Loading...
HomeMy WebLinkAbout13701 OLYMPIC AVE - Building Permits • CITY OF COSTA MESA 0 BUILDING DIVISION , DEVELOPMENT SERVICES DEPARTMENT PERMIT NUMBER rtimpina 4. C* . PERMIT B05-01382 stkbeivRatio 4fr (714)754-5273 • Fax(714)754-4856 • www.ci.costa-mesa.41LNLDING PERMIT 77 FAIR DRIVE,COSTA MESA,CA 92626 • Job Address: 13701 OLYMPIC AV Status: ISSUED Suite: Applied: 08/17/2005 Vicinity: BEDROOM AND FAMILY ROOM Issued: 08/17/2005 Primary Occ: R-3 Dwellings/Cong Res<10 Type of Construction: V-N Parcel Number: 14152127 Zoning: Applicant: GORINA, JENNIFER adOr Address: 10395 SLUSHER DR Phone: 800-807-9889 ISSUED BY: A • a SANTA FE SPRINGS,CA Zip: 90670 .07,007 ••••• '' • •.` Owner EDWARDS, CLEO, . Address 13701 OLYMPIC AVE ; -;-• .„-;r:r•-i,'` • COSTA MESA,CA IAZiP: wry% ' 1,,,,,jf""i • . r t•-•• • •,;:• •r,„:2, • „ Is D Contractor: SEARS HOME IMPROVEMENT INC if jitt Address: 10.395 il:USHERCR.. • t' DATE / s - Phone: 800-807-9889, • , - SANTA FE SPRINGS CA ' II••• • 90670. License: 721379 Arch : Eng: Address •-p -: i Address: •`' Phone: , Phone: -1•I'r LI:- I •II\ • Zip: • License: ' • , . License.:0,",-,:t;:t • SCOPE OF PERMIT. CHANGE-OUT OF 3 WINDOW(LIKE-FOR-LIKE)IN AN EXISTING SFD(2 IN BEDROOM AND 1 IN FAMILY ROOM) NO OTHER WORK AUTHORIZED WITH THIS PERMIT. • • _ . , -CI I • • .42, IP •••11 ••.17 . ftt• • I: FEE SUMMARY Plan Check: g $0:00.• • — • • • Calc Valuation: :-$1,800.00 Permit: 7.; -$63,15 '-"` ClaimValUatioh: nef -• $1800.00 shilil?;tRes: $0.5r>„, " , OAIP'Corn:, $0.00 Other. ":" -4- - 7,C2' • •,a' vt,1 Other:, ‘15.00Inspection: • • ',<•• ?ittod cs„ s us- ls• 4 Total:.ei; $63.65 PLANNING &ZONING . SETBACKS MAIN STRUCTURE Front 0-0 ti - Rear 0-0. Left 0-0 •••7:Rightr,-•-•-0-0 , _ • ACCESSORY • Front' 020 • •III•IrRear:oE0-0 tc. Left , 2,• Right : 0-0 PARKING Required: 0 , „„:•,._ • ,•• PrSposeCi: 0 t, ' .1-;4•c. , ,orir v 44, 'ea NOTICE: The work authorized by this permit shall comply with all applicable handicap access requirements under California statutes and related regulations.(Ord. No.92-28,§1, 12-21-92) EXPIRATION: This permit shall automatically expire and become void if work is not commenced within 180 days,or if work is suspended or abandoned for a period of 180 days. INSPECTIONS: In order for the work authorized under this permit to be considered legal, such work must comply with all applicable codes, and all required Inspections and final approval must be obtained.Failure to obtain inspections and final approval will result in the expiration of this permit. FOR INSPECTIONS CALL: (714)754-5626 2446-46(WOO) DECLARATIONS' -1-) C J WORKERS'COMPENSATION DECLARATION: I hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self-Insure for workers'compensation,as provided for by section 3700 of the Labor Code,for the performance of the work for which this permit is Issued. —xi have and will maintain workers'compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work for which this permit is Issued. My workers'corn ensa/tion Insurance carrier and policy number are: Q /// ---) !�/ C9mee iCLd ,'2 J // Policy 13 mberL)L tC' W 2 / (J/ a (This-section need not be completed d the e t is valued et one hundred dollars($100)or less.) - ❑ I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California,aid agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with these pr ions. Applicant Slgnatdre: L / /7!n ,Dale:—. �/ 1/i)5 E1-. WARNING:FAILURE TO SECU IVJORKERS'COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SUBJECTFOR AN EMPLOYER TO CRIMINAL P TE AND FINES UP TO ONE HUNDRED THOUSAND DOLIARE WOO, IN ADDMON TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN SECTION 37060F THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES. LICENSED CONTRACTORS DECLARATION: I hereby affirm that I am licensed under•rovisions o Chapter 9(commencing with Section 7000)of Division 3 of the Business d Professions Code,and my license is in full force and effect.at _ _ Classit C'o fs;Slgnflture:m-• s—� i tOate:. CONSTRUCTION LENDING AGENCY: ❑ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued.(Sec.3097,Civil Code). Lender's Name: Lender's Address: Signature: Date: OWNER-BUILDER DECLARATIONS: I hereby affirm'tfiat under penalty of perjury that I am EXEMPT FROM THE CONTRACTORS LICENSE LAW for the following reason(Sec.7031.5,Business and Professions Code:Any city or-county which,requires a permit to construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for such permit to file a signed statement thathe or she Is licensed pursuant to the provisions of the Contractors License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or that he or she is exempt therefrom and the basis for the alleged exemption.Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars($500).): ❑ I,as owner of the property,or my employees with wages as their sole compensation,WILL DO THE WORK,and the structure is not intended or offered for sale(Sec. 7044,Business and Professions Code:The Contractors License Law does not apply to an owner of property who builds or improves thereon,and who does such work himself or herself or through his or her own employees,provided that such improvements are not intended or offered for sale,If,however,the building or improvement is sold within one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for purpose of sale.). ' ❑ I,as owner of the property,am EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS to construct the project(Sec.7044,Business and Professions Code:The contractors License Law does not apply to an owner of property who builds or Improves thereon,and who contracts for such project with a contractor(s) license pursuant to the Contractors License Laws.). ❑ I am exempt under sec. Business and Professions Code for this reason: Signature: Date: Owner ID verified by driver's license. Yes 0 No Driver's License No. Expires: Verification of Ownership by(type of d men, .e.-property tax bill or deed): DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION: ❑ I hereby certify that no excavation five(5)or more feet in depth into which a person is required to descend,will be made in connection with work authorized by this permit,and that no building structure,scaffolding,falsework,or demolition or dismantling thereof,will be more than thirty-six(36)feet high.(Chap.3.2,Grp 2,Art 2,Sec. 341,Title 8,California Administrative Code). ❑ As owner-builder, I will not employ anyone to do work which would require a permit from the Division of Industrial Safety,as noted above, unless such person has a permit to do such work from the division. Signature: Date: - Division of Industrial Safety Permit Number: HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION: p 1 Will the applicant or present or future building occupant need to file and certify a Business Plan for emergency response to release or threatened release of a hazardous material? 0 Yes 0 No (Section 25505 of the California Health and Safety Code requires,with some exceptions,that a Business Plan be filed with the Costa Mesa Fire Department by every business which has at any one time during a reported year a quantity of hazardous materials equal to or greater than a weight of 500 pounds,or a volume of 55 gallons, or 200 cubic feet of compressed gas at standard temperature and pressure). 2 Does or will the applicant or present or future building occupant need to file a registration form for acutely hazardous materials? 0 Yes 0 No (Section 25533 of the California Health and Safety Code,with some exceptions,requires registration with the Costa Mesa Fire Department by each business which at any one time has on hand a quantity of acutely hazardous materials equal to or greeter than a weight of 500 pounds, or a volume of 55 gallons, or 200 cubic feet of compressed gas at standard temperature and pressure). 3 Does or will the applicant or present or future building occupant need to prepare an RMPP(Risk Management and Prevention Program for acutely hazardous materials)? ❑Yes ❑No (Section 25534 of the California Health and Safety Code provides that the Costa Mesa Fire Department may require the preparation,certification and filing with the Fire Department of an RMPP by businesses which are required to register acutely hazardous materials with the Fire Department. 4 If an RMPP is presently required,has Section 25534 of the California Health and Safety Code been fully complied with? 0 Yes 0 No 5 Does or will the applicant or present or future building occupant Tajjaiaraj for the work which is the subject of this application akermit for such construction or modification from the South Coast Air Quality Management District or from any other air pollution control district or agency? 0 Yes 0 No (Section 65850.2 of the California Government Code requires that the requested information be furnished on applications for non-residential building permits). 6 Will any part of the facility to be constructed under this permit be within 1000 feet from the outer boundaries of a school? 0 Yes 0 No (If yes",the facility must meet the requirement of Sections 25534 and 42303 of the Califomia Health and Safety Code). 7 If a permit from the South Coast Air Quality Management District or other air pollution control district or agency is required for the work which is the subject of this application,have all of the disclosures prescribed by California Health and Safety Code Section 42303 been made? 0 Yes ❑No 8 (If yes",attach certificate of compliance from the appropriate air pollution control officer). CERTIFICATE OF COMPLIANCE:I certify that under penalty of perjury the information given above is correct.I agree to comply with all state laws and city ordinances regarding Hazardous Materials and Emissions. Signature: Date: CERTIFICATE OF COMPLIANCE AND AUTHORIZATION OF ENTRY:I certify under penalty of perjury that I have read this application and state that the information given is correct. I agree to comply with all state laws and city ordinances relating to building construction,and authorize representatives of the City of Costa Mesa to enter upon the above-described property for inspection purposes.I agree not to occupy or allow occupancy of any building authorized by this permit until final inspection. I ature Of L I Owger(s) �7/ D rA pncam r i CODE I INSPECTION TYPE PAM )NTITIALSs CODEC )NSPECTION TYPE DAM INTMAls 1616 Fixed System Final Fire Prevention 206 Final Mechanical 1266 Pool Spa Final 208 Final Plumbing 200 Final Re-Roof 210 Final Electrical 201 Final Block/Retaining Wall 212 Final Fire Prevention 202 Final,Factory Fire Place 220 Final Planning Approval 203 Final Sign 222 Final Site 204 Final Demolition 250 Final Building/Occupancy CITY OF COSTA MESA t, "N. 1 77 FAIR DR 2„ FLOOR P.O.BOX 1200 CALIFORNIA 92628-1200 kbabossmil di' DEVELOPMENT SERVICES DEPARTMENT EMERGENCY ESCAPE AND RESCUE WINDOWS . A • Openable area= 3 5.7 sq.ft. RMinimumOpenade area= 1 E 5.7 sq.ft. • E -P- Minimum < .g - N •^ --------- ------I<20"Clear(Min.) 'I I _ 3416"Cleat 6 I (For minimum 24"heghl) X 4 Finished Floor r All sleeping rooms in dwelling units below the fourth floor shall have at least one operable window or door approved for ' emergency escape or rescue.The emergency window or door shall be operable from the inside to provide a full,clear opening without the use of separate tools. Escape or rescue windows shall have a minimum net clear openable area of 5.7 square feet.The minimum net clear height dimension shall be 24 inches. The minimum net clear width dimension shall be 20 inches. When windows are provided as a means of escape or rescue, they shall have a finished sill height not more than 44 inches above the floor. The table below shows the minimum height and width of required 5.7 square foot VNDTH 20 20.5 21 21 .5 22 22.5, 23 23.5 24 24.5 25 25.5 26 26.5 27 HEIGHT 41 40 39.1 382I 37.3 36.5 35.7 34.9 34I .2 33.5 32• .6 32.2 31 .6 31 30.4 I I II I VVIDTH 27.5 28 28.5 29 29.5 30 30.5 31 31 .5 32 325 33r 335 34 34.5 ,HEIGHT 29.8 29.3_ 28.8__ 28.3 27.8 27.4 26.9_ 26.5 26.1_ 25.7_ 253 24.9 245 -24.1 23.8` a5. Dimension on the plans 30" min. -width for water closet compartment and 24"min. clearance in front of the water closet. (UBC 2904) 46. Wall coverings in showers or tubs with showers shall be cement plaster, tile or approved equal to 70"above drain. (UBC 807.1.3) 47. Net area of shower receptor shall be not less than 1,024 sq. in. of floor area, and encompass a 30" min.diameter circle. (UPC 410.4) 48. Provide one openable escape window or door meeting all of the following: an o enab e area of not less than 5.7 sq. ft., 24"min. high and 20"min. wide, and a sill height 44" max. above the floor in tOOvv\ . (UBC 310.4) 49. Show location(s)of hard-wired smoke detectors: (UBC 310.9.1) a. Centrally located in corridors (or areas)leading to sleeping areas, and inside each sleeping room. b. On ceiling of upper level in close proximity to the stairway when sleeping areas are on an upper level. c. On each floor level and in basement. d. In the adjacent room (or area) where the ceiling height exceeds that of the hallway by 24"or more. e. Battery operated smoke detector permitted in existing construction. f. Note on plan: detector shall sound an alarm audible in all sleeping areas. g. Smoke detectors shall be hard-wired and equipped with battery backup. EXITS. STAIRS AND RAILINGS 50. One exit door shall be not less than 3'-0"wide and 6'-8"high and provide 32" min. clear width. (UBC 1003.3.1.3) 51. Landings at doors shall have a length measured in direction of travel of not less than 36". (UBC 1003.3.1.7) 52. Within individual units a door may swing over landing that is notmore than 1" below the threshold or 8"max. if the door does not swing over the landing. (UBC 1003.3.1.6) 53. Occupants on floors above the second story shall have access to two separate exits. (UBC 1004.2.3.2) (EXCEPTION: occupied roof area or third floor within an individual dwelling unit less than 500 sq. ft. may have one exit.) 54. Provide section and details of interior/exterior stairway showing: a. 8" max. rise and 9" min. run; or, 7"and 11", respectively, where stair serves two units (UBC 1003.3.3.3) b. 36" min. width (UBC 1003.3.3.2) c. 6'-8" min. head room (UBC 1003.3.3.4) d. Details and notes showing framing (stringer) sizes, bracing, connections and footings e. One-hour fire-resistive construction on enclosed usable space under the stair (UBC 1003.3.3.9) 55. For winding stairs provide 6"min. tread and provide the required run at a point 12"from the narrow side of the tread. (UBC 1003.3.3.8.2) 56. Spiral stairway shall not serve as required exit for area exceeding 400 sq. ft. (UBC 1003.3.3.8.3) . 57. Provide manufacturer, model ft and ICBO ft for prefabricated spiral stair. Alternately, submit construction drawings and structural calculations for spiral stair and supporting elements. , 58. Provide spiral stairway column base connection/footing detail. 59. Provide connection details on plans for guardrails and/or handrails on open sides of balconies, decks, landings, and stairs adequate to support 20 pounds per lineal foot load applied at a right angle to the top rail. (UBC Table 16-B) 60, Handrails shall satisfy the following: (UBC 1003.3.3.6 and 509) a. Provide continuous handrail for stairways with 4 or more risers (2 or more risers where stair serves two units) b. Handrail shall be 34"-38" above the nosing of the treads c. Openings in balusters shall be less than 4" in diameter at open side(s) d. The handgrip portion of the handrail shall be 1-1/4"-2" in cross-sectional dimension with 1-1/2"clearance to wall 61. Provide 36"min. high guardrail for decks, porches, balconies and raised floors (more than 30"above grade or floor below) and open side(s) of stair landings. Openings between balusters/rails shall be less than 4"in diameter. (UBC 509) GARAGE AND CARPORT 255246 4 �. ijNIFONM BUILDING CODE - 310.4 , 310.9.1.3 •Airpss to,and egress from,buildings required to beaccessibl If any room has a furred ceiling,the prescribed ceiling height is Y .•, i6`.4.¢i, . be provided as specified in Chapter 11. required in two thirds the area thereof,but in no case shall the • height of the furred ceilingbe less than 7 feet(2134 .4.5:..1,:f`:-. Basements in dwelling units and everysleeping room below mm). • . (�e fourth storyshall have at least one operable window or door 310.6.2 Floor area. Dwelling units and congregate residences - droved for emergency escape or rescue that shall open directly nshall have at least one room that shall have not less than 120 N 1 -• publicemergency square feet(11.2 m2)of floor area.Other habitable rooms except H mto a public street, alley,yard or exit court.The emer en q 'door or window shall be operable from the inside to provide a hill, kitrhroc shall have an area of not less than 70 square feet(65 m-). 3 clear opening without the use of separate tools. Efficiency dwelling units shall comply with the requirements of • EXCEPTION:The window or door may open into an atrium corn- Section 310.7. 7 plying with Section 402 provided the window or door opens onto an 310.63 Width. Habitable rooms other than a kitchen shall not ' exit-access balcony and the dwelling unit or guest room has an exit or F exit-access doorway that does not open into the atrium. be less than 7 feet (2134 mm)in any dimension. P Escape or rescue windows shall have a minimum net clear 310.7 Efficiency Dwelling Units. An efficiency dwelling unit openable area of 5.7 square feet(0.53 m2).The minimum net clear shall conform to the requirements of the code except as herein openable height dimension shall be 24 inches (610 mm). The provided: 9 minimumnet clear openable width dimension shall be 20 inches 1. The unit shall have a living room of not less than 220 square (508 mm). When windows are provided as a means ofescpe or feet (20.4 m'-)of superficial floor area.An additional ]11Slsnuare rescue,they shall have a finished sill height not more than 44 in- feet (9.3 m'-) of superficial floor area shall be provided for each cher (1118 mm) above the floor, occupant of such unit in excess of two. I Escape and rescue windows with a finished sill height below 2. The unit shall be provided with a separate closet. the adjacent ground elevation shall have a window well. Window wells at escape or rescue windows shall comply with the follow- 3. The unit shall be provided with a kitchen sink, cooking ing: appliance and refrigeration facilities,each having a clear working space of not less than 30 inches(762 mm)in front. Light and ven- t. The clear horizontal dimensions shall allow the window to tilation conforming to this code shall be provided. he fully opened and provide a minimum accessible net clear open- 4. The unit shall beprovided with a separate bathroom contain- 36ing of 9 square feet (0.84 m2). with a minimum dimension of P inches (914 mm). ing a water closet. lavatory and bathtub or shower. 2. Window wells with a vertical depth of more than 44 inches 310.8 Shaft and Exit Enclosures. Exits shall be enclosed as (1118 mm) shall be equipped with an approved permanently af- specified in Chapter 10. fixed ladder or stairs that are accessible with the window in the Elevator shafts.vent shafts.dumbwaiter shafts. clothes chutes fully open position.The ladder or stairs shall not encroach into the and other vertical openings shall be enclosed and the enclosure le required dimensions of the window well by more than 6 inches shall be as specified in Section 711. . (152 mm). t In nonsprinklered Group R.Division 1 Occupancies,corridors Bars. grilles, grates or similar devices may be installed on serving an occupant load of 10 or more shall be separated from -in . emergency escape or rescue windows, doors or window wells, corridors and other areas on adjacent floors by not less than ap- AHE: provided: . proved fixed wired glass set in steel frames or by 20-minute 111 1. The devices are equipped with approved release mecha- smoke- and draft-control assemblies, which are automatic clos- nisms that are openable from the inside without the use of a key or ing by smoke detection. t' special knowledge or effon:and 310.9 Smoke Detectors and Sprinkler Systems. 2. The building is equipped with smoke detectors installed in 0 accordance with Section 310.9. 310.9.1 Smoke detectors. QO111. 310.931 General. Dwelling units, congregate residences and i • 310.5 Light,Ventilation and Sanitation. Light and ventilation hotel or lodging houseest rooms that are used for sleeping pur- shall be as specified in Chapter 12.The number of plumbing fix- poses shall be provided with smoke detectors.Detectors shall be tures shall not be less than specified in Section 2902.6. installed in accordance with the approved manufacturer's instruc- :: a 310.6 Room Dimensions. tions. 310.6.1 Ceiling heights. Habitable space shall have a ceiling 310.9.1.2 Additions,alterations or repairs to Group R Occu- ir height of not less than 7 feet 6 inches(2286 mm)except as other- pancies. When the valuation of an addition,alteration or repair . wise permitted in this section.Kitchens.halls.bathrooms and toi- to a Group R Occupancy exceeds 51.000 and a permit is-required, let compartments may have a ceiling height of not less than 7 feet or when one or more sleeping rooms are added of created in exist- a (2134 mm) measured to the lowest projection from the ceiling. ing Group R Occupancies,smoke detectors shall be installed in Where exposed beam ceiling members are spaced at less than accordance with Sections 310.9.1.3, 310.9.1.4 and 310.9.1.5 of 48 inches(1219 mm)on center,ceiling height shall be measured this section. to the bottom of these members. Where exposed beam ceiling EXCEPTION: Repairs in the exterior surfaces of a Group R Occu- members are spaced at 48 inches(1219 mm)or more on center, panty are exempt Gom the requirements of this section. . ceiling height shall be measured to the bottom of the deck sup- 310.9.13 Power source. In new construction, required smoke ABU ported by these members,provided that the bottom of the mem- detectors shall receive their primary power from the building wir- bers is not less than 7 feet(2134 mm)above the floor. ing when such wiring is served from a commercial source and .• If any room in a building has a sloping ceiling,the prescribed shall be equipped with a battery backup.The detector shall emit a • ceiling height for the room is required in only one half the area signal when the batteries are low.Wiring shall be permanent and thereof. No portion of the room measuring less than 5 feet(1524 without a disconnecting switch other than those required for over- mm) from the finished floor to the finished ceiling shall be in- current protection.Smoke detectors may be solely battery oper- .. . eluded in any computation of the minimum area thereof. ated when installed in existing buildings;or in buildings without