 'a my litems is in full force and effect. (")/ Z3�-e ELECTRICAL FEES y zn ze_�iass License No. r l Automatic Washer Transformer 0 15-50 KW Y Signature PLUMBING FEES s, COMPENSATION DECLARATION /'r� �1 COnstr UctiOn POIe sub. 0 50+ KW I herebybffirm that I have a certificate of consent to self-insure or a certificate Bar Sink Showers �1 4 of Workers' Compensation Insurance, or a certified copy thereof (SectionBackflow Preventer. Service Sink Cooking Unit Meter ❑up to 100 amps 3800, Lab. C.) . - .. ' Policy No. Company - Backflow Irrigation Sewer Cap Dishwasher Meter Dover 100 amps _ Certified copy is hereby furnished. '- Drrs ❑Gas ❑Electric — — Certified copy is filed with the city Building Division. • Bathtubs Sewer Connection (10 • 5 yeSub Panel Date Applicant' Fan ' EXEMPTION FROM WORKERS'COMPENSATION DECLARATION Clarifiers Solar Collectors • Motors❑0-1 H8 3 N (This section need not be completed if the permit is for one hundred ($100) or F.A.U. - Inc.Solar 09-15 HP 01605+ less). - Dishwasher Solar Piping I certify that in the performance of the work for which this permit is issued I �/ Fixtures (tip Microwave shall not employ any person in any manner so as to be ome subject to the Drinking Fountains Solar Tank - ^ ® ti _ 3 ~ Workergq num r��t ion,caws of Califggqq((((gggga. p (I Device Boxes Pole Light Date Ez• f / s4 1 Signature k�C..a,Q ,enJ Lti- ( Floor Drains Swimming Pool w/Spag - NOTICE; If,atter making this declaratio ,you sho d b ome subject to the - �OUt ets ® Range 3 Workers' Compensation provisions Of the Labor C ' you must forthwith Floor Sinks Urinal 7S comply with such provisions or this permit shall be deemed revoked. X. //��) CONSTRUCTION LENDING AGENCY Gas Service Outlets ^ Water Closet ( ) � _ Switches d� Sign f 5-0 1 hereby affirm that there is a construction lending agency for the performance Garbo ¢DIS OSa of the work for which this permit is issued (Section 3097 Civ. C.) Interceptors Water Heater 9 p Standing Sections • Lender's Name Lender's Address Kitchen Sink Water Service _ Generator ❑0.5 KW 05-15 KW Trash Compactor OWNER BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the Lavatories Auto-Wash {Mowing reason (Section 7031.5 Business and Professional Code: Any city or 'x,„nty which requires a permit to construct,alter,improve,demolish or repairP-Trap Laundry Trays • ' ;'structure, prior to its issuance, also requires the applicant for such permit " 4:'tile a signed statement that he/she is licensed pursuant to the provisions of Roof Drains I c--,(I!a.Contractor's License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code) or that he/she is exempt - Reinspection Fee $15 Issue Fee -$$' therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500). DEVELOPMENT SERVICES REQUIREMENTS: _ I, as owner of the property or myemployees with wages as their sole Reinspection Fee $15 Issue Fee ZoningApprovedBy $ 3 T - Date compensation,will do the work, and the structure is not intended or offered - -for sale (Section 7044, Business and Professional Code: The Contractor's MECHANICAL I FEES • Building Approved ByDate License Law does not apply to an owner of a property who builds or improves !�L / —I_.Q O thereon, and who does such work himself/herself or through his or her own - Application Issued By UPC Date( employees, provided that such improvements are not intended or offered for Boiler Hood or Type I 0 sale. If, however, the building or improvement is sold within one year of com- Canopy Type II 0 - SUMMARY OF FEES pterion, the owner will have the burden of proving he/she did not build or im- Duct-Under Ground - BB roe for the purpose of sale). • BUILDING PERMIT $ Z�i SMIP $ PERMIT I I, as owner of the property, am exclusively contracting with licensed con- Duct-Structural Refrigeration System PLAN CHECK $ rectors to construct the project (Section 7044,Business and Professions Code: The Contractor's License Law does not apply to an owner of property who Duct-Ventilating 00-100,000 BTU 0100,000 BTU PLUMBING $ 12-i ISSUANCE $ builds or improves thereon.and who contracts for such oroiects with a con- tractor(s) license pursuant to the Contractor's License Law). I am aware that Exhaust System 0 Multiple 0 System Repair/Alteration PLAN CHECK 25% $ / _ ENERGY P.C. $ proof of their Worker's Compensation insurance should be provided to me. ELECTRICAL $ 'Z�.Zs GRADING $ 0 I am exempt under Section B.& P.C.for this reason Firepl/Fact.Blt. ICBO dk Fire Dampers MICROFILM $ ��A�� flB 1,, PLAN CHECK 50% $ Date s .�Owner N"c'Y"-t (am�L1_.-_ i Heating System& Ducting Registers MECHANICAL $ 3risl3 I hereby certify that I have read tt is applic . n nd state that the above 00-100,000 BTU 0100,000 BT TOTAL FEE $ information is correct. I agree to comply with all city and county ordinances _ PLAN CHECK 25% $ _ and state laws relating to building construction, and hereby authorize repre- . sentatives of thi city to e ter upon the above-mentioned property for inspection our k. s. j •r Signature ai . __ • 'i. — Dates ` • . - ��1 1','.9-'. .,l Drivers' License ,r 55 / / Reinspection Fee $15 Issue Fee $ 3 b CCL. ����-1- ��a ' 0865-46,rev. 5/8: White - Building; Canary - Applicant; Pink -Accounting; Goldenrod - Assessor J i :CONSTRUCTION AND PLANNI. SOL&STA '� ,,, - Date Inspector • - Date Inspector APPROVALS Permit#--�- APPROVALS 'Permit# 1. Temporary Electrical Service or Pole - 52. Pool & Equipment Location 2p Soipe-Undrgrnd. il P53. Steel Reinforcement 3. Electrical Conduit Utility-Undrgrnd. 54. Forms - 49 Electrical Conduit-Undrgrnd. r 55. Electrical Bonding 5. Steel Reinforcement //// 56. Rough Plumbing & Pressure Test 6: Electrical UFER Grnd. y 2.1 p 14- • 57. APPROVAL TO COVER-GUNITE , . 7. Footings' 3 s --c4-c, 7,4 #714_ - 58. Electrical Conduit-Undrgrnd. - 8.'Foundation '. 59. Gas Pipe, D Undrgrnd., Test . 9:.Water Pipe-Undrgrnd. � / 60. Backwash Lines, P-Trap, 0 Undrgrnd. ( • 10. Structural Floor System '' Lt[ ¶ 0-k, 61. APPROVAL TO DECK • 11. Property Sewer Line & House Connection ` 4. 62. Backwash & Receptor-Final • 12.' Sewer Cap , - • 63. Heater & Vent-Final . 13. Roof Drains _ -64. Plumbing System - Final • 14. Rough Plumbing . se. tort ,1151&• I 65. Electrical-Final 15. Rough Electrical-Conduit 66. Solar System-Final • l6: Rough Electric Wiring 67. Fencing & Access Approval 17. Rough Wiring Sign 68. APPROVED FOR PLASTERING ' 18. Rough Electrical-T Bar Ceiling 69. POOL/SPA SYSTEMS FINAL 19. Rough Heating & Air Conditioning Vert* ..J FIRE DEPT. REQUIREMENT 20. Rough Factory Fireplace .. 7 APPROVALS Permit# 21. Ducts, in Structure 70. Underground Hydro 22. Ducts, Ventilating ... _ 71. Product Piping D Gas 0 Oil 123. Gas Pipe-Rough & Test • - 72. Underground Flush 24. Roof Framing - . {t B 73. Undergrnd.Storage Tank 0 Gas 0 Oil 25. Roof Sheathing65 Y W 74. Overhead Hydro 26. T-Bar Ceiling (Structural) &.Monocoat 75. Dry Chemical 27. Frame and Flashing 76. Dry Standpipe X28. Lathing& Siding - 177! FIXED SYSTEM FINAL 29. Insulation 78. FIRE PREV. FINAL • • 30. Drywall Nailing - dql- HEALTH DEPT. REQUIREMENT 31. Plaster Brown Coat' ' - �j, 79. FINAL INSPECTION 32. Electrical Power Mgter-Final 80, FOOD CERTIFICATE ISSUED '33. Final Electric ). Z+•1 ' O t Notes: 7/7 /Sr9 rj ,‘,.. D 34. Final Heating & Air Conditioning •, 9,,-(firord t/01443f, 045 otisTecx-TeRtjnEsr, • 35. Final Gas Pipe-Test 136. Hood or Canopy _ =WW ,/ / i Bat 37. Final•Factory Fireplace . '38. Final Plumbing LE/0 % '• ' 39. Water Service-Final . '.40. Gas Service-Final 41. Solar Domestic-Final ‘ 42. Backflow Preventer • ` ! • 43. Backflow Irrigation_ • • 44. Landscape Irrigation System , 45. Sound Attenuation • 46. Handicap Regulationsli-Cfil, ea., ' . 1 i. 47. FINAL STRUCTURE & BUILDING r ._ J. 48. Special Requirements Completed i r vs- 49. Electric Release to Edison / ' 50. Gas Release to Southern California Gas Co • 51. CERTIFICATE OF OCCUPANCY - , No. Date _ ' r , I City of Costa Mesa MEASURE "G" EXEMPTION Plan Check # _ 235-89s Exemption # 89-469 Permit # Case # Address: 3120 Taft Unit: Applicant: Michael Jenkins FACTS: x❑ Residential ❑ Commercial/Industrial ❑ Other Existing Lot ❑ Not Part of Larger Project Project Description: 120 sq.ft. room addition to existing single family dwelling No. of Dwelling Units NA Gross Floor Area NA Square Feet F.A.R. NA Estimated Traffic Generation:NA Avg. Trips/day FINDINGS: The above described project is exempt from compliance with Measure "G" for the following reasons: n 1. Project is a commercial/industrial development which meets all of the following criteria: gross floor area is equal to or less than 10,000 square feet or has an average daily trip generation of less than 130 daily trips, has buildable floor area ratio of less than 0.5, on an existing lot, and is not part of a larger project. ❑ 2. Project is a residential project of four dwellings or less on an existing lot. E 3. Project is residential construction that does not increase the number of permanent housing units on the parcel where the construction takes place, such as remodeling or rebuilding of an existing house. ❑ 4. Project is commercial/industrial construction that does not increase the footprint or square footage or change the use on the parcel where the construction takes place, such as remodel- ing or rebuilding an existing structure. • n 5. Project is a public benefit facility, which is defined as public libraries, public administration facilities, public parks, public utilities, and religious facilities. ❑ 6. Project is a facility serving the health and safety of the people, which is defined as hospitals, police, fire and safety facilities, and schools. Exemption ratified by: n Planning Commission Date May 22, 1989 ❑ City Council Date 1 fliiIa 1648.30 - .-� CITY OF COSTA MESA CALIFORNIA 92628-1200 P.O.BOX 1200 Insulation Certificate 3i 2-b rcwr w'y Co Sin ' kF_SA Number and Street ity a2A/kJlS DOS 2 County Subdivision Lot Number Description of Installation • ROOF Material Brand Name Thickness(inches) Thermal Resistance(R-Value) EXTERIOR WALL Material —lPbEWLl,u4K s I n rILt Brand Name Uwe lS / CO2Ni rlJL Thickness(inc les) Thermal Resistance(R-Value) R- ] CEILING Batt or Blanket Type Brand Name 0 we u G / Ccstn/e NL> Thickness(inches) Thermal Resistance(R-Value) R — 3 n Loose Fill Type Brand Name Contractors minimum installed weight/ft2 lb Minimum thickness inches Manufacturer's installed weight per square foot to acheive Thermal Resistance(R-Value) RAISED FLOOR Material Brand Name Thickness(inches) Thermal Resistance(R-Value) SLAB FLOOR Material Brand Name . Thickness(inches) Thermal Resistance(R-Value) Width (inches) FOUNDATION WALL Material Brand Name Thickness(inches) Thermal Resistance(R-Value) Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Building Energy Efficiency Standards for new residential buildings contained in Title 24 of the California Administrative Code. si ,: C. tractor(Builder) . License Number and Tide Date V a r(Insulation Installer) Lir a Number 1 _. . a. • i /In/Gf _. S' attre and Title Lire t....RTIFICATE OF COMPLIANCE • ! oz/75/- PAYMENT OF SCHOOL FACILITY FEES NEWPORT-MESA UNIFIED SCHOOL DISTRICT�� Developer/Applicant : Mtc ta2,\ a d Gat\ veh1;14tS • Address : _ 31 `.O Tock{ tax vt C os-1-rA Mes , qZb2‘ 1 Telephone Number : -751 ^ 4 Tract/Parcel and Lot Number(s) : Location of Project : Scu' a 0-S Q1�oJQ. Number of Square Feet of Residential Space 3ci S x $1 . 50 Total1 S93, .' O Number of Square Feet of Commercial and Industrial Space x $0 . 25 Total Commercial/Industrial Project is : (Check One) Mini-storage Motel Preschool Movie Theater Bank Auto Repair Racquet/Health Neighborhood Shops Hospital Warehouses R & D _ Large Office Heavy Industrial Hotel Office Bldg . Regional Shops Medical Office Restaurant Light Industrial Office Park Fast Food The provisions of Government Code Section 53080 are not applicable . This certifies that the above-named Developer/Applicant has paid school facility fees in compliance with Government Code Sections 53080 and 65995 . Checks are to be made payable to New . .rt-Mesa Unified School District . /74 / Bus / ess Manager Newport-Mesa Unified School District The above representation as to square footage is true . Developer/ Applicant agrees that if it is later determined that such representa- tions are not true then this certificate shall automatically terminate and the appropriate City/Countyoshall be notified . • Date : 5 -31 - I /4-tu) Developer/A . licant Gay 1 c"ev, Lois Ii, . 21372 FEE RECEIVED r COSTA MESA BUILDING-SAFETY DEPARTMENT JAN 1 7 1984 P.O.BOX 317 COSTA MESA.CALIFORNIA FINANCE DEPT.en-l/ For Applicant to Fill In Completely APPiTdA+SIaWrit 114f TYPE OR PRINT BUILDING For Office Use Only ADDRESS 3120 Taft Way R[CHIPI NO. j�{Ppt3 7• — COSTA MESA. CALIFORNIA r)c_)•/ R[C[ly[D BY DA [q[C VED DATE ISSUED OWNER Northgate Homes /(/ / -/�� JAN 6 1964 MAIL BUILDING ADDRESS 15939 Las Flores ADDRESS FIRE / � CITY FountainValeylNE 31-6792 ZONE TYPE iY'� GROUP cCiF APPROVED OR ENIG SNEER C. Hiller HO•KE52007 BY DATE Anaheim ZONING r 21 44 ADDRESS — I NO.OP UUEOF NEW. {■i I'/( 1 C I I PUNK I auILDING IAF �/ 'I CONTRACTOR Bonser Const I p. - / _ LEGAL1 / _ Soo` J ADDRESS 15939 Las Flores DESCRIPTION r/ Fountain Valley A.P.NO. CITY • NOTE: NO EAVE OVERHANG SHALL BE LESS THAN STLIC.ANO . 215049 NOL. 5'31-6792 SO"TO SIDE ft REAR P.L. EAVES OF LOT 1Ola60 I NO.OP BLOCS. NOW ON LOT W ALLOWED (U.B.C.REQUIREMENT) YARDS APPROVED YARDS APPROVED USE OF MAIN BUILDING ACCESSORY BUILDING EXISTING BLDG. 00 (FROM 117 S�TREE]P CENTER LINE PROM I 1 FRONT -1 ( -•FT. ` . Fr. cervreR OP(INTERFERE,'"45 REAR YARD 3 SIDE YARD LEFT 51 I RIGHT 5' R.SIDE ) FT. FT. DESCRIPTION OF WORK L.SIDE 4FT. . FT. NEW X ALTERATION ADDITION REAR .�/-J . FT. DISTANCE BET. BET.MAIN 3 REPAIR MOVING y/DEMOLISH MAIN SLOGS. ACCESS.BLOCS. S ZE�INGl2S9 NO.OP ROOMS ✓ STORIES 1 CAU.P.# APPROVED EXTERIOR WALL ROOF APPROVED( I DATE (, C COVERING Stucco I COVERING shingle BY I.lj/ f L'�'� I—/ 7 -6 / USE OF BUILDING AND WORK TO BE PER7ORMER DE, single lam. res w/att/gar. / ((�� !03 So.Fr. — .SGo2& 47'- N I HEREBY AC . -•GE • T I HAVE READ THIS APPLICATION THE AMOUNT SHOWN UNDER VALUATION IS FOR THE F ANO STAT. HAT -O E IS CORRECT AND AGREE TO COM. PURPOSE OP ESTABLISHING A PERMIT FEE ONLY. O PLY WIT ALL •j��''��J�_iiiikAN•ES AND STATE LAWS REGULATING BU IL DIN COrve•i�., , VALUATION i8 d.p PERMIT FEE j PER MITT 5/* 78J _-. ._ . I X / 72 ° 4 AUTHORIZED AGENT TOTAL FEE 5 SEP 16-66 00 LI14A *****3.00 TI >` 26161 • COSTA MESA BUILDING-SAFETY DEPARTMENT P.O. BOX 1200 COSTA MESA, CALIFORNIA 02028 - For Applicant to Fill In Completely APPLICATION FOR PERMIT TYPE OR PRINT BUILDING ■uILDING For Office Use Only ADDRESS 3/a o To F+ 1.44-y RECEIPT NO. 26111?G. COSTA MESA. CALIFORNIA U v OWNER Rtc[{v[�r DAT[RECEIVED6 j{ISSUED .C �/T�`,-�•j� 'nit' r+ ' 1 /M_ /7J�/K_/� '/1/— ESS FIRE CITY (!O.OLN I/I-/ NO. 59e-i 57e ZONE GROU/P�////f/�-,` ARCHITECT CLff y/;^/l� TEL�i// �I��App APPROVED ARCHITECT /DATB %/ /I1/"T` OR ENGINEER 0I . / 0..Q .y NQ.NU-24/!o / �/ I lean Lite}".4.„........4 /! ZONING ADDRESS .3/ /et /I . Lite} ....4 d al •L(, ZONE No.or USE or NEW X�� 51 PLANS ...9_,..1 UDNO /e , CONTRACTOR /^4 _ u a LEGAL ��jj n ((�� ,,I /� 'yam / (' ADDRESS 11109 pl. /l4a.s. F Ja_n.✓�.�-El DESCRIPTION (.Q7` O� �G� d�OJ clrr A.P.NO. a. NOTE: NO EAVE OVERHANG SHALL BE LESS THAN STATE // 7 / g TEL ci jO 2/' SO'TO SIDE a REAR p.L. LIC.NO. d / Ce J d .w' Ctt EAVES SIZE I NO.OPBI.00S. ALLOWED (U.B.C.REQUIREMENT) OF LOT NOW ON LOT YARDS APPROVED YARDS APPROVED USE OP MAIN BUILDING ACCESSORY BUILDING EXISTING BLDG. /,pQis.f (FROM C/-L/SSTRHET)_�/ SETBACK LINE FROM FRONT// FT. A- FT. CENTER OP STREET REAR YARD SIDE YARD I LEFT I RIGHT R.SIDE a 5—IT. FT. DESCRIPTION OF WORK L.SIDE///5Fr. PT.NEW _ ALTERATION ADDITION I DEMOLISH I L� REAR / ' PT. FT. DISTANCE BET. BET.MAIN& REPAIR MOVING MAIN B1-DGS. ACCESS.BLOCS. BUILDING ) /I��// ` NO.OF VAN.# DATE SIZE / /.$ ROOMS STORIES / C.V.p.# APPROVED EXTERIOR WALL I COVERING ROOF APPROVED DATE C VERING Q BUILDING AMORE f/QBE PERF/LAMED IL I t.,.�. ,.2 A-CK BE \ 9 1 do SQ.PT. i 6 9 I HEREBY ACKNOWLEDGE THAT.I NAVE READ THIS APPLICATION THE AMOUNT SHOWN UNDER VALUATION IS FOR THE O AND STATE THAT THE ABOVE.IS CORRECT AND AGREE TO CON. PURPOSE OP ESTABLISHING A PERMIT FEE ONLY. PLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING VALUATION BUILDING CONSTRUCTION. l ///1', � / '1_ /p ) - ;I PERMIT FEE $ tJ y PERMIITTEr OF 'V 6 /�K+�Cp/ fT` O Y� PLAN CHECK S w° AUTHORIZED AGENT AL.. _ ... - . TOTAL PEE ••••••L• antra, Jnui#Itr1 Lemic• `1-19 OO JOB ADDRESS 3120 Taft Way BUILDING PERMIT NO. 26161 GENERAL CONTRACTOR Air._Vent Ainairzg DESCRIPTION OF WORK 4rnshnAe (•over Al' No. LOT p TRACT 5004 FIRE ZONE VALUE $ 280.00 SPECTIONS Signature Date GROUP I TYPE N ZONE R-1 1 Soil SUBCONTRACTOR I PERMITS ISSUED Gas Date I Number I Signature Water Plumbing Rough Plumbing sProp. Swr. Line ❑ House Con. 0 prinkling System Miscellaneous Rough Heating and Air Conditioning Temporary Service or Pole Underground 0 Power 0 _ Rough Wiring Heating and Vent. Trenches 0 Forms 0 Steel Reinf. 0 Floor System Bond Beam 0 Steel Reinforce 0 Sheathing // / Frame and Flashing If'_YW //2, 6 i Lathing— In 0 Out 0 Plaster. Brown Coat Structural, Final Electric Heating, Vent., Refrig. and A.C., Final Plumbing, Final and Gas Test 0 Electric, Final Building, Final r--''!M //k3 • ONE —FAMILY DW E L L S NG E L E CT R I CA L LOAD ' CALCilLATI ON COMPUTED LOAD [ SEE SECTION 220-10(A) ] : j45(7 sq. ft. x 3 volt-amperes per sq. ft . = t/ c/ 5'Qvolt-amperes [ ** ] MINIMUM SIZE FEEDER REQUIRED [see Section 220-10(a) ] : General Lighting (** J i/950 volt-amperes • Small Appliance Load - 3©p0 volt-amperes Laundry (Washer) • 150_0_ volt-amperes Laundry (Dryer) 1500 volt-amperes Total GeneralAppliance Light & Small Appliu:,ce . . [' ] 1O.950 volt-amperes 3003 volt-amperes at 100% [ a ] 2030 volt-ampere: [ * 11C) 950 - 2000 = 7,950 volt-amperes at. 35'-. = [b ] volt-amperes Net General Lighting & Small Appliance Lcad ( a+b ) 572. - volt- amperes F.anue Lead ( see Table 22r-1 ) [ c ] 2/0°0_ volt-am eros Dryer Lead ( see Table 220-18 ' [ d] 3/soo volt-a.-,.pere_ rO Air Conditioning Load at 103% duty [ e ] - volt-amperes [ Fixed in place appliances ) Garbage Disposal If ] Too volt-amperes NO Trash compactor • [ f ] volt-ampere: NO Microwave Oven ( f ) volt-amperes F.A.U. Motor [ f ] v-74./6 volt-amperes Garage Door Opener Motor ¶ f ] 7 /6 volt-amperes [ f ] volt-amperes ` f ) volt-amperes Subtotal fixed appliances . [ f] = 3C1 &? volt-amperes Total [ a+b+c+d+e+f ] = ,g ] g017y1 volt-amperes Demand factor of 75% to the nameplate-rating lead of four or more appliances fastened in place served by the same feeder in a one-family, two-family, or multifamily dwelling . ( see Section 220-17 ) Total appliance load [ f ] volt-amperes x 75% = [h] •. volt-amperes Total Load ( a+b+c+d+e+f] = [ i ] .2C)/ 7/9 volt-amperes or Total Load ( a+b+c+d+e+h] = [j ] volt-amperes For 120/240-volt 3-wire single-phase service or feeder , total .,load [ i ] or [ i ] here volt-amperes divided by 240 volts = (36.4/ anperres Note : Net computed load exceeds 10 kVA. Service conductors shall be 100 amperes or greater per total load. [see Section 230-42 (b) ( 2 ) ] _- YO—yo 26 vet?S / -*Lii (-to(Ity [ caiTo? fie. 7 -� sL/