Loading...
HomeMy WebLinkAbout- - PA 0918 Supplemental Memo - 8/3/2010CITY COUNCIL SUPPLEMENTAL MEMORANDUM MEETING DATE: AUGUST 3, 2010 SUBJECT: REQUEST FOR REHEARING OF PLANNING APPLICATION PA -09-18: MASTER PLAN FOR A MIXED USE, 53 -UNIT, 4 -STORY, SENIOR HOUSING AND 4,980 SQ. FT. RETAIL COMMERCIAL PROJECT AT 845 BAKER STREET DATE: JULY 28, 2010 FOR FURTHER INFORMATION CONTACT: MEL LEE, SENIOR PLANNER (714) 754-5611 (mlee@ci.costa-mesa.cams) Attached for your reference is the noise study prepared for the Baker Street Lofts Project at 801 Baker Street referenced in Mayor Pro Tem Wendy Leece's rehearing request. 41-1- Mtl LEE, AICP Senior Planner Attachment: 1. Noise Study Distribution: City Manager Asst. City Manager City Attorney Dev. Svs. Director Public Services Director Transportation Services Manager City Clerk (2) Staff (4) Planning Staff (8) File (2) Eric A. Nelson 1234 E. 17th Street Santa Ana, CA 92701 KIMBERLY B DT, AICP Development Svs. Director Jan R. Hochhauser, AIA Hochhauser Blatter Architecture + Planning 122 E. Arrellaga Street Santa Barbara, CA 93101 Arthur M. May, AIA Senior Vice President USA Properties Fund 2440 Professional Drive Roseville, CA 95661-7773 Larry McElwain Architectural Development Manager USA Properties Fund 2440 Professional Drive Roseville, CA 95661-7773 Michelle Keldorf USA Properties Fund 3950 Paramount Blvd., Suite 101 Lakewood, CA 90712 Peter Buffa 2824 Nevis Circle Costa Mesa, CA 92626 File: 080310PA0918Su Memo Date: 072810 Time: 8:30 a.m. NOISE STUDY Baker Street Lofts Costa Mesa, California Prepared for: RED MOUNTAIN RETAIL GROUP Prepared by: PCR SERVICES CORPORATION March 2007 r TABLE OF CONTENTS Page 1. INTRODUCTION.....................................................................................................................1 1.1 Purpose............................................................................................................................I 1.2 Project Description..........................................................................................................1 2. NOISE ANALYSIS..............................................................................:....................................3 2.1 Noise Descriptors............................................................................................................3 2.1 City of Costa Mesa Requirements..................................................................................3 2.2 Existing Noise Environment...........................................................................................4 2.3 Sound Insulation Requirements......................................................................................5 3. NHTIGATION MEASURES..... 3.1 Exterior Construction......................................................................................................7 Red Mountain Retail Group PCR Services Corporation P ag, Balzer Street Lofts March 2007 F LIST OF FIGURES 'Figure PaLye Figure1 Project Site Plan...........................................................................................................2 Baker Street Lofts Red Mountain Retail Group March 2007 PCR Services Corporation Page LIST OF TABLES Table Page Table 1 Measured Ambient Noise Levels at Project Site ........................................... Baker Street Lofts Red Mountain Retail Group March 2007 PCR Services Corporation Page 1. INTRODUCTION 1.1 PURPOSE The purpose of this noise study is to: a. Measure and quantify the existing ambient noise environment at the proposed Project site; b. Evaluate the sound attenuation requirements of the proposed Project exterior building envelope with respect to the City of Costa Mesa's Noise Study requirement as stated in SoBECA Urban Plan adopted April 4, 2006 (Page 19); and c. Recommend, if needed, noise mitigation measures required to meet the interior sound level standard of 45 dBA CNEL as specified under SoBECA Urban Plan. 1.2 PROJECT DESCRIPTION Red Mountain Retail Group proposes to construct the Baker Street Lofts (Project) in the City of Costa Mesa: The proposed Project would add 21 -unit multi-level residential lofts above the existing single -story commercial building. The project site plan, shown on Figure 1 on page 2, is bounded by Baker Street to the north, Century Place to the east, and the 73 Freeway running diagonally to the southwest. Red Mountain Retail Group Baker Street Lofts March 2007 PCR Services Corporation Page . y � «> _a _ Mountain Retell Group, zzGoogle Earth, _ Ee] Si Plan S owbig Noise Monitoring Locations : _r _, 2. NOISE ANALYSIS 2.1 NOISE DESCRIPTORS The decibel (dB)' is a conventional unit for measuring the amplitude of sound because it accounts for the large variations in sound pressure amplitude and reflects the way people perceive changes in sound amplitude. When describing sound and its effect on a human population, A -weighted (dBA) sound levels are typically used to account for the response of the human ear. The term "A -weighted" refers to a filtering of the noise signal in a manner corresponding to the way the human ear perceives sound. Community noise levels usually change continuously during the day. The equivalent sound level (Leg) is normally used to describe community noise. The Lea is the equivalent steady-state A -weighted sound level that would contain the same acoustical energy as the time - varying .A -weighted sound_ level during the same time interval. For intermittent noise sources such as music, the maximum noise level (Lma.,) is normally used. The Lmax sound level represents the maximum noise level measured during the measurement. Another noise metric, commonly used for land use planning and is also used by the City of Costa Mesa, is the Community Noise Equivalent Level (CNEL). The CNEL adds a 5 dBA penalty to noise occurring during evening hours from 7:00 P.M. to 10:00 P.M., and a 10 dBA penalty to sounds occurring between the hours of 10:00 P.M. to 7:00 A.M. to account for the increased sensitivity to noise events that occur during the quiet late evening and nighttime periods. Thus, the CNEL noise metric provides a 24-hour average of A -weighted noise levels at a particular location, with an evening and a nighttime adjustment, which reflects increased sensitivity to noise during these times of the day. 2.1 CITY OF COSTA MESA REQUIREMENTS The SoBECA Urban Plan requirement with respect to noise study for the Project is stated as follows: • The residential interior noise levels shall be 45 CNEL or less; and All sound levels, measured in decibel (dB), in this study are relative to 2x10-5 N/mz Red Mountain Retail Group Baker Street Lofts March 2007 PCR Services Corporation Page Noise Study • The residential exterior noise levels in private open space areas shall be 65 CNEL or less. The residential exterior noise standards; however, are not applicable to multi- family residential development such as the Baker Street Lofts. • The City of Costa Mesa Noise Ordinance (Section 13-281) provides interior noise standard of maximum noise level of 55 dBA (for nighttime hours between 10 P.M. and 7 A.M.). The standard also states that for noise consists of music, the noise standard shall be reduced by 5 dBA. As applicable to this Project, the maximum interior noise level due to music shall be 50 dBA. 2.2 EXISTING NOISE ENVIRONMENT The existing noise environment at the proposed Project site is comprised primarily of auto traffic on the adjoining 73 Freeway, nearby local streets including Baker. Street; adjacent commercial operations including the existing nightclub (The Shark Club) on the abutting property (841 Baker Street), as shown on Figure 1. To quantify the existing noise. environment, long-term noise measurement was made from Saturday February 17 to Tuesday February 20, 2007. The ambient noise measurement extended through the weekend to include noise levels from operation of adjoining nightclub, which normally operates on weekend during the late nighttime hours. 2.2.1 Measurement Procedures Noise measurements were conducted using Larson -Davis 820 Precision Integrated Sound Level Meter (SLM). The Larson -Davis 820 SLM is a Type 1 standard instrument as defined in the American National Standard Institute (ANSI) SIA. All instruments were calibrated and operated according to the applicable manufacturer specification. The microphone was placed at a height of 5 feet above the roof elevation of the existing commercial building with direct line -of - sight to the 73 Freeway, Balser Street, and the nightclub. The sound level meter was setup to collect the hourly average noise level (Leq) used to calculated the 24-hour CNEL and the maximum noise level (Lmax) to document noise generated by the nightclub (during the late night hours). 2.2.2 Measurement Results Table 1 on page 5 presents the existing noise environment in the project vicinity. Based on field observation and measured sound data, the existing noise environment in the vicinity of the project site is controlled mainly by auto traffic and noise from the adjacent nightclub especially during the late night hours when the nightclub is in operation. As indicated on Table 1, the Project site is currently exposed to exterior noise level up to. 68.4 CNEL, Baiter Street Lofts Red Mountain Retail Group March 2007 PCR Services Corporation Page /D Date / Time Saturday 2/17/07 — 12 A.M. to 12 A.M. Sunday 2/18/07 — 12 A.M. to 12 A.M. Monday 2/19/07 — 12 A.M. to 12 A.M. Tuesday 2/20/07 — 12 A.M. to 10 A.M. Table 1 Noise Study Measured Ambient Noise Levels at Project Site Nighttime L.,,, 24-hour CNEL Mainly due to nightclub operation (dBA) (dBA) Notes 68.4 75 to 83 Nightclub Open (10 P.M. Fri. to 3 A.M. Sat.) 68,2 72 to 82 Nightclub Open (10 P.M. Sat. to 3 A.M. Sun.) 65.5 64 to 71 Nightclub Closed (10 P.M. Sun to 3 A.M. Mon) e 61 to 67 Nightclub Closed (10 P.M. Mon to 3 A.M. Tue) ° Measurement was less than 24 hours. Source: PCR Services Corporation, 2007 During the late night hours (between 10 P.M. and 3 A.M.) when the nightclub is in operation (i.e.,- Friday and Saturday nights), the maximum noise level (Lmax) of 83 dBA was recorded at the Project site., which is up to 22 dBA higher than the nights when the night club is closed (i.e., Sunday and Monday nights). 2.3 SOUND INSULATION REQUIREMENTS In order to meet the SoBECA Urban Plan interior noise limit of 45 dBA CNEL the proposed building exterior envelope must provide a minimum of 24 dBA exterior/interior noise reduction. This translates to a minimum Sound Transmission Class (STC) STC 34 rating for exterior construction including; building fagade, windows, doors, and roofs. The City noise standard of 45 CNEL interior noise level is normally adequate for general environmental noise sources, such as traffic or other continuous and steady state noise sources (e.g. building mechanical equipment). However; as mentioned in the previous section, the Project site is also exposed to short term but significant noise levels due to operation of the adjacent nightclub. The nightclub nighttime operation noise level was measured up to 83 dBA at the future site of the proposed residential building. The high noise level generated by the nightclub during the late night hours could be a potential noise impacts to interior environment of the proposed Project. Furthermore, the nightclub related activities, as reported by Red z Sound Transmission Class, STC, is a single number acoustic rating for building construction, indicating the noise reduction performance. The higher STC rating represents a higher acoustic performance or higher noise reduction Red Mountain Retail Group Baker Street Lofts PCR Services Corporation March 2007 Page Noise Study Mountain Retail Group, noise generation is primarily from musical instruments, bands and broadcast stereo systems with low bass (low frequency). As such the Project should also comply with the City of Costa Mesa Noise Ordinance Section 13-281 (described in Section 2.1 above), that is, reduce the exterior noise from the adjacent Shark Club (83 dBA maximum noise level) to the interior of the residential units (50 dBA maximum noise level). The Project exterior walls/windows and doors construction, therefore, should provide sound attenuation, of no less than 33 dBA or minimum STC 43 rating. Red Mountain Retail Group Balser Street Lofts March 2007 PCR Services Corporation Page /; 3. MITIGATION MEASURES 3.1 EXTERIOR CONSTRUCTION The following mitigation measures are recommended to meet the City's sound insulation requirements. As the project is in preliminary design phase, final construction materials are not yet selected. Therefore, mitigation measures are specified in terms of acoustic performances. 1. West and North Facades of Residential Units facing the Shark Club: a. Wall — Minimum STC 43. Typical exterior wall construction, such as stucco on wood studs and gypsum wall panels, would meet STC 43. If other type of wall system is use, project design specification shall include acoustic data indicating the specified system meet minimum STC requirement. b.W indows — Minimum STC 43 rating. Project design specification shall include manufacturer's acoustic data indicating the specified window assemblies meet minimum STC requirement. c. Doors — Minimum STC 38. Acoustic rated assembly. Project design specification shall include manufacturer's acoustic data indicating the specified door assemblies meet minimum STC requirement. 2. East and South Facades of Units not facing the Shark Club: a. Wall — Minimum STC 34. Typical exterior wall construction, such as stucco on wood studs and gypsum wall panels, would meet STC 34. If other type of wall system is use, project design specification shall include acoustic data indicating the specified system meet minimum STC requirement. b.W indows — Minimum STC 34 rating. Project design specification shall include manufacturer's acoustic data indicating the specified window meet minimum STC requirement. c. Doors — Minimum STC 29. Solid core wood or insulated metal door with a full set of acoustics seal would meet this requirement. Red Mountain Retail Group Baker Street Lofts March 2007 PCR Services Corporation Page 13