HomeMy WebLinkAbout1824 VIOLA PL - Building Permits CITY OF COSTA MESA
aloisRipBUILDING DIVISION
:,211.1,1511 77 FAIR DRIVE,COSTA MESA,CA 92626 • (714)754-5273 • Fax(714)754-4856 • www.ci.costa-mesa.ca.us
;) 111040 FOR INSPECTIONS CALL: (714)754-5626
PERMIT NUMBER: B11-00287
PERMIT TYPE B_ROOF2 STATUS: ISSUED
APN: 42424116 DATE ISSUED: 09/07/2011
ISSUED BY: RMD
JOB ADDRESS: 1824 VIOLA PL CM Suite/Unit:
Vicinity: HOUSE AND GARAGE ROOF
Squares: 2200 Valuation: $6,000.00
SCOPE OF WORK: TEAR OFF EXISTING ROOF MATERIALS INSTALL 1 LAYER OF 30#FELT ON A 4:12 PITCHED ROOF AND
REROOF WITH 30 YEAR COMP SHINGLES ON AN ATTACHED HOUSE AND GARAGE,APPROX 22 SQUARES. REPAIR
AND REPLACE SHEATHING AS NEEDED. COMPLIANCE FORMS ATTACHED TO JOB CARD AND CITY PERMIT.
NOTE:RESIDENTIAL RE-ROOF: Final approval of permit shall not be granted until access to dwelling unit(s) is provided for
verification of the installation of smoke and carbon monoxide alarms by the City Inspector. See Attachment w/Inspection Card
OWNER: NAQVI,AU J Address: 1914 YVONNE ST Unit:
PHONE: 626-827-6808 City/State/Zip: WEST COVINA,CA
APPLICANT: BONILLA, FRANCISCO Address: Unit: :
PHONE: 714-748-4259 City/State/Zip:
CONTRACTOR: BONILLA ROOFING License No. 885049
Address: 12002 MORGAN LNUnit: PHONE: 714-748-4259
City/State/Zip: GARDEN GROVE, CA 92840 CELL:
ARCHITECT: License No. PHONE:
ENGINEER: License No. PHONE:
FEE SUMMARY
Reroof Plan Check: $0.00
Reroof Permit Fee: $125.25
Reinspection Fee: $0.00
Bldg Std Admin Fund $1.00
•
TOTAL FEES $126.25
HOURS FOR CONSTRUCTION ACTIVITY; EFFECTIVE 3/18/2010 -PER CMMC Sec. 13-279
Monday thru Friday-7:00 am thru 7:00 pm. Saturdays-9:00 am thru 6:00 pm. Prohibitied all hours-Sundays and the following Federal holidays
New Years Day, Memorial Day, Independence Day, Labor Day,Thanksgiving Day and Christmas Day
NOTICE: The work authorized by this permit shall comply with all applicable handicap access requirements under California statutes and related
regulations. (Ord. No.92-28, § 1, 12-21-92)
EXPIRATION: PERMIT EXPIRES 180 DAYS FROM DATE OF ISSUE OR DATE OF LAST INSPECTION.
INSPECTIONS: In order for the work authorized under this permit to be considered legal, such work must comply with all applicable codes, and all
required inspections and final approval must be obtained. Failure to obtain inspections and final approval will result in the expiration of this permit.
CODEC. INSPECTION TYPE DATE INn11ALS CODE INSPECTION TYPE DATE INITIALS
1616 Fixed System Final Fire Prevention 206 Final Mechanical
1266 Pool Spa Final 208 Final Plumbing
200 Final Re-Roof 210 Final Electrical
201 Final Block/Retaining Wall 212 Final Fire Prevention
202 Final Factory Fire Plate 220 Final Planning Approval
203 Final Sign 222 Final Site
204 Final Demolition X 250 Final Building/Occupancy lb g U - I I E1�" �'r"
WORKERS'COMPENSATION DECLARATION: ` Owner:J verified by driver b license. ❑Yes ❑ No
I hereby affirm under penalty of perjury one of the following declarations: Driver's License No. Expires:
❑ I have and will maintain a certificate of consent to self-Insure for workers' Verification of Ownership by(type of document.i.e.-property tax bill or deed):
compensation, as provided for by section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
❑ I have and will maintain-workers'compensation insurance,as required by
section 3700 of the Labor Code, for the performance of the work for which this DIVISION OF INDUSTRIAL SAFETY PERMIT CERTIFICATION:
permit is issued. My workers' compensation Insurance carrier and policy ❑ I hereby certify that no excavation five(5)or more feet in depth into which a
number are: person is required to descend,will be made in connection with work authorized
c� by this permit,and that no building structure,scaffolding,falsework,or demolition
C@niers r / ['� OC/ or dismantlingthereof,will be more than thirty-six 36 feet high.(Chap.3.2,Grp
—(This section need not completed rf the permit Is valued at Tie hundred dollars(s100)or less) ra ( ) 9
//�� r 2,Art 2,Sec.341,Title 8,California Administrative Code).
Polic9r.Number: n( 9 r S
❑ As owner-builder, I will not employ anyone to do work which would
❑ I certify that in the performance of the work for which this permit is require a permit from the Division of Industrial Safety,as noted above, unless
issued, I shall not employ any person in any manner so as to become subject such person has a permit to do such work from the division.
to the workers' compensation laws of California. and agree that if I should
become subject to the workers' compensation provisions of Section 3700 of
Applicant's Signature Date
the L e,I shall forthWttl-comply with these provisions.
/e{ 7 7_ Division of Industrial Safety Permit Number:
Ap[Gcmca Signature HAZARDOUS MATERIALS AND EMISSIONS CERTIFICATION:
WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE 1. Will the applicant or present or future building occupant need to file and
IS UNLAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL certify a Business Plan for emergency response to release or threatened
PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS release of a hazardous material? 0 Yes 0 No
($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS (Section 25505 of the California Health and Safety Code requires, with some
PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND exceptions, that a Business Plan be filed with the Costa Mesa Fire
ATTORNEY'S FEES. Department by every business which has at any one time during a reported
year a quantity of hazardous materials equal to or greater than a weight of
LICENSED CONTRACTORS DECLARATION: 500 pounds,or a volume of 55 gallons.or 200 cubic feet of compressed gas
'I hereby affirm that I am licensed under provisions of Chapter 9(commencing at standard temperature and pressure).
with Section 7000) of Division 3 of the Business and Professions Code, and 2. Does or will the applicant or present or future building occupant need to file
my license is in full force and effect. a registration form for acutely hazardous materials? ❑Yes ❑ No
Lia#r-sQ2)sv U Cla$s•#T�" L 7 3 (Section 25533 of the California Health and Safety Code, with some
exceptions, requires registration with the Costa Mesa Fire Department by
J7-rAt%�G2�— ill�rrti g-1- /7 C�/ each business which at any one time has on hand a quantity of acutely
Contractor's Sitinarre DaW— " hazardous materials equal to or greater than a weight of 500 pounds, or a
volume of 55 gallons, or 200 cubic feet of compressed gas at standard
CONSTRUCTION LENDING AGENCY: temperature and pressure).
❑ I hereby affirm that there is a construction lending agency for the 3. Does or will the applicant or present or future building occupant need to
performance of the work for which this permit is issued.(Sec.3097,Civil Code). prepare an RMPP (Risk Management and Prevention Program for acutely
Lender's Name: hazardous materials)? ❑Yes ❑ No
(Section 25534 of the California Health and Safety Code provides that the
Lender's Address: Costa Mesa Fire Department may require the preparation. certification and
filing with the Fire Department of an RMPP by businesses which are required
to register acutely hazardous materials with the Fire Department.
Signature Date
4. If an RMPP is presently required, has Section 25534 of the California
• OWNER-BUILDER DECLARATIONS: Health and Safety Code been fully complied with? 0 Yes 0 No
I hereby affirm that under penalty of perjury that I am EXEMPT FROM THE 5. Does or will the applicant or present or future building occupant require for
CONTRACTORS LICENSE LAW for the following reason (Sec. 7031.5, the work which is the subject of this application a permit for such construction
Business and Professions Code:Any city or county which requires a permit to or modification from the South Coast Air Quality Management District or from
construct. alter, improve, demolish, or repair any structure, prior to its any other air pollution control district or agency? 0 Yes 0 No
issuance,also requires the applicant for such permit to file a signed statement (Section 65850.2 of the California Government Code requires that the requested
that he or she is licensed pursuant to the provisions of the Contractors information be fumished on applications for non-residential building permits).
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the
Business and Professions Code)or that he or she is exempt therefrom and 6. Will any part of the facility to be constructed under this permit be within
the basis for the alleged exemption. Any violation of Section 7031.5 by any 1000 feet from the outer boundaries of a school? 0 Yes 0 No
applicant for a permit subjects the applicant to a civil penalty of not more than (If yes", the facility must meet the requirement of Sections 25534 and 42303
five hundred dollars'($500).): of the California Health and Safety Code).
❑ I. as owner of the property. or my employees with wages as their sole 7. If a permit from the South Coast Air Quality Management District or other
compensation, WILL DO THE WORK, and the structure is not intended or air pollution control district or agency is required for the work which is the
offered for sale (Sec.7044, Business and Professions Code:The Contractors subject of this application, have all of the disclosures prescribed by California
License Law does not apply to an owner of property who builds or improves Health and Safety Code Section 42303 been made? 0 Yes 0 No
thereon,and who does such work himself or herself or through his or her own . 8. (If yes',attach certificate of compliance from the appropriate air pollution
employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of control officer).
completion, the owner-builder will have the burden of proving that he or she CERTIFICATE OF COMPLIANCE: I certify that under penalty of perjury the
did not build or improve for purpose of sale.). information given above is correct. I agree to comply with all state laws and
❑ I, as owner of the property, am EXCLUSIVELY CONTRACTING WITH
city ordinances regarding Hazardous Materials and Emissions.
LICENSED CONTRACTORS to construct the project(Sec. 7044, Business and
Professions Code: The contractors License Law does not apply to an owner of • Signature Date
property who builds or improves thereon,and who contracts for such project with CERTIFICATE OF COMPLIANCE AND AUTHORIZATION OF ENTRY: I
a contractor(s)license pursuant to the Contractors License Laws.), certify under penalty of perjury that I have read this application and state that
the information given is correct. I agree to comply with all state laws and city
❑ I am exempt under sec. ordinances relating to building construction, and authorize representatives of
Business and Professions Code for this reason: the City of Costa Mesa to enter upon the above-described property for
inspection purposes. I agree not to occupy or allow occupancy of any building
authorized by this permit until final inspection.
Signature of Legal Own s) Date
Signature DateretrtiCa-te2661/4
7- 7—/3057-46(3/07)
And/or Aurhodzed Applicant Date!
1 ,
I
Prescriptive Certificate of Compliance: Residential CF-IR-ALT
Residential Alte.r7ations t (Page J of 5)
. Project Name: 1 tln�( , /I ele„.22_222. ic, Climate Zone II // II of Stories
General lnformntion
Site Address: Eniureemenl Agency:/',rT!_ �/J,t t;Ji-_Late: ']
?�J V i (v• c� l 1 �t 1111 l
Building Type ogle Family 0 Multi Family Circle the From Orientation:N,E,5, W,ar degrees
Protect Type: 0 Alterations 0 Envelops 0 Fenestration ILooi 0 HVAC
Conditioned Flom Hien(CPA):
Replacement or Change Out 0 Duct Replacement 0 Water Heater
NOTE: This form is not to be used far Newly Constructed Buildings nr Additions
Insulation Values For Opaque Surfaces(for Furring use the Mass and Furring Strips Construction table below)
Assembly Alteration
•
0 Opening of framed cavity alone-Alterations that involve the opening of the fanned cavity of a wall,ceiling, or floor must install the
nlandainr'1'ntninunn insulation value per§1511 for the altered assembly.Fill in Columns A-C and enter mandatory insulation value in Column B.
0 Replacement of entire assembly-Replacement of entire vital?, ceiling,o'floorassembly requires the installation of Component
Package-D insulation values in Table 131-C. Fill in Columns A-J.
I
Opaque Surface Details For the furred portioned of Mass Walls see Furring Strips Construction Table below.
A • B C D E - F G H... ... . .7. ' ll, J .
Proposed t,e�nou Standard Values From JA4 Table
Framing Thickness, Framed Continuous J1.4 Proposed
Tag/ Assembly Name Material Spacing, U- JM Table Cavity Insulation Assembly Assembly
ID' or Type' and Size2 or Other3 1 factor" i Numbers R-value R-Value° Cell Values U-factor9
lime:For furred assemblies,accountingfor Continuous Insulation R-value,see Page JA4-3 a ndEquation 4-1. For calculatingfurred walls use the Mass and
t Furring Construction table below.
I.For Tog/ID indicate the identification name that matches the building plans.
2.Indicate the Assembly Name or type:Roof/Ceiling, Walls,Floors,Slabs, Craw?Spade,Doors and etc...Indicate the Frame type and Size: For
Wood, Metal, Metal Buildings,Mass, enter 2x4,2x6, tar etc.,, see JA4 for other possible frame type assemblies.
3. Enter the thickness for mass in inches or Spacing between framing members enter; 16"or 24"OC; or Other for all other assembly description
such as Concrete Sandwich Panel,Spandrel Panel,Logs,Straw Bale Panel and etc....
4. Based on the Climate Zone;enter the Standard U-factor from Table 1.51-B, C or D for each different assembly Name or type.
3.Enter the Table number Ihai closely resembles the proposed assembly.
6. Enter the R-value that is being installed in the wall cavity or between the framing; otherwise, enter "0".
7. Enter the Continuous Insulation R-value for the proposed assembly;otherwise, enter "O"
0.Enter the rot,'and column of the U-factor value based on Column F Table Number and enter the Assembly U-factor in Column I
9, The Proposed Assembly Lb-factor; Column 3, nasi be equal to or less than the Standard U-factor in Column E to comply, •
Furring Strips Construction Table for Mass Walls Only
A _ It • C I D 1E F .1 G Il 1 3 I< L M
Proposed Properties of Masonry and Concrete Added interior or'Exterior'insulation
• Walls From Reference in Furring Space from Reference
• Joint Appendix Table 4.3.5,4.3.6.4.3.7 Joint A tench;Table 4.3.13
;i
Tv ✓r' N f U 0 U
N 15 ci 4,U y+. :-
Assembly <"e, t .° a ~ ' e, � mN Lee e; � Final
Mass Hume et )A4 Table e in 1 7 ;, P u E R g •'E : 3 " —. . Assembl>
Thickness' 'lige' Number' _ < c ui e 4 u` e u c u c U-facto ,r Comment
•
I
nr,,,,;,.,,,,,t.,,, N,,,,,hm— Registration Date/Tim: HERS Provider:
Prescriptive Certificate of Compliant .cesidetttial CF-1R-AL,T
Residential Alterations t r (Page 3 al 5) -`. .,
!•inject Nu ne; Climate Zhu it ti Of`Starlos
ROOFING PRODUCTS(COOL ROOFS)§1510912
When the area of axtarlm•rnnfsttrfaee to he replaced exceeds more than 50%of the existing roof area, or more than 1,000 fir', whichever Is
less, the new roofing area must sneer the roofing product"Cool Roof"requirements ofc152(b)1fli, IS2(b)IHIi, or 152(b)1Hilb
Check applicable alrarrtativu or exception below If the roof alteration is exempt front the roofing product "Cool Roof"requirements. Note:If any
ane of the alternatives or exception below is checked, the Aged Solar Reflectance and Thermal Emtuance requirements for roofing products in
,§I18(I) are not applicable. Do not fill table below.
I Roofs Not Required in Climate Zones 1-12, 14,and 16 with it Low Sloped. Leas or 2:12 pitch.
ooh hofs Not Required in Climate Zones I through 9 and 16 with it Steep-Sloped Roofs(pitch greater than 2:12)and product unit weight less
than 51b/fie.
Alternatives to t 1520)1111 and §152(b)Fill,Steep-slope roof(pitch > 2:12)
❑ Insulation with a thermal resistance of at leant 025 hr•f12'77Bat or at leant a 3/4 inch air-spice is added to the roof deck
over nn attic;or
❑ Existing ducts in the attic arc insulated and sealed according to §15 1(010;or
❑ In climate zones 10, 12 and 13,with I fl2.of free ventilation area of attic ventilation for every 150 112 of attic floor area,and
where at leant 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge;or
0 Building has at least It-30 ceiling insulation;or
❑ Building has radiant barrier in the attic meeting the requirements of§151(1)2;or
❑ Building has no ducts in the attic;or
o In climate zones 10, I I, 13 and 14,R-3 or greater roof deck insulation above vented attic,
Exception to §252(h)1Hili,Low-slope. roof(pitch 52:12)
O Building has no ducts in the attic.
Other Exceptions
. o Roofing area covered by building integrated;photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria.
❑ Roof constructions that have thermal mass over the roof membrane with at least 25 Ib/ft2 is exempt from the below Cool Roof criteria.
-I Note: If no CRRC-I label is available,this compliance method cannot be used,use the Performance Approach to show compliance,otherwise,
Check the applicable box below if Exempt from the Roofing Products"Cool Roof"Requirement:
Roof Slope Product Weight Product I Aged Solar Thermal
CRRC:Product ID Number' < 2:12 >2:12 < 51b/ft2 > 51b/ft? Tyoe2 f Reflectance'" Emittance SRI5
❑ ❑ I D I ❑ 04
❑ ❑ ❑ I ❑ ❑41
❑ ❑ ❑ 0 ❑4
—
❑ ❑ ❑ El 04
❑ ❑ 0 0 ❑4
I. The CRRC Product ID Number can be obminedfr•om the Cool Roof Rating Council's Rated Product Directory at www.coolroofs.orq/products•/search.php
2. Indicate the type of product is being used far the roof top,i.e.single-ply Mgr,asphalt roof,metal roof etc.
3. If the Aged Reflectance is not available in.the.Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value front the sante
directory and use the equation(0.2+0.7(p 51,at—0.2)to obtain a calculated aged value. Where p is the Initial Solar Reflectance.
4. Check bar Ifdre Aged Re/lectatce is a calculated value using the equation above.
5. Calculate the SRI value by using the S/ti- Worksheet at luta://www,enertatca.aov/tlde24/and enter the resulting value in the SRI Column above and attach acopy of
the SRI- Worksheet to the CF-IR.
To apply Liquid Field Applied Coatings,the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
recommended by the coatings manufacturer and meet minimum performance requirements listed in§I180)4. Select the applicable coating:
❑ Aluminum-Pigmented Asphalt Roof Coating ICI Cement-Based Roof Coating ❑ Other
•
•
Registration Number: -Registration Date/Time: HERS Provider:
2008 Residential Compliance Forms • August 2009
•
Prescriptive Certificate of Compliance: Residential CP-71t-ALT
Residential Alterations (Pa 2e 5 of 5)
, Fr lice! IVnmc: Climntr Zn na it J t of Stories
•
HERS VERT]CAT1 ON SUMMARY The enforcemem agency should per special aaenrion rr.Ihr HERS Measures specified ur this
checldisi heloa. A completed and signed CF-41f Form for cd!the meaxures specified shall be slummed to the building inspector before Jinal
inspection.
Duct Sealing & Testing HERS verification is required for rhi.t measure.
D YES 0 NO 1'ES:be Climate Zones 2 and 9-1a,if more dm»46 hnear feel of new nr replacement ducts are Metalled in unconditioned
space,the ducts arc to be sealed per§152(h)1Dii and the newly installed ducts ore to be insulated per (1 S 1(f)1 0.
0 EXCEPTION:Existing duct systems than are'extended, which are constructed, insulated or sealed with asbestos.
D YES D NO YES:In Climate Zones 2 and 9-16, if'the existing space-conditioning system(HVAC equipment and ducting)is replaced,the
ducts are to be sealed per§152(h)7Di.
YES D NO YES:In Climate Zones 2 and 9-16,if the existing HVAC equipment is replaced(including the replacement of the air handler,
outdoor condensing unit of a split system,cooling or heating coil,or the furnace heat exchanger)the ducts are to be
sealed per§)52(b)1E. •
D
EXCEPTION:Duct systems that are documented to have been previously sealed confirmed through HERS
verification in accordance with procedures in the Reierenee Residential Appendix RA3.
D EXCEPTION:Duct systems with less than 4111inear feet in unconditioned space.
D EXCEPTION: Existing duct systems constructed,insulated Of sealed with asbestos.
Refrigerant Charge- Split System HERS verification is required for this measure.
D YES 0 NO YES:In Climate Zones 2 and 8-15,when the existing HVAC equipment is replaced(including the replacement of the air
handler,outdoor condensing unit of a split system A/C or heat pump,cooling or heating coil,or the furnace heat
exchanger)a refrigerant charge.measurement shall be verified per§152(blIP.
Central Fan Integrated (CFI)Ventilation System and Fan Watt Draw
The ventilation requirements of SI 50(o)do not apoly to existing residential homes.
Ducted Split Systems-Air Conditioners and Heat Pumps: Airflow' HERS verification is required for this measure.
- D YES 0 NO YES:In Climate Zones 10 through 15,when the existing space-conditioning system(HVAC equipment and ducting)is
replaced,the airflow and fan wan draw shall be verified per§152(b)1 Ci to meet the requirements of §I51(f)7B.
X03- ! -. .
Documentation Author's Declaration Statement
•• I certify that this Certificate of Compliance documentation is.accurate and complete.
Name: Signatur Signatur
11-44 U C(Sco `rlc;Nr LCA ,U11_tsr•� �Yu� .
Company: (/ Date:
1 }ec% iGe.A tie) — 7�l
Address: If Applicable D.CEA or❑ CEPE
r 2_CJa t eteC Cf CA/ (Certification 01):
City/Stayysa/Zip: Phone: •
: 0-4fL9F✓ •aa.2"6- CA raf ct (7<(1) 7Y`a
Responsibie.Btiiiding Designer's Declaration Statement
1 ant eligible.under Division 3 or the Culilorma Business and Professions Code to accept respunsibiliq- for the building design identified on
this Certificate of Compliance.
• 1 Unruly that the energy features and performance specifications for the building design identified on this Ceti-Menu:of Compliance cuniorm
to the requirements of Title 24,14ntts I and 6 of the California Code of)Regulations.
• The building design feature:;identified on this Certificate ofCumplianec arc conaistunt with the inlornmttor provider)to document this
building design on the other applicable compliance Jurane,worksheets,enIcutatione,plan:.Lind specificoion::submitted to 11w en-curaemeM
upency In: approval with this building permit application.
Name: Signature:
Company: Date:
Address: License: •
City/State/Zip: I Phone
Tor assistance or questions regarding; the Energy Standards, contact the Energy Boninr at: )-81111-772-331111.
OWNER WTT,T,TAM KT,OT7 - DATE 11-11-55
JOB ADDRESS 18214 Viola-Place- ✓ BUILDING PERMIT NO. 1119
1 GENERAL CONTRACTOR Gentosi Brothers VALUE $ 600.0o
LOT AN n6-o92-9 BLOCK TRACTEnclose porch for rumpus room
Rh
GROUP I TYPE V ZONE +W FIRE DISTRICT 1130
PERMITS ISSUED •
INSPECTIONS DATE SUBCONTRACTOR DATE NUMBER
I• Footing Trench No
.1 Foundation Forms and Grade to Garage
Rough Framing 4-i--I 4/3-S3
Plumbing, Rough to Slab
Plumbing,Rough Complete
Temporary Pole ,/ '/
Wiring, Rough -741-/ 7 •.-21:5 f E—c. eadu OE- ea V- 1 J -;
l 7/5-
Heating,Rough
Heating,Final _
Sewer, House Sewer,St.
Septic Tank or Cesspool
Lathing, In Pey /�Out /IC- '-,j1
Plastering 4-13.
Plumbing,Final,Fixtures Complete 1.--E-4�gq5--/2 -5-• •
Plumbing,Final Gas Test �d Gn£41SC+ ..4--
..yMit—Mit— : ^
Wiring,Final .S -/2 - t CatQc cC. -•--- '3 -/3--(1 IL-L`S
Occupancy —. f-./j,. .s---
Form 210 G-H 15001-55
'Posta Mesa Building DepartmenW W APPLICATION FOR PERMIW
111 EAST 20th STREET BUILDING 1
COSTA MESA, CALIFORNIA - .. ^
f ° • FOR OFFICE USE ONLY '
FOR APPLICANT TO FILL IN .Receipt No.__ - -Permit No. ,
Building Arada:rite., i I //,/7
Address
Costa Slesa, California delsecgye,d , /Date Reo'd. D to Issued
Nearest iQ
. `2te> I/` `1`yam l�`�J
Cros4 St. sa3a9r I Building / ya ^ U, 4-7 i
W m . / I I_ Q 7"'"?... Address 6
Owner /1✓rCosta Mesa, California
Mail /t, qi. u/ aA. pp
Address sL NearestrossS / K' �y
Tel. Cross St.
City No. Zone ,.,No.of I Type I Group
Architect or Lie. Plans
Engineer No. Approved
by Date
Address A CORRECTIONS
Contracto Si ,(JEOSNo.City L/ .,/ '
Address �irek v f4"
Legal Lot
Description No. I Block III Tract/If
(Attach Metes and Bounda)PPi ��Q��— f � � �
/� 1
No.of Bldgs.
Size of Lot I Now on Lot w O
Use of I No.of I No.of n ]• 1 195 71
Existing Bldg. Families Rooms ,] 3
Setback Line from' Rear Yard Z
Center of Street Side Yard . A >
DESCRIPTION OF WORK — niyy OF coSTA M!SJL
New I I Alteration I I Addition I //
V;+-,. c,:;cf
Repair I I Moving I I Demolish I .•-• ` - . ' _• ` ter
Building No.of
Size a,0 V p.0 Rooms Stories
Exterior Wall Roof
Covering ,Q 4.0,02,40 I Covering Worm oP/m1, APPROVALS
Use of New V Foundation Location Inspector Date
Forms,Materials,
4•A'C�-"e 'V Under-Pinning
Frame: Fire Stops,
��,y� Bracing,Bolts
neoleneI hereby owledge that I have read this Application Lath. Int.
and state t at the above is correct and agree to comply Lath. Ext.
with all City Ordinan` and State Laws regulating
building constructio !,
-. Plaster,Int.Signatu re of / •.
Permittee .. .. �� Y
.i1J � ' f
to — a Plaster,Ext.
Authorized Agt.
Masonry Reinforced
Valuationi® / Permit Fee $ ¢ O o
Plan Check $ SO Bond Beam
$ tl� �.. , Total
Fee $4 ,- o FINAL
cnnM nn4 a-H 2M 5-54
•
•
OWNER KLOTZ, WILLIAM -- DATE 6-9-59
JOB ADDRESS 182)4 Viola Pl. BUILDING PERMIT NO. - 77 6
GENERAL CONTRACTOR Better Built VALUE $750.00
AP. No.116-092-9 LOT TRACT FIRE ZONE DESCRIPTION OF WORK Block Wall
INSPECTIONS DATE GROUP TYPE III ZONE
Underground Soil U.G. Water _ SUBCONTRACTOR PERMITS ISSUED
Underground Gas DATE NUMBER
Overhead Water and Gas
Rough Heating
Rough Plumbing
Miscellaneous
Prop. Swr. Line House Con. St. Swr.
Sprinkling System
Heating, Final
Plumbing Fixtures
Final Gas Test
Construction Pole
Underground Power
Rough Wiring
Trenches Forms Steel t/'e ?„'27
Floor System
Steel Reinforce Chimney Re-Rod
Bond Beam
Sheathing
Frame and Flashing
Lathing, In Out
Plaster, brown coat
Plumbing Fixtures, Final
Electric Fixtures, F' al
Building, Final , fa ,�__ 1'jar ergar..
OCCUPANCY
Form 210-3M-4-59 9556
SEE RECEIVLU w
9556 • DG. .tun9
FINANCE DEPT, /959
COSTA MESA BUILDING-SAFETY DEPARTMENT CITY OF COSTA MESA
P.O.BOX 317 COSTA MESA, CALIFORNIA
a
• FOR APPLICANT TO FILL IN COMPLETELY APPLICATION FOR PERMIT
/S�R � TYPE OR PRINT BUILDING
ADD LDEISS/ /•/ Y Oct-a_ 7 2
COSTA MESA, CALIFORNIA FOR OFFICE USE ONLY
,yee, RECEIPT NO.
(Q
OWNER //( IPL ✓
JJ�
MAIL RECEIVED BY DATE RECEIVED I DATE ISSUED
ADDRESS/ 5, 171 � / /s/ �y
CITY /2q ,Y,�L TND.Lf'Q viu BUILDING
ADDRESS
ARCHITECT LIC. COSTA MESA. CALIFORNIA
OR ENGINEER NO. FRE „ r 7
-
ADDRESS
1 ZONE
/O/ OjBPR
APPROVED
CONTRACTORD 4/„ 4,y LIC.NO. /OYDATE
ADDRESS 55/2 -.4,f14O -X Y/, ZONING
LEGAL 'LOT I ZONE p INO.OF IUSE OF NEW �)
'K``/ PLANS
BUILDING /V/A/J'/
DESCRIPTION N/O./ ( BLOCK /� I TRACT /Y, o�J/q�/1/y�/ /y'
A.P.NO. //( (� '� 0/ / i APPROVED //�'/!� `� DATE / U v�
NO.OF
OF LOT V D�/[JO I NOW ON LOT6 YARDS
REQUIRED ` EVES
ALLOWED ///
USE OF (CENTER LINE ST.) a
EXISTING BLDG. FRONT p L�
SETBACK LI STLINE FET SOY
NY REAR YARD •2” R.SIDE --1 FT. IN.
CENTER OF STREET DLJ/
SIDE YARD I LEFT A -, RIGHT Ae L.SIDE ffr. FT. IN. '
DESCRIPTION OF WORK
REAR FT. IN.
NEW /lI I ALTERATION I II ADDITION 1 ai,--. .4.C_ ,i(�/ C a•
REPAIR I II MOVING I II DEMOLISH I
BUILDING NO.OF
SIZE ROOMS STORIES
EXTERIOR WALL (ROOF •
= COVERING COVERING '
USE OF(BUILDING AND WORK TO BE PERFORMED
,� O 7 BU �4 L/ �/NU'
1 HEREBY NEDGE THAT //HAVE READ THIS APPLICATION THE AMOUNT SHOWN UNDER VALUATION IS FOR THE
AND STATE THATT THE ABOVE JS.- ORRECT AND AGREE TO COM PURPOSE OF ESTABLISHING A PERMIT FEE ONLY.
PLY WITH ALL CITY ORDINANCE AND STATE LAWS REGULATING
BUILDING CONSTRU'CTIO ./ VALUATION
ate
SIGNATURE OF // /', PERMIT FEE $ �w
PERMITTEE
$
ii i K ,i
.5•22 PLAN CHECK $
i AUTHORIZED AGENT TOTAL FEE $ 6 . K79
Cana Mesa BuildingDepartment /n� %APPLICATION FOR FERMIS
-`' -;4.. 111 EAST 20th TREE 12138 - BUILDING '
,. , COSTA MESA, CALIFORNIA �..GG! v
FOR OFFICE USE ONLY
FOR APPLICANT TO FILL IN _ - . ._- Receipt No.__- Permit No.
Building N ge� /dJJ 2—, - /1//9 + /0 2./ •
Address t
CO5 Mesa, California Received by Date Rec'd. {tIII Date Issued +
Nearesty I /7
Cross St. J 8 '^" - Building
/� Address ,.
Owner I�4- Costa Mesa, California
Mail / 124 1 Be
ddress /,SJCO'� .�l(AL Nearest
jj'�J _� �,,�� ))�� Tel. Cross St. r p r a r•.-
City (_-„QaC1Jie. Meat: No. Zone r/' I No.of I Type i , ` l+Group 1
Architect or F tic. �-• Plans 1/
Engineer No. Approved
by Date
Address •
CORRECTIONS
/� City L'c,
Contractor Azo$i No. 1 ,2,
Address { % /(2ldw-s3' ”' -
LegalLot I ,,p�
Description I No. j I Block I Tract4 _
(Attach Met/es and Bounds) ®r - ,
No.ofSize of Lot LOX /35 I Now on Loncits / �
Use of }� ��._ No.of No.of :ri, 17 145 • z
Existing Bldg. hi' Q, Families Rooms 1 - -- �,
Setback Line from gc ige e o Rear Yard
Center of Street - •µ1�/LC!(J Side Yard - y
DESCRIPTION OF WORK CITY OF COSTA MESA
New I hi Alteration I I Addition I ,
Repair I I Moving I Demolish I - -
Building ' i No.of %
Size Z19a"�"�` Rooms
Stories
Coverin , Cn I Roof Ke, APPROVALS
CoveringCoverin
Use of New
Foundation Location
J}!/Z,*me $;inspector Date
Building J
Forms,Materials, a
Under-Pinning
Frame: Fire Stops, --I
Bracing,Bolts n to
Lath. Int. a�j r,r, =' o
I hereby acknowledge that I have read this Application a _ -
and state that the above is correct and agree to comply 7 -I :21,2
with all City Ordinances and State Laws regulating Lath.Ext. �n 5 _
building construe.. . l
Signature of
�- Plaster,hit. r o
Permittees' - ={;- I `r Io FE
Plaster,Ext. +. ,n
Authorized Agt. /1! In
*
Masonry Reinforced *
Valuation 1■, Permit Fee $ f r :f
Plan Check $ Bond Beam -E No
'Sob Total O _ o4/L .� ,,STT-r _
Fee $ }f FINAL O C� - p
7}
CORM 204 G-H 2M-5-54 _
OWNER KL01Z, WILLIAM / DATE 3-17-55
JOB ADDRESS 1824 Viola Place ` / BUILDING PERMIT NO. 1021
GENERAL CONTRACTOR Gentosi Bros. V VALUE $ 6,200.00
LOT 7 BLOCK TRACT 1148 Dwelling 'q
GROUP I TYPE V ZONE R1..{ FIRE DISTRICT 1038
PERMITS ISSUED
INSPECTIONS DATE SUBCONTRACTOR ._
DATE NUMBER
Footing Trench , I c. 3-23-s c
Foundation Forms and Grade Gara 1, -; —3
i
Rough Framing —i i0+*
Plumbing,Rough to SlabSo ' t —�/ '/-
Plumbing, Rough Complete 7liL/0 7" .r r "y), �v a it -T-0s:S\ Ks-if 7
Temporary Pole _ 9/S
Wiring, Rough GGG,5 .1-8-.15 i - - _ _. . 4-P-SSS e9/
Heating,Rough
Heating,Final `P. ...�//.,,t Z is—L /d--27
,/Sewer, House //Sewer,St.j/jS/SY '' `f nrf, iy'J/ 2_ � -s._cS— /(--'2 4.4
Septic Tank or Cesspool
Lathing, In X Out r/;- 4 -11,41
Plastering
Plumbing,Final,Fixtures Complete
Plumbing,Final Gas Test
Wiring,Final r� / - _
Occupancy �vt, //� SI
F'nrm 210G-111500 1-55