HomeMy WebLinkAbout416 ENCLAVE CIR - Building PermitsCITY OF COSTA MESA ' . BI/ILDING DIVISION F � 77 FAIR DRIVE, COSTA MESA, CA 92626 •(714) 754-5273 • Fax (714) 754•4856 • w�vw.ci.wsta-mesa.ca.us �, FOR INSPECTIONS CALL: (714) 754-5626 ��,. F07-00212 FIRE SUPRESSION PERMIT Job Address: 416 ENCLAVE CI - � — � • � � � Suite: -, �, � - Viciniry: - . --, . ' ' ' Parce�Nunmbec TPN007040''-',--`. � - ,Zoning: . , App�icane DOUG BROZOVICH- :, � � Address: 1202 EAST HUNTER AVE� . � ' � � - Phone: 714-237-0739 � SANTA ANA, CA - � Zip: 92705 ' . Owner THE IRVINE COMPANY' Address 110 INNOVATION I � � � � � � ' � � � Phone: 949-720-5536 IRVINE.CA . ..,... .Zip: 92612. . . . ` . , Contrecror BAKER COMPANY CONSTRUCTORS INC Address: 1202 EAST HUNTER AVE , � �- . ' , � , � Phone: �714-835-8572 SANTA ANA; CA;, �-' Zip: 92705'� _' ' , License: 822444 � SCOPE OF'PERMIT PHASE 3, INSTALL 240 OVERHEAD SPRINK4.ERS FOR NEW 17;030 "ENCLAVE�APARTMENT HOMES" ._ � � , , " � � :,�, . ; � =; " FEE SUMMARY $0.00 ,. .., _. ,, 50.00 $0.00 Plan Check: Permit: Other: Total: $0.00 Status: ISSUED Applied: O6/27/2007 Issued: 07IO2I2007 , �, i, S.F.,MFD, TYPE 1A, 20 UNITS, Calc Valuation: So.00 ' Claimed Valuation: so.00 FFP-cw- bl��lo$ NOTICE: The work authorized by this permit shall comply with all applicable handicap access requirements under Califomia statutes and related regulatlons. (Ord. No. 92-28, § 1, 12-21-92) EXPIRATION: PERMIT EXPIRES 780 DAYS FROM DATE OF ISSUE OR DATE OF LAST INSPECTION. INSPECTIONS: In order for the work authorized under this permil to be considered legal, such work must comply with all applicable codes, and all required inspections and final approval must be obtained. Failure to obtain inspections and fnal approval will result in the expiration of this permit. CQUE/. INSPECTIONTYPE ORT� IN71ML5 �e INSPECTONTYVE 04T IN L 7816 Fixed System Final Fire Prevention 206 Final Mechanical 1266 Pool Spa Final � 208 Final Plumbing 200 Final Re-Roof 210 Final Electncal 201 Final Blotk/Retaining Wall 212 Final Fire Preven�i0n "� QGY 202 Final Factory Fire Place 220 Final Planning Appraval 203 Final Sign 222 Final Site 204 Final Demolition ZC�O Final Building�Occupancy WORKERS' COMPENSATION DECLARATION: I hereby aKrm untler penalty of perjury one of the�tu��.,wing declarations: ❑ I have and will maintain a ceAi(cate of consent to sel(-Insure (or workers' Compensalion, a5 provided for by seCtion 3700 of (he Labor Code, for the peRormance o( the work for which Ihis permit is issued. ��I'have and will main[ain v.orkers' compensation insurance, as required by ctbn-3700 of the Labor Code, for the performance of ihe work for which this pertnit is issued. My vrorkers' pompensation Insurance carrier and policy ❑ I certify that in the pertormance of [he work for which this permit is issued, I shall not employ any person in any manner so as to become subjecl ro the workers' compensation laws o( Califomia, and agree that if I should become subject to the vrorkers' compensation provisions of Section 3700 of the La6 F ia forth 'tq-c mply with these provisi s �ApP���nPSSiqnawre � L Da�e ��.� WARNING FAIL O SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, IMEREST, AND ATfORNEY'S FEES. LICENSED CONTRACTORS DECLARATION: I hereby affirm thal I am licensed under provisions of Chapter 9(commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license js.j �tull foSce �n� eftect. n I 1 CONSTRUCTION LENDING AGENCY: ❑ I hereby aKrm that there is a construction lending agency for the peAortnance of the work fa which this pertni� is issuetl. (Sec. 3097, Civil Cotle). Lender's Name: Lender's Address: SignaWre �ale OWNER-BUILDER DECLARATIONS: I hereby aKrm lhat under penally of perjury thal I am EXEMPT FROM THE CONTRAC70RS LICENSE LAW for the following reason (Sec. 7031.5, Business and Professions Code: Any city or counry which requires a permit to construct, alter, improve, tlemolish, or repair any shucNre, prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Comractors License Law (Chapter 9(commencing with Section 7000) of Division 3 of Ihe Business and Professions Code) or that he or she is exempt iherefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than fve hundred dollars ($500).): ❑ I, as owner of the property, or my employees with vuages as their sole compensation, WILL DO THE WORK, and lhe structure is not intended or otfered for sale (Sec. 7044, Business and Professions Cotle: The Contracmrs License Law does not apply to an owner of property who builds or improves thereon, and who tloes such vrork himself or herself or [hrough his or her ovm employees, provided Ihat such improvements are not intendetl or oRered for sale. If, however, the building or improvement is sold within one year of completion, the ovmer-builder will have the burden of proving.that he or she did not build or improve for purpose of sale.). ❑ I, as o,wner of the property, am EXCLUSIVEIY CONTRACTING WITH. LICENSED CONTRACTORS to construct the pmject (Sec. 7044, Business and Pm/essions Code: The contraclas License Law dces not apply to an ovmer o( property who builds or improves thereon, antl who contracts for such project with a contractor(s) license pursuant to Ihe Contractors License Laws.). ❑ I am exempt�under sec. Business and Pmfessions Cotle for this reason: Ovmer ID venfied by driv� nse. ❑ Yes ❑ No Driver's License No. Expires: Verifca�ion o( Ownership by (rype of dowment, i.e. - property tax bill or deed): �DIVISION OF INDUSTRIAL SAFEN PERMIT CERTIFICATION: � I hereby ceAify that no excavation (ne (5) or more feet in depth into which a person is required to descend, will be made in connection with work authonzed by this permit, antl lhat no building structure, scaffdding, (alsework, a tlemolition or dismantling ihereof, will be more ihan thirty-six (36) (eet high. (Chap. 32, Grp 2, Ari 2, Sec. 341, TiUe 8, Califomia Administrative Cotle). ❑ As owner-builtler, I will not employ anyone to do work which would require a permit from the Division of Industrial Safety, as noted above, unless such person has a permit to do such vrork from the tlivision. Applicanfs $ignaWre Division of Industrial Safety Permit Number _ HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION: 1. Will the appliwnt or present or future building occupant neetl to fle and certify a Business Plan for emergency response to release or Ihreatened release of a hazardous material? ❑ Yes ❑ No (Section 25505 of the California Health and Satety Code requires, with some exceptions, that a Business Plan be filetl with the Costa Mesa Fire Department by every business which has at any one time during a reported year a quantity of hazardous matenals equal to or greater than a weight of 500 pounds, or a volume of 55 gallons, or 200 cubic feet of compressed gas at standard temperaWre and pressure). 2. Does or will the applicanl or present or (uNre building occupant need [o fle a regis[ralion form for acutety hazardous materials? ❑ Yes ❑ No (Section 25533 of the Califomia Health antl Safety Code, with some exceptions, requires registretion with the Costa Mesa Fire Department by each business which at any one time has on hand a quantiry o( acutely hazardous materials equal to or greater than a weight of 500 pountls, or a volume o( 55 gallons, or 200 cubic feet of compressed gas al standard temperaWre and pressure). 3. Does or will the applicant or present or (uture building occupam need to prepare an RMPP (Risk Management and Prevention Program for acutely hazardous materials)? ❑ Yes ❑ No (Sec�ion 25534 of �he Califomia Health antl Sa(ety Code pmvitles Ihat the Costa Mesa Fire Department may require the preparation, certifcation and filing wi[h the Fire Oepanment of an RMPP by businesses which are required to register acutely hazardous materials wi[h [he Fire Department. 4. If an RMPP is presently required, has Section 25534 of lhe Cali(omia Health and Safety Code been fully complietl with? ❑ Yes ❑ No 5. Does or will the applicant or present or fWure builtling ocwpant require for the vrork which is the subject of this applica[ion a permit for such construction Or motlificalion from lhe Soulh Coast Air Quality Management Districl or from any oiher air pollution control distnct or agency? ❑ Yes ❑ No (Sectbn 658502 0( the Califomia Govemment Code requires that the requested infortnation be fumished on applications for nomresitlential building pertnits). 6. Will any part of the (aciliry to be constructed under this permit be within 1000 feet from the outer boundanes of a school? ❑ Ves ❑ No Qf'yes", �he facility must meet the requirement of Sections 25534 and 42303 of the Califomia Health and Safety Code). 7. If a permit from the South Coast Air Quality Management Dislnc[ or ol�er air polWtion control distric[ or agency is required for Ihe work which is the subject of this application, have all of the disclosures prescribed by Califomia Health antl Safety Code Section 42303 been made? ❑ Yes ❑ No. B. Qf "yes", attach certifwte of compliance from the appropriate air polWtion control oKcer�. . CERTIFICA7E OF COMPLIANCE: I certify that under penalry of perjury the �information given above is correct I agree to comply with all state laws and city ordinances regarding Hazardous Materials and Emissions. � Signature Date CERTIFICATE OF COMPLIANCE AND AUTHORIZATION OF ENTRY: I certi(y under penalty of perjury that I have read this application and state thal the information given is correcL I agree to comply with all state laws and city ordinances relating to building construction, and authorize representatives of the City of Costa Mesa to enter upon the above-described property (or inspeclion purposes. I agree not to occupy or allow occupancy of any building authorized by this permit unlil fnal inspection. ' iglidl e o ega mer �aqte �,,��/ SignaWre �a�e �_� �� L, � � 305]-0fi (3/Ol) � ��..,(� �Ana/or A'ul�oriiaG Applicant,,,�,_,_,� �--�- Daia��v�--�1 r,y„ ... CITY OF COSTA MESA o "'F, BUILDING D/VISION F`�� 77 FAIR DRIVE. COSTA MESA. CA 92626 •(714) 754-5273 • Fax (714) 754-0856 • �wvw.ci.costa-mesa.ca.us ��oFOR INSPECTIONS CALL: {714) 754-5626 F07-00212 '� FIRE SUPRESSION PERMIT JobAddress: 416 ENCLAVE CI Suife: Vicinity: Parcel Nunmber: TPN007040 Applicant: KIRK HEMANS Address: Owner: THE IRVINE COMPANY Adtlress 1101NNOVATION IRVINE, CA Zoning: Phone: 714-666-8450 Zip: Phone: 949-720-5536 Zip: 92612 Contr�qor: RESIDENTIAL FIRE SYSTEMS INC Address: 2871 E VIA MATRENS ANAHEIM, CA Phone: 714-666-8450 Zip: 92806 License: 786965 Stalus: ISSUED Applied: 0627l2007 Issued: 07/02/2007 SCOPE OF PERMIT PHASE 3, INSTALL 240 OVERHEAD SPRINKLERS FOR NEW 17,030 S.F. MFD, NPE 7A, 20 UNITS, "ENCLAVE APARTMENT HOMES" FEE SUMMARY Plan Check: $0.00 Permit: 50.00 Other: $0.00 Tatal: $0.00 �' «' C w- �o � 1'1 � �� Calc Valuation: so.00 Claimed Valuation: so.00 NOTICE: The work authorized by this pertnit shall comply with all applicable handicap access requirements under California statutes and related regulations. (Ord. No. 92-28, § 7, 72-21-92) EXPIRATION: PERMIT EXPIRES 180 DAYS FROM DATE OF ISSUE OR DATE OF LAST INSPECTION. INSPECTIONS: In order for lhe work authorized under this permit lo be considered legal, such work musl comply with all applicable codes, and all required inspections and final approval must be obtained. Failure to obtain inspections and fnal approval will result in the expiration of this permit. L� INSiECTIOMTYPE QRjF� NTI AL CODEI INSPECTIONTVVE D� N iUL 1616 fixed System Final Fire Prevention 206 Final Mechanical 1266 Pool Spa Final 20B Finai Plumbing 200 final Re-Roof 2t0 Final Electrical 201 Final Block/Retaining Wall 2t2 Final Fire Prevention �'� 7�� '�'�'-'' 202 Final Factory Fire Place 220 Final Planning Approval 203 FinalSign 222 FinalSite 204 Final Demolition ' 250 Final BuildinglOccupancy WORKERS' COMPENSATION DECLARATION: I hereby aKrm under penal�y of perjury one of Ihe tollowing declarations: ❑ I have antl will mainUin a certificate o( consent to sel(-Insure (or workers' compensalion, as provitletl for by section 3700 of the Labor Code. for the pertormance Of the wOrk for which this pertnit is issued. +' -`Phave and will maintain eorkers' compensatbn insurance, as required by ".e - io`n 3700 of the Labor Code, for the perfortnance of ine work for which this pertnit is issuetl. My workers' wmpensation Insurance carrier and policy �Cmber, are: � arrier.�'`��"T�'�%� �N� (inisscaibnnaednoteecanp/N ��tn,e-p�emm�7svadxdarwren�mdretlddarsfSta0lpbssJ Polit�y�'Num_`,ber;� .'Y'.-1 �Yi / -�Y� �� 7P�� � ❑ I certify that in the peAormance of the work for which this permit is issued, I shall not employ any person in any manner so as to bewme subject lo the workers' wmpensation laws of Califomia, and agree thal if I should become subject lo the workers' compensation provisions o( Sectio 3700 0l the Labor Code. I 1(forthwith comply with Nese provision . � ^—_ b�i,,. � r Wl'e`:4' �.MWieu�'s���ure.'_.--• • �/:u.voa „__^e�. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SU&IECT AN EMPIOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE CAST OF CAMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, IMEREST, AND ATTORNEY'S FEES. LICENSED CONTRACTORS DECLARATION: I hareby affrtn that I am licensed under provisions of Chapter 9(commencing with Section 7000) of Division 3 0( the Business and Professions Code, and my license_is in full force and eHect. CONSTRUCTION LENDING AGENCY: ❑ I hereby affmm that there is a consimcl'an lentling agency for the peAortnance of the v.ork fa �Mich tNs pertnit is issued. (Sec. 3097, Civil Code). Lentler's Name: Lentler's Address: OW NER-BUILDER DECLARATIONS: I hereby affirm Ihat under penalry ol perjury that I am EXEMPT FROM THE CON7RACTORS LICENSE LAW tor the following reason (Sec. 703t.5, BUsiness and Profe55ions COtle: Any ciry or wunry which requires a partnit to consWct, alter, improve, tlemalish, or repair any strucNre, prior to ils issuanca, also requires Ne applicant for such pertnit to file a signed statement Ihal he or she is licensed pursuant to the provisions of the Contractors License Law (Chapter 9(commencing with Section 7000) of Division 3 of the Business and Professions Code) or ihat he or she is exempt therefrom antl the basis lor Ihe alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects lhe aDPliwnt ro a civil penalty o( no[ more than fve huntlred dollars (5500).): ❑ I, as owner ol the property, or my employees with vrages as I�eir sole compensation, WILL DO THE WORK, antl the structure is not intended or offered lor sale (Sec. 7044, Business and Professions Code: The Contractore License Law Oces not apply to an owner o( property who builds or impmves thereon. and who dces such vrork himsel( or �erself or throu9h his or her own employees, provided ihat such improvemenls are not intended or oftered for sale. If, hovrever, ihe building or improvement is sold vrithin one year of wmpletion, the owner•builder will have the burden of proving that he or she did not build or improve for purpose of sale.). ❑ I, as owner of the property, am EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS to croslrucl Ihe project (SecJ044, Business antl Professbns Code: The contrectors License Law tices not appty to an ovmer of property who builtls or improves tliereon, and who cont2cls (or suth project with a cmtracta(s) ticense pursuant to the Contractors License Laws.). ❑ I am exempt under sec. Business and Professions Code for this reason: $ignaWre ' Da�e 309�46 (3/0)) Owner ID venfieC by Oriver's li. .a. ❑ Yes ❑ No Driver's License No. Expires: Venficalion of Ownership by (rype of document, i.e. - property �ax bill or deetl): DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION: ❑ I hereby certily that no excavation frve (5) w more feet m deplh into wAich a persm is required to tlescentl, v.ill be made in connection vrith work autlarized by Ihis permit, antl that rro buildifg struclure, scaF(dding, false�wrk, a Cemditbn or tlismantling lhereof, will be more than thirty-siz (36) (eet high. (Chap. 32, Grp 2, M 2, Set. 341, Title 8, Cali(wnia Administ2tive Code). ❑ As ovmer-builder. I will no� employ anyone to do work which would require a permit from lhe Division ol Industrial Sa(ety, as noteA above, unless such person has a permil to do such wark from lhe tlivision. AppliWnYS SipnaWrc Wte Division of Industrial Safety Permil Number: _ HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION: 1. Will the applicant or present or luture building occupant neetl to file and certify a Business Plan for emergency response to release or threatened release o( a hazartlous matenall ❑ Yes ❑ No (Section 25505 0( the Cali(omia Health and Salety Coda requires, with some exceptions, that a Business Plan be filetl with Ihe Costa Mesa Fire Depanment by every business which has at any one time dunng a reported year a quanlity of hazardous materials equal to or greater t�an a weight of 500 pountls, or a volume of 55 qallons, or 200 cubic teet of compressetl gas at slandard temperaWre and pressure�. 2. Does or will the applicant or present or future builtling occupant need to file a registration form lor acutely hazardous materials? ❑ Yes ❑ No (Sec�ion 25533 of the Calilomia Health and Safery Code, vrith some exceptions, requires registration with the Cosla Mesa Fire Department by each business which at any one lime has on hand a quantity of acutely hazardous materials equal to or greater than a weight ol 500 pountls, or a volume of 55 gallons, or 200 cubic leel of compressed gas at standard temperature and pressure�. 3. Does or will Ihe applicant or present or luture Duiltling occupant neetl to prepare an RMPP (Risk Management antl Prevention Program for awtely hazardous matenals)? ❑ Yes ❑ No (Seclion 25534 of [he California Health and Safety Code provides that l�e Cosla Mesa Fire DepaAment may require the preparation, certification and filinq with the Fire Department of an RMPP by businesses which are required to register acutely hazardous materials with Ihe Fire Depariment. 4. If an RMPP is presently required, has Section 25534 of Ne Califomia Health antl Safety Cotle Deen lully complied vrilh7 � Yes ❑ No 5. Does or will the appliwnt or present or luture building occupant require for Ihe work which is Iha subjacl ol lhis application a pertnit (or such conSWcHon or modification from the Soulh Coast Air Ouality Management District or Imm any olher air pollulion control distncl or agency7 ❑ Ves ❑ No (Seclion 65850.2 of the Califomia Govemment Cotle repuires that the requested infama�ion be fumished on applications for non-residential builCing pertni[5�. 6. win any part ot the lacility lo be consWcted under Ihis permil be within t0001ee1 from the outer boundaries o( a schoo1l ❑ Yes ❑ No (If "yes", lhe lacility must meet the requiremenl of Seclions 25534 antl 42303 of the Calilomia Healt� and Safety CoEe). 7. I( a Dertnil Irom Ihe South Coast Air Ouality Manaqement Dis[ricl or other air pollution control district or agency is required for the work which is the subject of this applicalion, have all ol the disclosures prescribed by Califomia Health and Safety Code Section 42303 been maCe? ❑ Yes � No 8. (If'yes", attach certificate of compliance from Ihe appropriate air pollutlon coNrol oKceq. CERTIFICATE OF COMPLIANCE: I certity lhat untler penalry of perjury [he infortnation given above is correcl I agree to wmply with all state laws and city ordinances regarding Hazardous Materials and Emissions. SignaWre Da�e CERTIFICATE OF COMPLIANCE AND AUTHORIZATION OF ENTRY: I certify under penalty of perjury thal I have rea0 this application and state that ihe infortnation given is cortect. I agree to comply with all state laws and city ordinances relating to builtling wnstruction, antl authorize representatives of the Ciry of Costa Mesa to enter upon the above-described property for inspection purposes. I agree not lo occupy or allow occupancy of any buildin9 authorized by Ihis permit until final inspeclion. - , Signa� � 01 LeBal Ovmer(s) �e /c ,�•9. .n%""'�A ttAul�o�iiedA`p'pllam;:•. - �.v e• ��_ ... _ �1 �:. CITY OF COSTA MESA BYILDING DIVISION F` . � 77 FAIR DRIVE, COSTA MESA, CA 92626 •(714) 754-5273 • Fax (714) 754-0856 • www.ci.costa-mesa.ca.us �. FOR INSPECTIONS CALL: (714) 754-5626 F07-00311 �'"'°'°"°� FIRE SUPRESSION PERMIT JobAddress: 4�6 ENCLAVECI ` � . - � - .-. � . . _ � Staws: ISSUED Suite: . � . .. ... ' Applied: 10/31/2007 Vicinity: � - � - . � Issued: 11/OB/2007 Parce� Nunmber TPN007040, '.,' - __ Zoning: � /r.-:�. �'� �' . - � � � � , . Applicant: VICTOR+BACANCIO :' �:, Address: 17992 COWAN - ' Phone: 949-474-0555 �. - � • IRVINE;^�CA ��� _ - Zip: 92614 � - � " � � i . .�'., . � ._ . � . owner THE IRVINE COMPANY. Address 1101NNOVATION ,� � � �� � ��� ", " . � - . ' � Phone: 949-720-5536 � � �� � IRVINE, CA � , . Zip: 92612 � � ' � - Contracror: THE GREATER ALARM CO INC Address: 17992 COWAN . - � - � . , Phone: 949-474-0555 .. .. ' � IRVINE,�CA �� , : Zip: 92614 � - ' , .. . �, ,,, , �� � ' License: 469046 �� SCOPE OF PERMIT FIRE ALARM SYSTEM FOR PHASE III: NEW� 17,030 S.F. MFD, TYPE tA, 20 UNITS W/3,233 S.F. ATTACHED GARAGES FOR "ENCLAVE APARTMENT HOMES". REF#: BC07-00054 FEE SUMMARY Plan Check: $0.00 , Calc Valuation: So.00 Permit: � _ Claimed Valuation: $o.00 Othec $0.00 Total: «1�'CW - � I 1� 10� NOTICE: The work authorized by this permit shall comply with all applicable handicap access requirements under Califomia statutes and related regulations. (Ord. No. 92-28, § 1, 12-21-92) � EXPIRATION: PERMIT EXPIRES 180 DAYS FROM DATE OF ISSUE OR DATE OF LAST INSPECTION. INSPECTIONS: In order for the work authorized under this permit to be considered legal, such work must comply with all applicable codes, and all required inspections and final approval must be obtained. FaiWre to obtain inspections and fnal approval will result in the expiration of this permit. OE . INSPECl10NTYPE DRTE INTI71AL5 LOOE;1 'INSPECTIONTYPE DRTE INTITIpL 1616 � Fized System Final Fire Prevention 206 Final Mechinical 1266 Pool Spa Final ' ' 208 Final Plumbing 200 Final Re-Roof 210 Final Electncal 201 Final Block/Retaining Wall � 212 Final Fire Prevention � -•� .", � 202 Final Factory Fire Place 220 Final Planning Appmval 203 Final Sign 222 Final Site 204 Final Demolition ' 250 Final Building/Occupancy WORKERS' COMPENSATION DECLARATION: I hereby aKrtn untler penalry of perjury one of the following declarations: ❑ I have and will mainlain a certificate of wnsent to self-Insure for workers' compensation, as provided for by seclion 3700 of the Labor Code. for the perfoimance of the work for which this permit is issuetl. I have and vnll maintain wo`kers' compensation insurance, as requiretl by s tbn 3700 of lhe Labor Code, for the pedormance of the work foi which this pertnit is issued. My vrorkers' compensation Insurance carrier and policy number are: ' '/ Cartier:- � ����J T �T�� � N�, • � (7Ais se[Abn neetl rrof mmdetetl il e permd is valued at one ho1ntlietl tldlars (5/00) orless ) Policy Number: r� d� �O,'% / ❑ I certiFy Ihat in [he pertortnance of the vrork for which Ihis permit is issued, I shall not employ any person in any manner so as to become subject to the workers' co pe sation laws o( California, antl agree that if I should become subject ,[he rkers' compensation provisions of Section 3700 of the Labor Code e�( orthvnth comply with lhese pmvisions. A = fs Signal LDate �� i WARNING: FAILU O SEC WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHAIL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOILARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEV'S FEES. LICENSED CONTRACTORS DECLARATION: I hereby aKrm that I am licensed under provisions of Chapter 9(commencing with Section 7000) o( Division 3 of the Business antl Professions Code, and my license is in full force and eflect. ���.-�- > � �� s� c�a -�► �� �_u•9•0� Conl ' 9gnaWre (�_Date_TT CONSTRUCTION LENDING AGENCY: ❑ I hereby aKrtn tha[ there is a construc[ion lentling agency for Ihe pedortnance of the v.ork fa wfiich this permit is issued. (Sec. 3097, Civil Code�. Lender's Name: Lender's Address: OWNER-BUILDER DECLARATIONS: I hereby aKrm that under penalty of perjury [hat I am EXEMPT FROM THE CONTRACTORS LICENSE LAW for the following reason (Sec. 7031.5, Business and Professions Code: Any ciry or county which requires a permit to construct, alter, improve, demolish, or repair any sirucNre, pnor ro its issuance, also requires the applican� tor such permit to fle a signed statement that he or she is licensed pursuant [o the provisions of the Contrectors License Law (Chapter 9(commencing with Section 7000) of Division 3 of the Business and Professions Code) or thal he or she is exempt therefrom and the hasis for the alleged ezemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than fve huntlretl dollars ($500).): . ❑ I, as ovmer of the property, or my employees wi[h wages as iheir sole compensation, WILL DO THE WORK, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves Ihereon, and who does such vrork himself or herself or through his or her own employees, provided that such improvements are not intended or oHered for sale. If, however, the building or imprOvement is sold within one year of completion, the owner-builder will have ihe burden of proving that he or she did not build or impmve for purpose of sale.). ❑ I, as ovmer of Ihe property, am EXCLUSIVELY CON7RACTING WITH LICENSED CONTRAC70RS to construct the projecl (Sec. 7044, Business and Pm(essions Code: The con[ractas License Law dces not appty lo an owner o( property who builds or improves thereon, and who contracts for such project vnth a contracta(s) license pursuant tothe Contractors License Laws.). � � I am exempt under sec. Business and Professions Code for this reason: Slgnature �a�e 305�-66(3/0]) Owner ID verified by driver's . .ee. ❑ Yes ❑ No Dnver's License No. Expires: Verification of Ownership by (type of document, i.e. - property tax bill or deed): DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION: ❑ I hereby cert'rfy �hat no excavation frve (5) or more feet in tlepth into which a person is required to descend, vnll be made in connection with work authonzed by this pertnit, and Ihat no building s[ructure, scaffdding, lalsework, or demolition or disman[ling thereof, will be more [han thirty-six (36) fee[ high. (Chap. 32, Grp 2, Art 2, Sec. 341, Title 8, Califomia Administrative Code). ❑ As owner-builtler, I will not employ anyone to do vrork which would require a permi[ from the Division of Indus[nal Safety, as noted above, unless such person has a permit to do such vrork from the division. ApPli[anl's Signalure Division of Indusirial Sa(ety Permi[ Number: HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION: i. Will the applicant or present or future building occupant need to file and certify a Business Plan for emergency response to release or threatened release o( a hazardous material? ❑ Yes ❑ No (Section 25505 of lhe California Heal[h and Safety Code requires, wi[h some exceptions, that a Business Plan be filed with the Costa Mesa Fire Department by every business which has at any one time during a reportetl year a quantity of hazardous matenals equal to or greater than a weight o( 500 pounds, or a volume of 55 gallons, or 200 cubic feet of compressetl gas at standard temperawre and pressure). 2. Does or will the applicant or present or future building occupant neetl to fle a registration (orm for acutely hazartlous materials? ❑ Yes ❑ No (Section 25533 of lhe Califomia Health and Sa(e[y Code, wi[h some excep[ions, requires registretion wi[h the Costa Mesa Fire Depariment by each business which at any one time has on hand a quanlity of acutely hazardous materials equal to or greater than a weight of 500 pounds, or a volume of 55 gallons, or 200 cubic feet of compressed gas at standard temperature and pressure). 3. Does or will the applicant or presen[ or fuNre building occupant need to prepare an RMPP (Risk Managemen� and Prevention Program for acutely hazardous materials)? ❑ Yes ❑ No (Section 25534 of the Cali(omia Heal[h and Safety Code provides that the Costa Mesa Fire �epartment may require the preparation, certification and filing wi[h Ihe Fire Departmen[ of an RMPP by businesses which are required to regisler acutely hazardous materials with Ihe Fire DepartmeN. 4. I! an RMPP is presently required, has Section 25534 of the California Health and Safety Code been (ully complied with? ❑ Yes ❑ No 5. Does or will the applicant or present or future builtling occupant require for lhe vrork which is lhe subjec� of [his application a permit for such constmction or modification from lhe South Coast Air Quality Management Districl or (rom any other air polWtion control disMct or agency? ❑ Ves ❑ No (Sec[bn 658502 oF the Califomia Govemment Code requires that Ihe requested infwmation be fumished on applications for non-residential building permits). 6. Will any part of the (acility to be constructed under Ihis permit be within 7000 feet from the outer boundaries of a school? ❑ Yes ❑ No Qf'yes", the faciliry must meet the requirement of Sections 25534 and 42303 ot ihe California Heallh antl Sa(ety Code). 7. If a permil from the South Coast Air Quality Management District or o[her air pollution wntrol district or agency is required for the work which is the subject of this application, have all of the discbsures prescribed by Califomia Health and Satety Cotle Section 42303 been made? ❑ Yes ❑ No 8. (If'yes", anach certificate of compliance from the appropriate air pollution control officeq. CERTIFICATE OF COMPLIANCE: I ceAify that under penalty of perjury the information given above is correcL I agree to comply with all state laws and city ordinances regarding Hazardous Materials antl Emissions. Signawre CERTIFICATE OF COMPLIANCE AND AUTHORIZATION�OF ENTRY: I certify under penalry of perjury that I have read this application and state that the in(ormation given is correct I agree ro comply with all state lavus antl ciry ordinances relating to building conslruction, and authorize representatives of me City ot Costa Mesa to enter upon the above-described pmperty tor inspec[ion purposes. I agree not to occupy or allow occupancy of any building authorizetl by this permit until final inspection. SiqnaW meqs) Dale _ _ j�,C� •D7 A�tl) u n je0 App i � ! Dale" - _ — _ � ) [ �: . , . � � .. , • � ' CITY OF COSTA MESA evao�N� o�v►s�oN � 77 FAIR DRIVE, COSTA MESA, CA 92626 •(714) 754-5273 • Fax (714) 754-4856 • vnvw.ci.costa-mesa.ca.us � � FOR INSPECTIONS CAIL: (714) 754-5626 PERMIT NUMBER: BC07-00054 a PERMIT TYPE: B COMBO STATUS: ISSUED Sub Type: MFD_NEW ,. DATE ISSUED: 06I2512007 - - ISSUED BY: SOK JOe nooReSs: 416 ENCLAVE CI CM` ; „ Suite/Unit: Viciniry: : Primary Occ ConstType: V-1H , :'., �� ''.SQ.�FT, �µ����17030 �-�� Valuetion:_1,,940,1,85.00 . SCOPE OF WORK: PHASE III: NEW 17,030 S.F. MFD, TYPE tA, 20 UNITS. W/3,233��S._F. �ATTACHED GARAGES FOR "ENCLAVE APARTMENT HOMES" � < " �� ,:a; OWNER: THE IRVWE;COMPANY !' , �- �-Address: 1101NNOVATION � Unit: , PHONE: 949-720-5536 , > ; .r � ,. , ��� . CitylStatA/Zip: IRVINE, CA . .. . APPLICANT: PEGGY BLOCK --� '- Address: 8 EXECUTIVE CIRCLE Unit: PHONE: 714-557-0244 � . - - City/State/zZip: :- ... . . . . .. ,._... _ CONTRACTOR: WESTERN NATI�ONAL CONTRACTORS _ - ,. � � Address: 8 EXECUTIVE CIRCLEUnit - . � City/State� IRVINE,CA . ZipCode: 92614 . - --� - �„ ARCHITECT: � .. � - License No. � ENGINEER: - - License No. . -. � COMBINTATION PERMIT.FEE SUMMARY -_ Buildin Plan Check - -� $1 469�55 � - IRVINE, CA � . - .. .. ' � . �.. License No: 840973 � - PHON E: 714-557-0244 .- CELL: " � � ' PHONE: � . _ � �:-PHONE: g Building Fees: ,�,��, $9;043 40 .-' ��>��., .., �� - � Electrical Fees: � . ' - ����$875.00' . - � : , Mechanical Fees: � - � �, $1,04720 _. �'.:-�� ',.- .- . . �, .�,_ . . . � .., , Plumbing Fees: ?,, $1.,91330��;��... � -- ' � SMIP Residential: � �����::$194 02 ``.... , �� r'��' � . ' � SMIP Commercial: - �$0:00. . . . _ • . • TOTAL FEES: $13,072:92 : ,: _ - "Re(er [o fee receip[s for all (ees paid for project " �"- � � � � - � :' NO710E: The work au[horized by this permit shall comply vrith all applicable handicap access requirements under California statutes and related regulalions. (Ord. No. 92-28, § 1, 12-21-92) EXPIRATION: PERMIT EXPIRES 180 DAYS FROM DATE OF ISSUE OR DATE OF LAST INSPECTION. INSPECTIONS: In order for the work authorized under this permit to be wnsidered legal, such work must comply with all applirable wdes, and all required inspections and final approval must be obtained. Failure to obtain inspections and final approval will result in the ezpiration of this permil. CODE �. INSPECTION TYPE 1616 Fixed System Final Fire Prevention 1288 Pool Spa Final � � 200 Final Re-Roof 201 Final Block/Retaining Wall 202 Final Factory Fire Place 203 Final Sign 204 Final Demolition OATE INTITIA SODEh INSPECTIONME 206 Final Mechanical 208 Finai Plumbing 210 FinalElectriWl 212 Final Fire Prevenlion 220 Final Planning Approval 222 Final Site 250 Final Building/OccuOancy �/�. �E� INTITIpLS WORKERS' COMPENSATION DECLARA710N: � I hereby aKrtn under penalry o/ perjury one of Ihe fo��....�ng declarations: ❑ I have antl vrill maintain a certificate o( consent to self-Insure for workers compensation, as provideG for by section 3700 of the Labor Code, (or the per(ormance of the work for whic� Nis Dermit is issuetl. . � � I �ave and will maintain workers' compensation insurance, as required by tion 3700 of the Labor Code. for Ihe pedormance of the wvrk fa which this pertnit is issued. My vrorkers' compensation Insurance carner and policy numbera�: � �`�c�-�1�, � "��� Carrier: �.{ 1 Y�� � w �—(rnissevenne�ea���/�ce�c'1omd �AMLepem�9fkvaWeOGa1 m�e'7nuntlretl/c;bqars(5i100)aiess) Policy Number: wl.i O� �l�[ ]��Y7�J L. � U��O l___ ❑ I certify that in ihe peAormance of the vrork for which this permit is issued, I shall not employ any person in any manner so as to become subjecl to ihe workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions o! Section 3700 of ihe Labor Code,yWi811 forthwith comply with these pmvi5ion5. `Y ( J i[i GA pli n sSiBnaWre L,Data WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNIAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOILARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. LICENSED CONTRACTORS DECLARATION: I hereby affrm that I am licensed under provisions o( Chapter 9(Gommencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i in full for/ce} -a�nd Zeffect. C.Lic. # - � m�l._ L ) ( Class # �1/Y1 ` Comr to naWre Dat � -' _ CONSTRUCTION LENDING AGENCY: ❑ I hereby aKrm that there is a constructqn lentling aqency for Ihe peAormance of the work for which this permit is issued. (Sec. 3097, Civil Code). Lender's Name: Lender's Adtlress: SignaWre � . Owner ID vedfietl by Orive. ;e. ❑ Yes ❑ No �� Driver's License No. Expires: � Verification of Ownership by (rype of document, i.e. - property tax bill or deed): OWNER-BUILDER DECLARA110NS: I hereby affirm that under penalty ol perjury that I am EXEMP7 FROM THE CONTRACTORS LICENSE U1W tor the following reason (Sec. 7031.5, eusiness antl Professions Cotle: Any city or counry which requires a permit to construct, aNer, improve, demolish, or repair any strucNre. prior to its issuance, also requires the applicant for such permit to flle a signed statement lhat he or she is licensetl pursuant to the provisions of the Conlractors License Law (Chapter 9(commencing with Section 7000) of Division 3 of the Business and Professions Code) or thal he or she is ezempl Iherefrom antl the basis for the alleged exemption. Any violation of Section 7031.5 Dy any applicant for a permit subjects Ihe applicanl to a civil penally of nol more Ihan fve hundred dollars ($500�.): ❑ I, as owner of the property, or my employees with wdges as their sole compensation, WILL DO THE WORK, and ihe strvcture is not intentled or offered for sale (Sec. 7044, Business and Protessions Code: The Contractors License Law does not apply lo an ovmer of property who builds or improves [hereon, and who does such vrork himself or herself or Ihrough his or her ovm employees, provided that such improvements are not intended or oHered for � sale. If, however, �he building or improvement is sold within one year o( completion, the owner-builtler will have Ihe burtlen of•proving tha[ he or she did not build or improve for purpose of sale.). . ❑ I, as owner of the property, am EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS to conslruct the project (Sec. 7044, Business and Professbns Code: The cont2ctors License Law dces not appty to�an owner of � property who builds or improves thereon, and who contracts for such project vrith a contractor(s) license pursuant to the Contractors Ucense Laws.). ❑ I am exempt under sec. Business and Professions Code for this reason: SignaWre Dale 305]i6 (3I01) DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION: . ❑ I hereby ceAify that no excavation (rve (5) or more feet in tlepth into which a person is required to descentl, will be made in connection with wvrk auttwrizetl by Ihis permit, antl that no building strucWre. scaFfGding, falsewark, or demolition or dismantling Ihereof, will be more than thirty-six (36) feet high. (Chap. 3.2, Grp 2, M 2, Sec. 341, Title 8, Califomia Administrative Code). ❑ As owner-builtler, I will not employ anyone to do work which vrould require a permit from Ihe Division of Industrial Safety, as noted above, unless such person has a permit to do such work from Ihe tlivision. ApPlicanl's SiB�aWre Dale Division of Industrial Safery Permit Number. HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION: 1. Will the applicant or present or future builtling occupant need to file and certify a Business Plan for emergency response to release or threatened release of a hazardous matenal? ❑ Yes ❑ No (Section 25505 0( Ihe Califomia Health and Safery Cotle requires, with some exceplions, ihal a Business Plan be filed with Ihe Costa Mesa Fire Department by every business which has at any one time during a reported year a quantity of hazardous materials equal to or greater than a weight of 500 pountls, or a volume of 55 gallons, or 200 cubic feet of compressetl gas al standard temperature antl pressure). 2. Does or will the applicant or present or future building occupanl need to file a registration lorm tor acutely hazartlous materials? ❑ Yes ❑ No (Section 25533 ot the California Health and Salely Cotle, with some exceptions, requires registration with the Costa Mesa Fire Department by each business which at any one time has on hand a quantity of acutely hazardous matedals equal to or greater than a weighl of 500 pountls, or a volume of 55 gallons, or 200 cubic feet ot compressed gas at standard temperature and pressure�. 3. Does or vnll the applicant or preseM or fuNre builtling occupant need to prepare an RMPP (Risk Managemeni and Prevention Program for acutely hazardous materials)7 ❑ Yes ❑ No (Section 25534 of the Cali(omia Health antl Safety Cotle provides [hat the Costa Mesa Fire Department may requira the preparation, certification and fling with the Fire Department of an RMPP Dy businesses v+hich are required ro register aately hazardous matedals vrith the Fire Department. 4. If an RMPP is presently required, has Section 25534 of the Califomia Health an0 Safety Cotle �een fully complied with? ❑ Ves ❑ No 5. Does or vrill the applicant or present or luture building occupant require for the work which is the subject of Ihis application a pertnit for such consWction or modification from the South Coast Air Qualiry Management District or trom any other air pollution control tlistnct or agency? ❑ Yes ❑ No (Sectbn 658502 of the Califomia Govemmen� Code requires that tt�e requested infortnation be fumished on applications for noo-residential building permits). 6. Will any part of the facility to 6e constructed under lhis permit 6e within 1000 feet (rom the outer boundaries o( a school? ❑ Yes ❑ No (If yes", the faciliry must meet the requirement of Sections 25534 and 42303 of Ihe California Health and Safery Code). 7. If a permit from the South Coast Air Quality M1fana9ement District or other air pollution wntrol district or agency is required for the work which is the subject o/ this application, have all of the discbsures prescnbed by Califomia Health and Safety Code Section 42303 been made? ❑ Yes ❑ No _ 8. Qf'yes"�,�attach cenifiwte of compliance from the appropriate air pollution control officer). , . CERTIFICATE OF COMPLIANCE;.I certify that under penalry of perjury the information given above �is cortecL I agree to comply with all state lav+s and ciry ordinances regarding Hazardous Matenals and Emissions: CERTIFICATE OF COMPLIANCE AND AUTHORIZATION OF ENTRY: I certify untler penalty of perjury that I have read this application and state that the information given is correct. I agree to comply with all state lavrs and city ordinances relating to building construction, and authorize representatives of the Ciry of Costa Mesa ro enter upon the ahove-describetl property for inspection purposes. I agree not to occupy or allow occupancy of any building authorized by this permit until fnal inspeclion. Sig LegalOwneqs) /�Da � Oc'� _ �� ( i An or AUl�onzeE ApP�'��nl - � Date � l_ To: Applicant: Address: Telephone Number. � � �C"l Tract/Parcel and Lo! Location of Project: Number of Square Feet of: Residential Space Commercial and Industrial Space Commercia�lndustrial Projed is: (Check One) . �. NEWPORT-MESA UNIFIED SCHOOL DISTRICT CERTIFICATE OF COMPUANCE OF DEVELOPMENT FEES PURSUANT TO AB 1600 ANO A8 181 oF,-z�-zam�.._;.-= ���,.� �Gr :i_P. . . DDj.-'�%�l��i�"'v' v � �° 6647 (� City of Costa Mesa Distrid Receipt No. ( ) Ciry of NewpoA Beach ( ) Counly of Orange Plan Check No. � '� Warehouse R8D Movie Theater Mini-storage Heavy Industrial Regional Shops Light Industrial This projed is exempt because (�1 O✓O x 51.84 x S .30 _ Motel _ Bank _ Neighborhood Shops _ RacqueVHealth _ Hotel _ MediealOffice _ Office Park To�, �31► 2�j 20 Total Preschooi Auto Repair Hospital Large Ofice Office Bldg. Restaurant Fest Food This certifies that the abaye-named Developer/AppGcant has paid school faaqry (ees in comp6ance with Govemment Code sections 53080 and 65995. The Building Pemiifs for this square footage in fhis proposed development may now be issued by your jurisdic6on. Checks are to be made payable to Newport�ulesa Unified School ANMtlied The above representa5on as to square (ootage is We. App�cant agrees that if it is later detemtined that such representadons are not true, then this certificate shall automaticaly temtinate and the appro ' te Cily/County shall be notified. oa�e � ��-�l I.� 1 �� � � : ARNET EPTGINEERING, INC. 1577 North Main Street, Suite A Orange, CA 92867 (714)379-3789 Fax:(714)379-8024 FAX'I'RANSMITTAL COVER SHEET FAX TO: Western National " FAX NO: Hand-Delivered ATTN: Bob Hemandez DATE: 8/16/07 FROM: Beat Arnet TIlVEC: PROJECT: Enclave / The Irvine Company 416 Enclave �/ Building Permit No. BC07-00054-� Total number of pages is I, including this cover sheet (Please call if you do not receive all pages, or if transmission is illegible). MESSAGES/COMMENTS: The "Structural Observation" per UBC 1702 regazding suand and rebaz layout was performed by me on August 16, 2007 on the following portions of the Post-Tensioned Slab-on-Grade of the above referenced project: Building #29 (1 A) The installations are in general conformance to the plans. Feel free to call me, if you should have any question. Sincerely, ARNE FiINEERING, INC. Beat Arnet, P.E. �,,, cc: Roberto Ortiz Fax 997-3857 v Ci Qi�40U �, r-`r Exp.3/32;�; �.,;,; r ., Name: �-AC ro.Ck I()�t —Z Date: � � - v� Pro'ect No. �)��- � Permit No. Il� U7" l/� �� The footing excavations listed above were observed and probed and found to bottom on firm competent bearing material. � � �The above listed slab subgrades were observed and testetl and found to have satisfactory moisture penetration to the recommended depth, and were found to be firm and dense. "' � (� The above listed interior trenches were observed and found to be backfilled with clean sand which were u densified by jetting and flooding with water. ❑The curb and gutter / street subgrade listed above was observed, probed and tested and found to be firm and unyielding with a minimum of 90% relative compaction. ❑The aggregate base listed above was observed and tested and found to be firm and unyielding with a minimum of 95% relative compaction. ❑The retaining wall backdrain listed above was observed and found to be installed in compliance with our recommendatiqns. ❑The subgrade listed above was observed, probed and tested, and found to be of firm bearing soils, adequately presaturated per our recommendations. Remarks: N es: he observations reported above do not constitute an approval o( foundation location, footing size or depth, reinforcement or foundation design. � Debris and slough should be removed prior to placemenl of reinfo/rce�ment or co ete ' . / l �J �"�j .�r.� ..�.,, NMG FIELD MEMORANDUM RP.CP.IVP.CJ bVf ��I i�.�. -, � , .- , � _ , , �. � :; � ..� _. ���.. .`�'-'i fd E F R 1 t7 G August 16, 2007 Inspection Division City of Costa Mesa Building & Safety 77 Fair Drive Costa Mesa, CA 92628 Attention: Subject: City Grading Inspector Civil Engineer's Certification of Compliance for Top of Forms Project: Grading Permit No Building Site: Buildings: Job Address: Owner: Work Completed: G06-00029 Enclave 29, 46, Pool Equipment Bldg & G13 450 Mton Blvd. IAC August 15, 2007 5�.� nu y � Infon�i Fn,pi, �- ot��.•', ,at: In accordance with the City of Costa Mesa Grading and Excavation Code and the requireme�ts of the Building Code, I certify approval of this project as outlined above, to top of bldg forms. Top of Forms has been completed substantially in conformance with the approved grading plan for this project and in full compliance with said Codes. Certification includes horizontal and vertical control and positive building pad drainage. This certification does not include approval of the placeme�t and compaction of earthwork within the purview of others. Sincerely, FUSCOE ENGINEERING, INC. � Trevor Scott Dodson, P.E. RCE 42029 Exp. 03/31 /O8 ��Q�,oQscorroo� s � � o W No.42029 z 2 \* / CIVi� ��Q' �F C Al.\F�/ 16795 Von Karman, Suite 700, irvine, Californio 92606 � tel 949.474J960 '� fox 9d9.474,5315 ^ www.fuscoe.com DALE CHRISTIAN/ STRIK7URAL EtVG1NEER, ING C0t�6UL7TNG 8 DFSIGN 1 �s8 Wat KateDa Ax�ue �Qange, U. 92867 774997I145 7749973857FAX <dalechrislian.com> DCSE,'Inc. Job Name: The Enclave Phase III DCSE,Inc. Job #: 06060 FIELD OBSERVATlON LOG �BEE NOTEB BELOII� t31dg. Type & Lot #: __> ��d �q �} Artival at DcpaAun from � IM�aU ol Supe�inte�arrt � Dato Engineer � Items Observed end I.ocetions . Stems Job Site l06 Site � � O.ok �'iSrO �D . �..3p y :3o Pre-Slab: Fp� ec.oro _ �,Ar1�5 �,�5 ✓ o, r�m mm�. W� ' O,ok 2nd Floor Framing o. r�a., mm�. wonc O, ok 3rd Floor Framing o, n�oea. me�. won� o. oR Roof Framing o. wae. man. wa�c NOMs: 1- A mmimum of 3-Irz Ne. will be c0e�gcA [m eecU end cvmy visi� tn Nc�oD s�te. 2-This fwm is onty for edmini�tlntive pu(pose md does mt i�irau atruciumi npprove� of eny buildiuB. If building confo�mmm lettu is iequirtd, supaintendent aMuld contect ILe wginw af `cmd m Dale Chriztian�s af6ce. I• Project Name: ' Project No: Date: Report No. 3r�C � Ti�lG GJ`�GL4V� APrS G 5�93 - c Z �G/o� Location: Author: / Day: �I� C^����V� S� A!X IJ M T W T S S CliendContraf tor: / nrz r,,,1E -L SupUForeman: �Qn/ rur+� o Weather: 'Tac / GvES7Exa N.cL � i uni�..✓ Field Supervisor. Geologisc � I Engineer: � Obsmation/I'esting oC Txh ' pR6 P�vR ��SP�cn�•� ' TyPc /A2 .Sri I Hours � � I [3L.�t, �� ERr�, r u - ovoS Equipment Working: Summary of Operations: A�t�vE r�,.� s�rc P �x .�r, �� � Ev�ri/ rJSP��ro� o� .a. �v= , L�5*� u3S��"r. TllG RGl3�++� wA3 CNEcrt�j „n ,Z= P�•ccwl6rr _,aP � fcE.>R,�•.�c�, TrIC. Pr T�,.���Nj r..�c2c- C�J_cccc� �� i .t�.+�'�f L'iCEN1CNT Nf—�?N�n � .Q.�C(-1qQA �T iS ✓ � ����� /-laQ-T TNG c� € TN� P r TE�xa� ,a�a ,a r�„-�r,o� ,,,nPLr.��cG ,T�./ ApPK�e� LRN 5. ' T `�'7 - S! rc E+� v � i Page i of ! Received by: FIELD REPORT _ MG NMG GEOTECHNICAL, INC. White - File Copy Yellow - Client Copy Pink - CliendAgency Copy Gold - Field Copy WESTERN NATIONAL CONTRAC' S 8 EXECU7fVE CIRCLE � IRVINE, CA 92614-6746 Ph:(949)862-6200 Letter of Transmittal To: HENRY MARTINEZ CITY OF COSTA MESA 77 FAIR DRIVE COSTA MESA, CA 92628 Ph:(714)754-5652 Fax:714 754-4856 Subject: ENCLAVE BUILDING CERTIFICATIONS WE ARE SENDING YOU �" Shop drawings C" Copy of letter Letter of CeRification Letter of Certification Lefter of Certification Letter of Certification Letter of Certification Letter of Certification Letter of CeRification Letter of Certification Letter of Certification Letter of Certification p Attached C Pnnts t� Change order L C C C C 0 C C C � � Date THESE ARE TRANSMITTED as checked below: Transmittal #: 293 Date: 6/19/2008 Job: 10-193 THE ENCLAVE t"' Under separate cover via None the following items: C Plans t" Samples fy Specifications C'� Other No. Descri tion 1 Fuscoe Engineering - c � Arnet Engineering - � Dale Christian - � NMG Geotechnical - 1 CitY of Costa Mesa - 1 DRI - Roofng Gateway Insulation AMPAM Parks - Pli Residential Electric LDI Mechanical � For approval t- Approved as submitted t"' Resubmit _ copies for,approval r For your use C" Approved as noted C." Submit _ copies for distribution � As requested � Returned for corrections � Return _ corrected prints C` For review and comment C" Ofher [W FOR BIDS DUE i" PRINTS RETURNED AFTER LOAN TO US Remarks: BUILDING 29 Copy To: Received: / Henry Martinez Date If enctosures are not es noted, kindly natily us at ance. Page 1 of 2 � ���°�Q ��DOoo o � � �J �O LS E N G 1 N E E R I N G June 9, 2008 Inspection Division CITY OF COSTA MESA Building & Safety 77 Fair Drive Costa Mesa, CA 92628 Attention Subject City Grading Inspector Civil Engineer's Certification of Compliance for Precise Grading Project: Grading Permit No Building Site: Building: Job Address: Owner: Work Completed: GOb-00029 Enclave 29 450 Anton Blvd. IAC June 6, 2008 San Diego Inland Empire Palm Springs In accordance with the City of Costa Mesa Grading Excavation Code and the requirements of the Building Code, I certify approval of this project as outlined above, for Precise Grading. Precise Grading for building 29 has been completed substantially in conformance with the approved grading plan for this project and in full compliance with said Codes, pending any revisions that may come later. Certification includes horizontal and verticol control. Sincerely, FUSCOE ENGINEERING, INC. ��� Trevor Scott Dodson, P.E. RCE42029 Exp. 03/31 / 10 / u 1 I c i r< I e f h i n k i n g 16795 Von Karman, Suife 100, Irvine, California 92606 � tel 949.474.1960 � fax 949.474.5315 � www.fuscoe.com AI2NET ENGINEERING, INC. 1577 North Main Street, Suite A Orange, CA 92867 (714)379-3789 Fax:(714)379-8024 FAX TRANSMITTAL COVER SHEET F'AX TO: Western National FAX NO: Hand-Delivered ATTN: Bob Hernandez DATE: 8/16/07 FROM: Beat Arnet T[ME: PROJECT: Enclave / The Irvine Company 416 Enclave / Building Permit No. BC07-00054 Total number of pages is 1, including this cover sheet (Please call if you do not receive all pages, or if transmission is iliegible}. MESSAGES/COMMENTS: Dear Bob: The "Structural Observation" per UBC 1702 regarding strand and rebar layout was performed by me on August 16, 2007 on the following portions of the Post-Tensioned Slab-on-Grade of the above referenced project: Building #29 (1 A) The installations are in general conformance to the plans. Feel free to call me, if you should have any question. Sincerely, ARNE INEERING, INC. Beat Arnet, P.E. cc: Roberto Ortiz FaY 997-3857 � C 0404&G r � Exp.3/31/09 � .� DALE CHRISTL4N/ STRUCNRAL ENGINEER, INC. CONSULTING � DFSIGN 1744 West Katella �venue Suite 107 Orange U 92867 PH 714 997 1 I45 FX 714 997 3857 March 26, 2008 Mr. Jerry Crosby Western National Construction 8 Executive Cirde Irvine, CA 92614 Re: T'he Enclave — Phase III —(Building 29 - concrete and framing) Irviue Apartment Communities (Our Job No. 06060) Deaz Ivlr. Crosby: Pursuant to yoiu request, ihis office hac made several site visits to the above descnbed project The p�upose of Ihe visit on August 2, 2007 was to observe the placemeni of the various holddown 6ardware prior to the concrete pour. Buildiag 29 was observed dwing this visit Deficient items, some quite minor, wete brougUt to the attention of tLe concrete foreman and were corrected during the pre-slab visit and Building 29 appeared to be in substanrial conformance with structuial drawings. This office made a site visit on January 2, 2008, to observe rough fiaming for the above mentioned building for substautial confo�ance to the shuctival plans. Deficient items, some were quite minor, were discussed with either Tony Ramos with Westem National Construction or TWR's Framing Foreman. Observed deficient items were coirected and the rough framing appeared to be in substantial confomnance with the structunl drawings by the time ow� visits were complete. These observations are intended only to azsist the framing contractor in conformance with the shucttual plaos as they relaze to U�is residential aparhneat project and are not to be construed as "Special Inspections”. The responsibility for such plan conformance, of course, remains with the contractor. Please do not hesitate to contact me at my office should you have any fiuther quesbons regazding the site observatioq or with information included in this report. Sincerely, � V Dale A. Christian, S.E. 2705 President cc: Tom Hilton JoLn Hyde G:\WORD_poc106�06060�Phase Mf0 LetterslBuilding 29.doc �iv����,�'P CHq�s� � v, � Z ro � No.2i05 C Exp.3•31-10 ? � �:� i � sr uc1��'P .,_ ; \�'r A /:`� \ OF C A�-��% NMG rt�a;,»w,'y?.�'W;'Fi',uT<�i�'g Geotechnical, Inc. May 16, 2008 Project No. 04093-01 Precise Permit No.: G06-00029 "I�o: In�ine Apartment Communities I 10 Innovation Drive Irvine, California 92617 Attention: Mr. Tom Hilton Subject: Summary of Geotechnical Observation and Testing during Precise and Post Grading Operations, and Special [nspection Services for Buildings 22 through 36 and Garages G-I, G-10 through G-12 and G-14 through G-16, The Enclave Apartment Community, City of Costa Mesa, County of Orange, Califomia As requested, NMG Geotechnical, Inc. WM6) has prepared this document to present the results of our geotechnical observation and testing during the precise and post grading operations, and our special inspection services at the subject site. Our services during gading activities included observation and testing during utility line trench backfill, footing excavations, and hardscape subgrade preparations. In addition, NMG has performed special inspection services, including structural concrete reinforcement; structural concrete placement; stressing of post-tension cables; welding; hardware epoxy fix; and concrete compressive strength testing. Based on our observation and testing, the above improvements were performed in substantial compliance with our recommendation, project specification, and the requirements of the City of Costa Mesa. Details of our observation and testing, including field density test results and locations will be provided in separate reports. If you have any ques[ions regarding this repoR, please contact our office. We appreciate the opportunity to provide our services. Respectfully submitted, NMG GEOTECHNICAL, INC. "�/`�� Sha rooz "Bob" Karimi, RCE 54250 Principal Engineer SBK/jC No.0054250 � EXP. 12/09 * 's'T,q� CIVIL 0���/ � OFr.e�lf Distribution: (2) Addressee (23) Mr. Bob Hemandez, Western National Contractors (includes copies for submittal to the City of Costa Mesa) 17991 Fiech • Irvine, California 92614 • PHONE (949) 442-2442 • FAX (949) 476-8322 /3nar�/ of Di�ectors Arl Pcrrv �rlrnc Sr.hnJirr Bab Onr<�r� .lumc.c Ferr�vnqn Cinrl' Mrrnn6nn Stqlr' Rohiu (i. ilarner,r Mana,ger Di.�yrict Gn,ginerr f949) 631-173 / 77��mms A. Fntnh A.�tcistrtnl Mnnager Joru� Rcvak liom�d Secrelurv i'rogrnr» Mann,�er Cler'k o/'�hr. Di.rlrict Alart R. Burrts Legal Cn,insef � � Mttrcua' D. Dovia� Tr��ru�pm�/Uiret7nr nf. Finmir,e Plione �949) (45-5400 Fas (9d9) 650-22s3 Addreatc 628 W. l9rh Srrerr Co.rra Mc.cn. CA 92(27-27/6 Oa dm a r� r��«-�r „�� Rr�)�rlyd Vaprr ��� .����. ��.����.�� �������� . . . an In)epen�ent Specia[ District SEWER INSPECTION LOG FINAL SIGN-OFF ENCLAVE 1'RACT # 10950 BUILllING 27 418 (20 units) 20 ki[chen sinks 201aundry wbs/washers 28 bathmbs 28 wash basins 20 water closels BUILDING 28 417 (20 units) 20 kitchen sinl:s 201aundry tubs/washers 28 bathtubs 28 wash basins 20 water closets BUILDING 29 416 (20 units) 20 kitchen sinks 20 laundry wbs/washers 28 bathwbs 28 wash basins 20 water closets � Joe � � s -a�-°� Date Finaled Protecting our communitv�s G�ea�tl� br� proviaing so[i� waste ana sewer co[(ection services. www.crosaca.gov Property Address � CITY OF COS7'A MESA ' BUILDIPdG DIVISION �0�� COV���9�ffl1C� C����9C���0� Permit No. BC07-00054 The Enclave; B1dg.29,Type lA, 416 Enclave, Costa Mesa, CA 9262E Owner The Irvine Company, LLC. A Delaware Limited Partnership Contractor DRI Residential Corporation State Contractor License Number $19960 Classification C3 9 1 hereby certity that I have installed, or caused to be installed. a minimum Class C roof covering at ihe above atldress in conformance with Chapter 15, end Appendix 15 of the iatest adopted edition af the Uniform Buiiding Code, and the tnstaltaqon instrucYions of the menufacturer. ❑ I turther certify that I am the owner of ihe property. (Owner-Builder permittee ony). ❑ I funher certiy that I am: ❑ Owner of sole proprfetorship company ❑ FWI partner of the company ❑ l imited partner ot the compa�y ❑ OHicer of the corporation ! certity thal as an authorized officer or agant ot ihe company or corpwation, I am empowered to make thls certNicflUon, which ShaU be bintling on ap Successors or assigns of the company or corpordtion. I shall deliver a copy of this Certification to the above Gsted owner, after submittal oi form to the Bullding Division for acoeptern:e. Reoeivetl by Building Division By: M9P�6 MW 690 NTb � Bu�M4 Ox. f:rw�Y � Camacv. v.w . qrrw DRI Residential Corporation cAmpa�r or cAmomre Hame 17182 Armstrong Avenue nddreu Irvine, CA 92614 � May 29, 2008 ture Date Patrick Kay; Vice President Operations P�mwC o� Typod Namp � • ! _ - r , ` J'j_ ;`•, THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN COMFORMANCE WITH THE CURRENT ENERGY REGULATIONS, CALIFORNIA ADMINISTRATNE CODE, TITLE 24, STATE OF CALIFORNIA, IN THE BUILD[NG LOCATED AT: SITE ADDRESS: a16 ENCLAVE, IRVINE CA. EXTER[OR WALLS MANUFACTURER-CERTAINTEED THICKNESS/CYPE-3.5^FBERGLASS RNALUE - R 13 EXPOSED FLOOR MANUFACTURER - CERTAINTEED THICKNESS/TYPE - 615" FIBERGLASS RNALUE - R19 CEILINGS BLOW:MANUFACTURER-CERTAINTEED THICKNESS/TYPE-12"FIBERGLASS RNALUE - R30 GENERAL CONTRACTOR: WNC LICENSE # INSULATION CONTRACTOR: GATEWAY INSULATION, INC. L[CENSE # 797001 BY: � TITLE: OPERATIONS MGR. DATE: 5/9/2008 BUTCH INGRAM OPERATIONS MANAGER. ��� �� INSTALLATION C� _TIFICATE Site Addr s 1 of Permit Number C�� M installation certificate is required to be posted at the building si[e or made available for all appropriate inspections. (The information pmvided on this form is required; however, use of this form to pcovide the information is optionaL) After completion of final inspectioq a copy must be provided to the building department (upon request) and the building owncr at occupaocy, per Sectiou ] 0-1 D3(b). HVAC SYSTEMS: Heating Equipment Equip. ' M of E�cirney Duct Duc[ or Hra[ing Hea[ing Type (pkg. CEC Certified Mfr Name Ideutical (A£UE, etc.)� Lncation Piping Load Capacity h to 1 nd M delN mb Svst ms f2CF-lRvalu 1 (etti t 1 R- nl fHtu/hr) lBtu/h 1 Coo[irtg Equipment Equip. CEC Certfied Comprrssor k of Effwirnry Duct Coaling Caoling Type (pkg. Unit Mfr Nazne end Idrntical (SEER, cm.)� Loca�on Duct Load Capacity hcet oumol Modcl Numbcr Svstems f2CF-IR �aluel (attic, ctc.l R-value fHeu/hd lBtu/hrl 1. > reads greater than or equal to. ' I, the undasigoed, verify that equipment iisted above is: 1) is the actual equipment installed, 2) equivalent to or more efficieut than that specified io the certificate of compliance (Fortn CF-1R) submitted for compliance with the Energy E�cienry Srondards for residen[ial buildings, and 3) equipment Iha[ meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Ejficieney Regulotions or Part 6), where applicable. Date WATER HEATING SYSTEMS: siR�pi�=DRv ik!!!/YL Hrater CEC Ccrtified Mfr Twe Name & Model Numl Dishibution IfRccir- Type (Std, cuiatiou, 'oiaraf-Usel Coutrol Tv Installing Subconhactor (Co. Name) � OA General Contractor (Co. Name) OR Owner N of Rffied� Tauk identical laput(kW Voiume S stcros or BtWhr allons` ���_. �- Effi- Extcmal irnc� Staudh� Insulation 2 For smali gas t[orage (aicd iuput oflas than or equal Io 75,000 Bnilhr), dectrie rcsistance avd hent pump water hea[en, lis[ Hncrgy Factor. For large gu [tonge waur hnters (mted input of g[eater than 75,U00 BhJhr), list Rewvery Efficirncy, $taodby Loss end Rated Input. For instan[aneous gaz water heater5, list Recovery Efficienry and Rn[ed loput. 3. R-I2 eztemal insularian is mandzWry' for seonge watec heatets with ea rnergy faclor of less Ihan 0.58. Faucets & Shower Heads: All faucets and showerheads iosta(led are certified to the Gommission, pursuant to Title 24, Part 6, Section 1] 1. I, the undeisigned, verify thai equipment Listed above my signature is: 1) the actual equipment ins[alled; 2) equivalent to or more effici t ar� at specified in Ihe certificate of compliance (Form CF-1R) submitted for compliance with the Ett dards for residential buildings; and 3) equipmen[ that meeLs or exceeds the appropriate re �rem r acNred devices (from the Applianee E�ciency Regulations or Pari 6), where applicable. � 9 D8 �M�e.k-s �'l���q j_. Si amre, D t Instal3ing Subcontractor (Co. Name) OR Geoeral Contractor (Co. Name) OR Owner . COPY . � ding Depamnent HERS Provider (if applicable) Building Owner at Occupancy Compliance Forms August2001 A-23 //��� RESIDEf ,AL ELECTRIC ASSOCI, cS, INC. REA� 0 19—�Q' Contractor License #610435 L� www.reselectric.com May 9, 2Q08 City of Costa Mesa 77 Fair Dr. Costa Mesa, CA 92626 Attn: Randy Buck RE: Contractor: Western ;Vational Project: The Enclave 450 Anton Blvd. Costa Mesa, CA Building #29 Address 416 Dear Randy, The electrical work on these buildings complies with the Califomia Title 24 Requirements. Sincerely, .� G����� � / Bob Tripp General Manager Corporafe Address Sania Ana Division 123 Rose Drive, Fullerton, CA 92833 3240 S. Standard Ave., Santa Ana, CA 9270.5 Phone (714) 278-0400 Fax pl4) 278-0600 Phone pl4) 556-3813 Fax pl4) 556-3929 INSTALLATION Enclave Building #29 Site Address: Irvine, Ca � CF-6R Permit # M instalfadon certificate is required to be posted at the building sife or made availabie for all appropnate inspections. (The infom�apon provided on this fwm is required; howeveq use of this fortn to provide the information is optionl.) Af[er wmpletion of final inspection, a copy must 6e pmvided to the building deparlment (upon tequcst) end the buildi¢g owner af occupancy, per secfion 70-] 03(b). HVAC SYSTEMS: Heating Equiprnent Equip. Type (pkg. heat CEC Catified Mfr, Make & pump, etc.} Model Number Hydronic First Company 18CDXQ-F-C Hydronic First Company 25C➢XQ-F-C # of Efficiency Duct Duct or Heating Heating Identical (AFUE,etc.)' Locaaon Piping Load Capaciry S�Stems [2CF-iR value] (attic, etcJ R-valuc (Btu/hr1 (B7U/EIr) 10 soft"it R-4.2 18,000 10 soffit R-0? 25,000 Coolirtg Equiprxent Equip. Type . # of Effecirncy (pkg. heat CEC Cerafied Compressor Unit Identical (SEER, ac) PumP, �c.) MG. Name and Model Number Systems [>CF-7 R vah DX-Cooling Yark GCGD78S21SI 10 t3.00 DX-Cooling York GCGD24S21S1 10 13.00 1>_ reads geatcr than or equal to. Duct Lowrion Duct attic, eteJ R-vslue soffit R-4.2 Cooling Cooling Load Capaciry 24,000 I, the undersigned, vertfy thst the equipmrnt listed abovo is: I) is the actual equipmrnt installed, (2) equivelrnt m or more efficient than that specified in die ccrtificate of wmpliance (Form CF-1R) submitied for compliance with the Energy Efficicncy Standards for residrntial buildings, and (3) equipmrnt that meets or ezceeds the appropriate requirements for manufactured devices (from the Applianee Efficiency Regulations or Part 6), where applicable. t �--- LDIMechenicel Lorrafne Bernendez HVAC Subcontractor (Co. Name) OR Grneral Coutractor OR Owner WATER AEATING SYSTEMS: l;Water CEC Certified Distribution If Recir- Rated Input Tank Efficimcy Standby Extemal Heater Mfr Name & Type (Std, culatioM # of Idrntical (kW or Volume (EF, RE) Loss (%) Insulation R- Typd# Model Numba Poin4of•Use) Control Type Systems Btu/hr) (gallons) velue FAUCETS & SHOWER HEADS: All faucets and showerheads instailed are Iisted in the Commisions Directory of Cerrified Faucets and Showerheads, pucsuant to Titl�24, part 6, Subchapter 2, Sxtion I 11. I, the undersigned, vefify tLat t6c equipment listed in the category above my signatu}e is the actual equipment installed end that the equipment meets w o:cuds the requirements of tt�e Applienec Efficimcy Standards. ]n addirion, I have verifi�d that the equipment is equivalrnt to or morc ef£cient than the equipmmt specified on the Certificate of Compliance submitted W demonstrste compliance with the Energy EfHcirncy Standards for residential buildings. Signatiue, Date COPY TO: @uildiug Departrnent $8RS Provida (if applicable) $uildin� Owntt at Occupancy Plumbing Subwotractor (Co. Name) OR Grneral Contracror OR Owner